Download presentation
Presentation is loading. Please wait.
1
TIA Portal V12 Одна среда для инжиниринга
Totally Integrated Automation Portal для SIMATIC STEP 7 и SIMATIC WinCC. Project download New functions TIA Portal views Totally Integrated Automation Portal Live-Demo Anmerkung: StartDrive ist in STEP 7 Professional V12 ab dem SP 1 kostenfrei enthalten. STEP 7 V12 WinCC V12 Startdrive V12 SIMATIC Controller SIMATIC HMI SINAMICS STEP 7 + WinCC =TIA Portal
2
TIA Portal V12 Overview of the scope of the products
SIMATIC STEP 7 V12 SIMATIC WinCC V12 Programming languages LAD, FBD, SCL, STL*), S7-GRAPH**) Machine level HMI SCADA applications *) S7-300/400/1500/WinAC **) S7-300/400/WinAC WinAC (incl. Failsafe) Professional NEU S (incl. Failsafe) SCADA Professional S7-400 (incl. Failsafe) PC Single station Advanced S ET 200 CPU, (incl. Failsafe) Comfort Panels and X77 und Mobile (no Micro) Comfort S7-1200 Basic Basic Panels Communication PROFIBUS, PROFINET, AS-i, IO-Link, ET 200, network topology Shared functions system diagnostics, import/export to Excel, undo, …
3
TIA Portal V12 Basics
4
TIA Portal V12 TIA Portal V12 Project download New functions
TIA Portal views Live-Demo
5
TIA Portal V12 What is the Totally Integrated Automation portal?
The Totally Integrated Automation Portal provides the work environment for end-to-end engineering with SIMATIC STEP 7 V11 and SIMATIC WinCC V11. Centralized engineering framework A common user interface concept for all automation tasks with common services (e.g. configuration, communication, diagnostics) Automatic data and project consistency Powerful libraries across all automation objects Several Engineering systems Project download New functions TIA Portal views Live-Demo Combined in one Framework
6
TIA Portal V12 Intuitive – efficient – future-proof
Intuitive: Easy to learn – Easy to use with task-oriented, intelligent and intuitive editors Efficient: Efficient engineering with an end-to-end engineering framework for all automation tasks Future-proof: Reuse existing automation solutions and integrate future software products in the TIA Portal engineering framework Project download End-to-end engineering New functions Totally Integrated Automation Portal TIA Portal views Control HMI Drives Live-Demo Networks … Totally Integrated Automation Portal Usability Interoperability & openness Solid foundation for future innovations
7
Drive technology in TIA Portal
TIA Portal V12 Overview SIMATIC STEP 7 V12 SIMATIC WinCC V12 SIMATIC StartDrive V12 Programming languages LAD, FBD, SCL, STL*), S7-GRAPH**) *) S7-300/400/1500/WinAC **) S7-300/400/WinAC HMI + SCADA applications Drive technology in TIA Portal WinAC (incl. Failsafe) Professional NEU S (incl. Failsafe) SCADA Professional S7-400 (incl. Failsafe) PC Single station Advanced S ET 200 CPU, (incl. Failsafe) Comfort Panels and X77 und Mobile (no Micro) Comfort G120 CUxxx-2 V4.5 StartDrive V12 S7-1200 Basic Basic Panels G120 CUxxx-2 V4.4 Communication PROFIBUS, PROFINET, AS-i, IO-Link, ET 200, network topology Shared functions system diagnostics, import/export to Excel, undo, …
8
SIMATIC STEP 7 V12 End-to-end engineering for all SIMATIC controllers
Engineering Optionen STEP 7 Safety V12 TIA Portal V12 § Virtualisation Easy Motion Control V12 § Languages § Installation PID Professional V12 Project download New functions Engineering Edition STEP 7 Professional V12 TIA Portal views nicht für S7-1200 nicht für S7-1500 Live-Demo STEP 7 Basic V12 Device S7-1200, Basic Panels ET 200 CPU, S7-300, S7-400, WinAC S7-1500
9
SIMATIC STEP 7 V12 Options for STEP 7
TIA Portal V12 STEP 7 V5.X STEP 7 Professional V12 § Virtualisation Integrated Options for STEP 7 § Languages § Installation SCL SCL Project download GRAPH GRAPH New functions PLCSim PLCSim DocPro DocPro TIA Portal views Teleservice Teleservice Live-Demo CFC Distributed Safety STEP 7 Safety Easy Motion Control Easy Motion Control Modular PID Standard PID PID Professional PID Selftuner D7-SYS PDIAG S7-Technology
10
SIMATIC STEP 7 V12 STEP 7 Professional V12
