1
December, 2010 Vmax – Indoor vacuum circuit-breakers for Primary Distribution Product presentation 1VCP – Rev. D, en – Presentation – © ABB Group April 16, 2017 | Slide 1
2
Available versions acc. to IEC STDs
Vmax Available versions acc. to IEC STDs Compliance to IEC 12 kV … 17.5 kV ; 630 … 1250 A ; 16 … 31.5 kA Fixed for freestanding installation Withdrawable for ABB UniGear ZS1 switchgear (width 550 mm) Withdrawable for ABB PowerCube module (width 600 mm) Fixed for ABB UniGear 500R switchgear (width 500 mm) © ABB Group April 16, 2017 | Slide 2 2
3
Available versions acc. to ANSI STDs
Vmax Available versions acc. to ANSI STDs Compliance to C37.54 – C37.09 – C37.04 – C37.55 UL listed type L (sticker on request) 15 kV ; 1200 A ; 25 … 31.5 kA (3 cycles) Fixed for freestanding installation Withdrawable for ABB PowerCube module (width 600 mm) © ABB Group April 16, 2017 | Slide 3 3
4
Vmax ANSI version versus IEC version:
Shunt tripping releases suitable for “3 cycles” interruption Wiring with UL certified cables (& AWG cross-section) Nameplate with ANSI parameters Mechanical indicators according to ANSI STDs (symbol & colour) Specific Manual Booklet
5
Vmax Overview Open/close aux. contacts (standard set of ten aux.c.)
Additional opening release Locking magnet in the actuator Opening pushbutton Closing pushbutton Shunt tripping release Built-in lever for closing spring manual charging Undervoltage release (missing in the picture) Shunt closing release Signalling device for closing springs charged/discharged Mechanical operation counter Geared motor for closing spring charging
6
Vmax Overview
7
Vmax Fields of application
Power distribution Cable control and protection Overhead control and protection Transformation and distribution substations Motor and transformer control and protection Generator control and protection Capacitor bank control and protection
8
Vmax Strenghts Application where space saving is a premium
Compact dimensions compared to existing VD4 Freestanding vacuum interrupters Moulded case design
9
Vmax Features Vacuum interruption technique
Contacts in vacuum protected against oxidation and contamination Sealed for life vacuum interrupters Vacuum interrupters and EL mechanical actuator already used and tested in new VD4 series Limited switching energy 10,000 mechanical operations Stored energy operating mechanism with built-in anti-pumping device and closing spring charging lever Insulating monobloc Operating mechanism and monobloc fixed to a sturdy metal frame Easy customization with a complete range of accessories Locks to prevent incorrect and hazardous operations
10
Vmax Standard equipment
Mechanical signalling device for CB open/closed Mechanical signalling device for closing spring charged/discharged Opening and closing pushbuttons Mechanical operation counter Built-in lever for manually charging of closing spring Anti-pumping mechanical built-in function 5 + 5 auxiliary contacts Connection terminals and terminal board for auxiliary circuits (for fixed CB) Isolating contacts, cord with connector (plug only), racking-in/out lever (for withdrawable CB)
11
Vmax Other accessories, on request
Shunt tripping release Additional shunt tripping release Shunt closing release Opening solenoid (for self-supplied overcurrent relay ABB PR family) Undervoltage release Electronic time delay (which must be mounted externally in relation to the circuit breaker) for undervoltage release Mechanical override for undervoltage release Opening and closing pushbuttons protection Opening and closing pushbuttons padlock Key-lock in open position 5 extra auxiliary contacts
12
Vmax Other accessories, on request
Motorgear for closing spring charging Signalling contact closing spring charged or signalling contact closing spring discharged Locking magnet in the truck to prevent racking-in with auxiliary circuits disconnected (for withdrawable CB only) Transmitted contacts in the truck for signalling inserted or isolated circuit breaker (for withdrawable CB only) Interlock for fixed circuit breaker which is converted in withdrawable ones by the customer (to prevent racking-out/in with the circuit breaker closed and to prevent closing operation during the translation)
13
Vmax Compared to VD4, Vmax cannot be fitted with:
Transient contact with momentary closing during circuit breaker opening Motorized truck
14
© ABB Group April 16, 2017 | Slide 14 14