1 Xccelerated Coagulation For wastewater Treatment and Reuse in Textile Processing House

2 Water & Wastewater treatment technology focused venture. Engaged in: Research and Development of Electrochemical process based water and wastewater solutions. Development of Low cost wastewater treatment & reuse solution for local industries. Development of Chemical free disinfection, sanitation and cleaning process for industries, hospitals, hotels and domestic applications. Sector focus: Chemical, Pharmaceutical, Food processing, Textile, Metal processing and Dairy Medical and Hospitality industry About KAASHPRA GLOBAL ENVIRO CARE

3 Problem with Textile Processing Wastewater treatment System High volume of wastewater Very Scarce space available for in- plant treatment Complex nature of wastewater with dyes and auxiliaries Biological treatment unable to handle organic and hydraulic loads Larger treatment plant based on biological system are not viable – from engineering and economic point Manpower is not readily available to handle conventional plants

4 About Xccelerated Coagulation

5 Xccelerated Coagulation treatment of Textile Wastewater - Tomorrow’s Technology Today 1.Conventional process includes 4 to 5 treatment steps: Primary, Filtration, Secondary, Clarification, Tertiary 2.Generates sludge at multiple points 3.Cannot be made automatic Conventional ProcessElectrochemical Process 1.Single stage operation, two stages at maximum 2.Generates sludge at single point 3.Sludge volume is substantially low 4.No additional chemicals 5.Completely automatic

6 Case Studies

7 Treatment of wastewater from Textile Processing house (Right – Before treatment, Left – After treatment), Initial COD: 800 ppm, Treated COD: <100 ppm

8 Treatment of wastewater from Textile Processing house (Right – Before treatment, Left – After treatment), complete removal of Turbidity

9 Treatment of wastewater from Textile Processing house Raw COD: 1908 Treated COD: 119 Appearance: Completely clear water

10 Raw COD: 2544 Treated COD: 100 Appearance: Completely clear water Treatment of wastewater from Textile Processing house

11 Raw COD: 2063 Treated COD: 636 Appearance: Very light tint yellow color

12 Results from on Field Trial in Textile Processing house After Before After Trials conducted at Textile processing house at Various treatment flow rates: Sample NameDetailsCOD 1RAW1200 240000 - 50000 L/day400 360000 – 70000 L/day250 490000 – 100000 L/day190 Sample NameDetailsCOD 1RAW2000 230000 – 40000 L/day400 340000 – 50000 L/day340 480000 – 90000 L/day200 Day 1 Day 2 Day 3 Sample NameDetailsCOD 1RAW400 2100000 – 110000 L/day <150

13 Economics of Treatment

14 Economics of Xccelerated Coagulation Treatment Electrochemical System for 100 KL/day Textile house needs: 1.3 to 4 sq m of Area (excluding Filtration area) 2.8 to 10 HP of total power source 3.Treatment cost varies between 8 to 12 Rs./1000 liter* 4.Capital cost in range of 10-12 Rs./Liter** Unique advantages of Treatment process 1.Lower Sludge Volume 2.70-80% reduction in chemical use 3.Reusable water in high volume application like washing, rinsing etc. 4.Fully automatic 5.Negligible maintenance 6.Ease of capacity expansion * - Approximate treatment cost ** - Filtration system under client scope