TIA Portal V12 Migration of STEP 7 V5.5 / Professional 2010 projects is possible: IEC Languages LAD, FBD, SCL, STL, GRAPH Hardware / Network Configuration (dead line !) New concepts in future versions for: Process Diagnostics H-Systems Migration is not planned for: HiGraph IMap FMS connetions WinAC S7-1500 S7-400 S7-300 S7-1200 § Virtualisation § Languages § Installation Project download New functions TIA Portal views Live-Demo
11
SIMATIC WinCC V12 End-to-end engineering from Panel to SCADA
TIA Portal V12 Engineering Edition WinCC Professional 512, 4k, max. PowerTags § Virtualisation § Languages § Installation WinCC Advanced Project download New functions WinCC Comfort TIA Portal views WinCC Basic Live-Demo Geräte Basic Panels Comfort Panels, Mobile Panels Panel PC, Standard PC SCADA Single Station … based on WinCC flexible RT SCADA System … based on WinCC V7 Runtime
12
SIMATIC WinCC V12 Optionen
TIA Portal V12 WinCC flexible WinCC (TIA Portal) WinCC § Virtualisation Option for RT Advanced / Panels Option for RT Professional § Languages Integriert § Installation Archives Logging Logging ArchivPowerpacks Project download Recipes Recipes Recipes UserArchives New functions Audit Audit Audit Client Client TIA Portal views Server Server Redundanz Live-Demo CAS WebNavigator WebNavigator DataMonitor DataMonitor DowntimeMonitor CalenderScheduler ProAgent ProAgent W.OLEDB OPC Connectivity Pack OPC Server IndustrialDataBridge CAL RT API Change Control ODK SIMATIC Logon SIMATIC Logon SIMATIC Logon CDK OPP ControlDevelopment (PC) IndustrialX
13
SIMATIC WinCC V12 Simple engineering even for complex applications
TIA Portal V12 By integrating SCADA in the TIA Portal the user benefits from its excellent usability Large data volumes such as tags or alarms can be generated quickly in grid editors Everything at a glance with an object-oriented approach, e.g. edit alarms directly at the tag Intellisense and code templates for scripting New functions for SCADA System functions like SetBitInTag Simple dynamics configurable e.g. horizontal movement Configuration of events direct at alarms § Virtualisation § Languages § Installation Project download New functions TIA Portal views Live-Demo
14
SIMATIC WinCC V12 New functionality - Highlights
TIA Portal V12 Engineering Symbolic addressing in context of S – also in engineering and runtime Optimization of the faceplate technology New library objects Time synchronization – easy to realize IP-address configuration for panels via engineering system Runtime F(x) Control – for Comfort Panels and Runtime Advanced Enlargement of recipes – upload of data records back to the engineering system New communication driver (Mitsubishi MC TCP/IP, Allen-Bradley EtherNet/IP) § Virtualisation § Languages § Installation Project download New functions TIA Portal views Live-Demo
15
TIA Portal V12 Supported operating systems (directe installation)
Engineering Software StartDrive V12 WinCC Advanced / Professional V12 STEP 7 Professional V12 WinCC Basic V12 STEP 7 Basic V12 Betriebssysteme 32bit + 64bit WinXP Home SP3 Windows 7 (Home, Premium SP1) WinXP Professional SP3 Windows 7 (Prof. / Enterprise / Ultimate SP1) Windows Server 2003 StdE SP2 Windows Server 2008 R2 StdE
16
TIA Portal V12 Virtualisation (supported hypervisors)
Supported virtualisation software Supported TIA Portal V12 versions STEP 7 Basic/Professional V12 VMware vSphere Hypervisor ESX(i) 4.1, 5 WinCC Basic/Comfort/Advanced/Professional V12 VMware Workstation 8 StartDrive V12 VMware Player 4 Microsoft Windows Server 2008 R2 SP1 Hyper-V WinCC Runtime Advanced V12 WinCC Runtime Professional V12 or later versions Host operating systems Guest operating systems Windows 7 (Business / Ultimate) 32-bit bit Windows 7 (Professional / Business / Ultimate) 32-bit + 64-bit Windows Server 2008 R2 64-bit
17
TIA Portal V12 Multi language support for worldwide use
The graphical user interface can be switched between several languages: German English French Spanish Italian STEP 7 V12: Comments (for blocks, tags, modules, etc.) can be translated and stored in several languages within the project. Using S and S comments can be downloaded to the PLC in a selected language together with the project. WinCC V12: Messages, text in screens can be created in several languages § Virtualisation Russian Korean Japanese Chinese simplified § Languages § Installation Project download New functions TIA Portal views Live-Demo
