Presentation is loading. Please wait.

Presentation is loading. Please wait.

A Project to Characterize The Effects of Transient Air Pollutants on the Health of African-Americans in Atlanta, Georgia John H. Hall Morehouse College.

Similar presentations


Presentation on theme: "A Project to Characterize The Effects of Transient Air Pollutants on the Health of African-Americans in Atlanta, Georgia John H. Hall Morehouse College."— Presentation transcript:

1 A Project to Characterize The Effects of Transient Air Pollutants on the Health of African-Americans in Atlanta, Georgia John H. Hall Morehouse College

2

3

4

5 Indoor Exposure and Health Effects Pulmonary and cardiovascular health Asthma Ischemic Heart Disease

6 1)To investigate the nature of transient pollutants in metro Atlanta and their concomitant effect on the health of African-Americans residing in the central city; 2)To provide, for the first time, a high time resolution and extended period speciated measurement of the spatial distribution of Atlanta fine aerosols (PM2.5, particulate matter with aerodynamic diameters less than 2.5 microns); 3)To develop the experimental expertise to identify differences in indoor and outdoor pollutant concentrations and factors that influence those differences; The Objectives

7 4)To examine personal exposure to particulate and other pollutants in a homogeneous population, by identifying very short-term exposure excursions in cardiovascular-related morbidity and mortality using real-time measurements. 5)To examine the relationship between the effects of airborne pollutants on this homogeneous sample population and effects of airborne pollutants on the heterogeneous population at large. 6)To assess the impact of short-term changes in air pollution levels on pulmonary and cardiovascular health. The Objectives

8 Three Year Project In Year 1, we propose studying an African-American population district in central Atlanta. In Year 2, monitoring would be moved to an area in southeast Atlanta, also predominantly African- American, in conjunction with a detailed monitoring program to be undertaken at the South Atlanta Environmental Protection Division monitoring site. In Year 3, monitoring will be moved to a site in Tucker, Georgia, in east of Atlanta, an area with a predominance of non-minority residents. A similar air pollution monitoring program is in place in this area.

9 Instrumentation Pulsed Infrared Laser Spectroscopy /Ion Chromatography (PILS/IC, developed at GA Tech) Organic Carbon/Elemental Carbon analyzer (OC/EC) Tapered-Element Oscillating Microbalance (TEOM) Short-Time Resolution Ion Chromatography (IC)

10 Instrumentation The PILS-IC, provides measurements of 11 different fine aerosol ionic species at a time resolution of 15 minutes with a lower detection limit of about 50 ng/m3. Organic Carbon/Elemental Carbon (OC/EC) Aerosol Analyzer - organic and elemental carbon (OC/EC) in situ Tapered-Element Oscillating Microbalance (TEOM) apparatus sampling airstreams in five-minute intervals alternating from indoors to outdoors. Short-time resolution ion chromatography-based system - to collect five-minute-averaged data on sulfate and nitrate concentrations utilizing a similar alternating indoor and out sampling protocol.

11 TEOM®1PM2.5 Dry Mass1 hour Sunset Labs OC/EC 1Total organic (non – speciated) and elemental carbon 1 hour repeated every 2 hours InstrumentQuantitySpecies MeasuredSampling Rate PILS/IC1Nitrate, sulfate, ammonium, chloride, sodium, calcium, potassium, magnesium, light organic acids 15 minutes Table 1: Instrumentation for a Ground-Based Outdoor Continuous Aerosol Speciation Monitoring Site

12 Figure 1. Mass balance of fine aerosol in Atlanta. Dry PM2.5 (preheated to 50°C) is compared to the sum of the OC x 1.4, EC, sulfate, and ammonium. The top plot shows the percent difference between this sum and the measured total mass. The agreement between these independent measurements attests to the accuracy of the various speciated measurements.

13 Figure 2. Chemical composition of the fine aerosol compared to the total PM2.5 mass. Plot a) shows results from a daily 24h average and b), 1h average. In plot b), four specific events in which the peak in PM2.5 is driven by sulfate (solid arrow, 1s – 4s) and by EC/OC (dotted arrow 1c –4c) are shown in the graph. Table 1 summaries pertinent measurements at these times. Note that in some cases, the EC/OC events are also associated with sulfate, examples are labeled with letters A-D.

14 Table 2: Time, Total Aerosol Fine Mass, And Concentration Of Aerosol Species During Episodes Identified In Figure 2. # TC/PM is the total carbon (OC x 1.4 + EC) divided by fine aerosol mass (PM2.5) * Since the sulfate peaked 1 hour prior to the PM2.5 in this case, the average over 2 hours is given here. At 16:30 the sulfate peak was 41.2 µg m -3 and the PM2.5 49.8 µg m -3, in the following hour, 17:30, the sulfate was 34.2 µg m -3 and PM2.5 70.7 µg m -3.

15 Health Study with Human Subjects The pollutants monitored will be: 1) PM 2.5- 24 hour integrated sample, pump and filter 2) Ozone- Ogawa Type Badge, Analysis by Ion Chromatography 3) SO2- Ogawa Type Badge, Analysis by Ion Chromatography 4) NO2- Ogawa Type Badge, Analysis by Ion Chromatography 5) EC/OC- 24 Integrated Samples. Analyzed by reflectance and thermal distillation

16 Conclusions This is a reasonable method to obtain new information regarding pollutants and health effects. The concentrations of pollutants vary greatly during the day. Real time monitoring will provide valuable information regarding the effects of pollution on individual health at various times of the day, and Study will provide valuable information on how to decrease the risk of health injury due to pollutants for all people, in all areas of the city.


Download ppt "A Project to Characterize The Effects of Transient Air Pollutants on the Health of African-Americans in Atlanta, Georgia John H. Hall Morehouse College."

Similar presentations


Ads by Google