18
TIA Portal V12 „side-by-side“ installation
WinCC V12.0 STEP 7 V12.0 Basic Comfort/ Advanced Professional Runtime Advanced Runtime Professional STEP 7 Classic STEP 7 Professional 2010 SR2 (V5.5 SP2) OK STEP 7 Micro/Win V4.0 SP2 WinCC flexible (classic) WinCC flexible 2008 SP2 WinCC flexible Runtime 2008 SP2 WinCC flexible 2008 SP3 WinCC flexible Runtime 2008 SP3 WinCC (classic) WinCC RC V7.0 SP3 x WinCC RT V7.0 SP3 WinCC RC V7.2 WinCC RT V7.2 WinCC V11 WinCC Basic/Comf/Adv V11 WinCC Runtime Advanced V11 UP WinCC Professional V11 X WinCC Runtime Professional V11
19
TIA Portal V12 TIA Portal V12 Project download New functions
TIA Portal views Live-Demo
20
Project download to PLC
TIA Portal V12 Project download Download § PLC § Panel § SCADA New functions TIA Portal views Live-Demo S7-1200 S7-300 / S7-400 S7-1500 STEP 7 Professional V11 project OK X STEP 7 Professional V12 project (V11 compatible) STEP 7 Professional V12 project
21
Project download to PLC
Engineering V11 ES V12 ES V11 project V11 project (compatible) V12 project S7-1200 S7-300 S7-400 S7-1500 PLC
22
Project download to PLC
Engineering V11 ES V12 ES V11 project V11 project (compatible) V12 project S7-1200 S7-300 S7-400 S7-1500 PLC
23
Project download to PLC
Engineering V11 ES V12 ES V11 project V11 project (compatible) V12 project S7-1200 S7-300 S7-400 S7-1500 PLC
24
Project download to runtime HMI Panel
TIA Portal V12 Project download Download § PLC § Panel § SCADA New functions TIA Portal views *1 := Downgrade RT *2 := Upgrade RT Live-Demo WinCC flexible RT RT V11 RT V12 WinCC flexible 2008 SP3 project OK *1 WinCC Advanced V11 project *2 WinCC Advanced V12 project (V11 compatible) WinCC Advanced V12 project (projected RT V11) (projected RT V12)
25
Project download to runtime HMI Panel
Engineering V11 ES V12 ES V11 project V11 project (compatible) V12 project HMI V11 Version HMI V11 Version HMI V11 Version HMI V12 Version HMI V11 HMI V12 HMI Runtime := Downgrade RT
26
Project download to runtime HMI Panel
Engineering V11 ES V12 ES V11 project V11 project (compatible) V12 project HMI V11 Version HMI V11 Version HMI V11 Version HMI V12 Version HMI V11 HMI V12 HMI Runtime := Downgrade des RT
27
Project download to runtime HMI Panel
Engineering V11 ES V12 ES V11 project V11 project (compatible) V12 project HMI V11 Version HMI V11 Version HMI V11 Version HMI V12 Version HMI V11 HMI V12 HMI Runtime := Downgrade der RT
28
Project download to runtime HMI Panel
Engineering V11 ES V12 ES V11 project V11 project (compatible) V12 project HMI V11 Version HMI V11 Version HMI V11 Version HMI V12 Version HMI V11 HMI V12 HMI Runtime := Upgrade RT
29
Project download to runtime SCADA
TIA Portal V12 Project download Download § PLC § Panel § SCADA New functions TIA Portal views Live-Demo WinCC V7.x RT WinCC RT Professional V11 WinCC RT Professional V12 WinCC V7.x project OK x WinCC Professional V11 project WinCC Professional V12 project (V11 compatible) WinCC Professional V12 project X
30
Project download in runtime SCADA
Engineering V11 ES V12 ES V11 project V11 project (compatible) V12 project V7.x V11 V12 SCADA Runtime
31
Project download in runtime SCADA
Engineering V11 ES V12 ES V11 project V11 project (compatible) V12 project * ES needs to be installed on two seperate PCs * V7.x V11 V12 SCADA Runtime
32
Project download in runtime SCADA
Engineering V11 ES V12 ES V11 project V11 project (compatible) V12 project V7.x V11 V12 SCADA Runtime
33
TIA Portal V12 TIA Portal V12 Project download New functions
TIA Portal views Live-Demo
34
Installation Record function
Record function (config-file) STEP 7 V12 WinCC V12 > setup.exe /record Install.rec Or via the user interface Startdrive V12 Command line installation (Silent-Installation) > setup.exe /qb {parameter} > setup.exe /qn {parameter} with progress bar without progress bar STEP 7 V12 WinCC V12 Startdrive V12
35
TIA Portal V12 Reference projects
Project download Reference projects: New functions Open different projects as reference project § Record function § Referenz projects Open blocks of reference projects § Archive § Library Editing blocks of reference projects § Backups § Shotcuts Open reference project (more than one) Copy objects from the reference project (only for the same project types possible, e.g. V12 reference project to V12 main project) TIA Portal views Live-Demo Clue: Elements with grey background are „read only“ Double click in details view to open the blocks
36
TIA Portal V12 Archive / Retrieve
Restructure project Usual folder Archive Minimize Compress Restructure project Delete of RT data Compress .zap12 format (WinZip) Retrieve Decompress
37
News for S7-300/400 PLCs Libraries (compatibility mode)
TIA Portal V12 TIA Portal V12 Project download New functions V11 project V12 project § Record function § Referenz projects Object Object § Archive § Library § Backups § Shotcuts TIA Portal views Live-Demo V11 library V12 library Type Type Master Master Upgrade
38
News for S7-300/400 PLCs Online backup
TIA Portal V12 TIA Portal V12 Classic PLC (S7 300/400) Project download New functions Project data § Record function HW Config § Referenz projects Binary Code HW Config § Archive SW Blocks SW Blocks § Library § Backups :00 Binary Code HW Konfig SW Blocks Backup Restore Tags § Shotcuts TIA Portal views Wacht table Live-Demo Online Backups Possible since: >STEP 7 V11 SP2 Update 4 :00 Binary Code HW Konfig SW Blocks Complete HW Config + Blocks can be Saved and restored as binary code :00 Binary Code HW Konfig SW Blocks
39
Neuerungen in V12 für Classic PLCs Download Programm zur Memory Card
TIA Portal V12 Project download New functions § Record function § Referenz projects § Archive § Library § Backups § Shotcuts TIA Portal views Live-Demo
40
News in V12 Shortcuts TIA Portal V12 Overview over the shortcuts in the project settings Project download New functions § Record function § Referenz projects § Archive § Library § Backups § Shotcuts TIA Portal views Live-Demo
41
License SIMATIC STEP 7 V12 TIA Portal V12 Customer bought a STEP 7 V12 upgrade license (STEP 7 Classic -> V12) STEP 7 V5.4 / STEP 7 Professional 2006 and STEP 7 Professional V12 (TIA Portal) could be used Customer bought a STEP 7 V12 upgrade license (V11 -> V12) STEP 7 V11 and STEP 7 V12 could be used. Classic can only be used if and upgrade vom Classic to V11 was done previously Customer bought a STEP 7 V12 floating license Only STEP 7 V12 could be used Option packages of classic STEP 7 An upgrade for the option packages must be purchased Project download New functions § Record function § Referenz projects § Archive § Library § Backups § Shotcuts TIA Portal views Live-Demo
42
Licensing Combo License - Upgradeverhalten
License Key (LK) for STEP 7 Prof and 2006 Same behavior with WinCC STEP 7 Prof. 2006/2010 Classic Upgrade STEP 7 Prof. 2006/2010 STEP 7 Prof combo V11 License Key (LK) for V11 and following Classic versions (2012, 2014, etc.), if classic versions will be available License Key (LK) only for V11 STEP 7 Prof. combo V11 STEP 7 Prof. V12 Upgrade STEP 7 Prof. 2006/2010 STEP 7 Prof combo V11 Upgrade STEP 7 Prof combo V11 STEP 7 Prof combo V12 Upgrade STEP 7 Prof V12 STEP 7 Prof V12 STEP 7 Prof. combo V12 STEP 7 Prof. V12 License Key (LK) only for V11 and V12 License Key (LK) for V12 and V11 and following Classic versions (2012, 2014, etc.), if classic versions will be available Note: If the customer buys a STEP 7 Prof V12, he is able to use V11. Without bying an Upgrade
43
Licensing Exception STEP 7 Basic and WinCC Basic
Who? (Single Lizenz Basic V11) All STEP 7 Basic V11 or WinCC Basic V11 and V11 SP1 installations All STEP 7 Basic V11 or WinCC Basic V11 and V11SP1 installations that have been upgraded to SP2, without using the „Update Basic V11 Single -> Floating License“ How? Installation of the V12 Upgrade on the same computer: No problem: Single license key will be identified an da V12 Basic License will be created Installation an a new computer (e.g. with 64-bit operating system): The license must be used on the old computer and then being transferred via USB or Network to the new computer. !
44
Lizenzierung STEP 7 Basic V11 / WinCC Basic V11
TIA Portal V12 Standard license keys Floating license key for STEP 7 Basic V11/ WinCC V11 Installation of STEP 7 / WinCC Basic V11 SP2 32-Bit operating system Kunden mit vorhandener STEP 7 Basic V11 oder WinCC Basic V11 Installation benötigen nur das Update auf SP2, da der License Key noch von der V12 Installation auf dem System vorhanden ist. 64-Bit operating system Kunden mit vorhandener STEP 7 Basic V12 oder WinCC Basic V11 Lizenz benötigen folgendes Update Paket: STEP 7 Basic V11 Single -> Floating License Paket WinCC Basic V11 Single -> Floating License Paket Paket enthält Software DVD und USB Stick mit Lizenzschlüssel Project download Lieferumfang ab SP2: STEP 7 Basic V11 oder WinCC Basic V11 DVD V11 SP2 Certificate of License Lizenzschlüssel New functions § Record function § Referenz projects § Archive § Library § Backups § Shotcuts TIA Portal views Live-Demo
45
TIA Portal V12 Portal view and Project view
Workflow oriented view Faster project initial steps through simple and intuitive operation Project view: Hierarchical organization of the project All editors, parameters and data are available in the same view Project download New functions § Record function § Referenz projects § Archive § Library § Backups § Shotcuts TIA Portal views Live-Demo
46
TIA Portal V12 Portal view – fast and simple to operate
Easy to use - Portal for a fast workflow oriented start Project download New functions Accessing tasks using TIA Portal structured menus An overview of the first steps towards the realization of automation tasks On the Portal View, the operator is guided through the menu to the different tasks – e.g.: The programming of blocks Different tasks Actions of the selected tasks Selection window for correspondent action § Record function § Referenz projects § Archive § Library § Backups § Shotcuts TIA Portal views Live-Demo
47
TIA Portal V12 Project view – all editor in one window
Project view – all objects of the project in a hierarchical structure Project structure Task Cards (depending on the used editor) Working area Details view Inspector window (properties of the selected object)
48
TIA Portal V12 Individual arrangement of the working area
Maximal area for working – individual arrangement of the windows Project download New functions Working area § Record function § Referenz projects float enlarge embedding Split horizontal Split vertical § Archive § Library § Backups § Shotcuts TIA Portal views Live-Demo
49
TIA Portal V12 TIA Portal V12 Project download New functions
TIA Portal views Live-Demo
50
TIA Portal V12 Window layouts
Work with individual window layouts for more effectivity and clarity Project download New functions TIA Portal views § Layout Save individual window layout Live-Demo Management of window layouts Reset current window layout to stored configuration Selection of existing window layouts
51
TIA Portal V12 Create and manage individual window layouts
Select
52
TIA Portal V12 Editor in foreground with split work area
Keep the editor in the foreground During work with split work area it is possible to lock one editor window into position by using the paper clip button. Project download New functions TIA Portal views § Layout Live-Demo This window shows the editor to be opened locked into position
53
TIA Portal V12 SP2 TIA Portal V12 TIA Portal V12 Project download
New functions TIA Portal views Live-Demo
54
Configuring with TIA Portal
Demo Live Live Demo Sequence Open and check reference Show “Library view “ Show new features in the settings Show “Paper clip“ for split view
55
Efficient programming
TIA Portal V12 Office features for efficient programming Project download New functions Office features in V12 Autofill: e.g. in PLC tags e.g. in data blocks e.g. in HMI TIA Portal views Live-Demo
56
Efficient programming
TIA Portal V12 Copy and paste of program code Project download New functions Efficient programming Favorites bar Gather your favorite functions in the favorites bar No search for the instruction Greater working area after minimizing the tast card area Fast change of coils TIA Portal views Live-Demo
57
Office-Features in TIA Portal
TIA Portal V12 Save all changes of the project with one click Project download New functions Saving your project Data of all editors will be save by one click It is possible to save your project at any time. Even if your project contains errors. TIA Portal views Live-Demo Errors in program code
58
Windows Look & Feel in TIA Portal
TIA Portal V12 Different views for the user Project download New functions „Overview“ Look and feel like the windows explorer Folder elements are displayed in seperate sections It is possible to split the editor window: e.g. for copy of program blocks TIA Portal views Live-Demo
59
Grouping in project navigation
TIA Portal V12 Easy and fast grouping of stations or blocks Project download New functions Structure of you program blocks Seperation of technological functions Tip: Used names have to unique in groups of the same type! TIA Portal views Live-Demo Grouping of stations Grouping of blocks
60
Undo and Redo in TIA Portal
Undo in TIA Portal: Drop down menue for better control of the undo function Closed editors will be opened automatically Prject will remain consistent Undo more aktions at once
61
Devices & networks Netzsicht Netzsicht Gerätesicht Gerätesicht
TIA Portal V12 Fast and easy configuration of you station and network Project download Graphic interface for hardware and networks Configuration via drag&drop Realistic view of the hardware Diagnostic indicators in the online view All stations in one projects Connect the different stations by using the mouse Topologiesicht Gerätesicht Netzsicht New functions Gerätesicht Topologiesicht Netzsicht TIA Portal views Live-Demo
62
Consistent project data in TIA Portal
TIA Portal V12 Common database for all editors Project download New functions Common database for all editors Change of data is automatically updated in the whole project Tags will be created and assigned automatically It is possible to assign tags to hardware via drag&drop Define tags in the tag table Use in HMI editor “Run” TIA Portal views Live-Demo Define tags in program editor Show in hardware editor
63
Online & Diagnostics All editors will be updated in online mode
TIA Portal V12 All editors will be updated in online mode Project download New functions State of the PLC Online mode Current state of the project (e.g. errors, online-offline differences) Current state will be shown in each editor TIA Portal views Live-Demo View of differences
64
Online & Diagnostics – Wach tables
Drag & Drop for watch tables Create a watch table Insert manually Drag & Drop out of: Program code Data blocks Details view
65
Zusammenspiel von Controller und HMI
Short time-to-market TIA Portal V12 Project download New functions TIA Portal views Live-Demo Zusammenspiel von Controller und HMI Reducing total cost of ownership
66
Integration of controller and HMI – HMI project
TIA Portal V12 Easy to use – same look & feel for all devices Project download New functions The work with different editors runs smoothly because of their identical design Basic arrangement of the editors in TIA Portal is always identical The complete project structure is visible at all moments Properties and information are always in the same location Dynamic adjustment to the selected editors TIA Portal views Live-Demo
67
Integration of Controller and HMI – Drag & Drop of variables
TIA Portal V12 Simple and intuitive steps for a quick project creation Project download New functions HMI and Controller interact smoothly Drag & Drop of symbols and variables between: Device view and program editor (symbol is automatically generated) Device view and HMI screen Program editor and HMI screen Tag table and HMI screen Uniformly displayed: Variables are identical on the controller and HMI Automatic match of variables TIA Portal views Live-Demo
68
Integration of Controller and HMI – project wide cross-reference
TIA Portal V12 Project-wide cross-reference for a quick overview Project download New functions TIA Portal views The project-wide cross-reference provides an overview of locations where variables and objects are being used Live-Demo The cross-reference is at all times up to date All locations where an element is being used are comprehensively presented On the cross-reference list the user can jump with one click to the location where the element is being used. The correspondent editor is then opened and the element automatically selected Cross-reference for local variables
69
Compile / Download in TIA Portal
New: Detailed explanation of the compile options Different options depending on the focus in project navigation
70
Download properties – same Look & Feel for all devices
Download properties – one button for all devices – depending on the selection Offline projected device Offline projektiertes Gerät Interface Schnittstelle Erreichbare Geräte accessible devices Online status information Online Status Informationen
71
Simulation in TIA Portal – same Look & Feel for all devices
Start of the simulation – one button for all devices – depending on the selection Simulation in TIA Portal: The simulation to be started depends on the selection: E.g.: PLCSIM when a PLC is selected E.g.: HMI simulation when a HMI device is selected In case of an HMI simulation, the desired screen can be directly selected
72
Thank you for your attention!
I IA AS S SUP FA Gleiwitzer Str. 555 90475 Nürnberg Phone: +49(911)
Similar presentations
© 2025 SlidePlayer.com Inc.