1 AT&T Inspection Products
FBP-ATT-1 FBP-ATT-2 FBPT-ATT-TK1 Operations Guide Version 3.0 May 04, 2007

2 Agenda Fiber Basics Equipment Overview Fiber Inspection Fiber Grading
Maintenance Kits Note: For additional information about Westover equipment as it pertains to AT&T processes & procedures please reference the following Apex document: ATT-TELCO “Construction FWG LFO-In SSIM I&R Outside Plant:  Fiber Optic Connector & Adapter Inspection and Cleaning Tools & Procedures”

3 Fiber Basics: Connectors
Body Ferrule Fiber Body The connector body holds the ferrule and holds the fiber in place Ferrule Thin cylinder where the fiber is mounted; acts as the fiber alignment mechanism; the end of the fiber is located at the end of the ferrule Fiber Cladding Optical fiber layer (lower refractive index) that has direct contact with the Core layer. Typically 125μ in diameter. Core The critical center layer of the fiber (total internal reflection) where light passes through. Typically 9μ for singlemode fiber. LC Connector Core Singlemode (9μ) Cladding (125μ) Microscope /Display View

4 Why Inspect? Dirt & Contamination
Contamination is the number one cause of troubleshooting in optical networks Contaminated connectors that are mated cause embedded debris and pits, which are permanent forms of damage Contamination must be removed prior to mating connectors Clean Dirt Pit

5 Inspect before you connect!
Note: For specific information regarding the AT&T cleaning procedures, please reference ATT-TELCO

6 Inspect Both Sides Two Types of Inspection Patch Cord Inspection
The HD2 Display has a microscope for patch cord inspection built into the device. Bulkhead Inspection Attaching the Probe microscope to the display enables inspection of fiber end-faces within a bulkhead.

7 Where Inspection Occurs
Inspection of fiber end-faces is critical at EVERY STAGE of handling fiber! Component Mfg. System Test Installation Troubleshooting & Maintenance System Assembly Receiving & QC Network Test

8 Equipment Overview Westover Fiber Inspection Microscopes are used for visual end-face inspection of fiber optic connectivity. Integrated Visual Fault Locator (VFL) Change adapters to match connector being inspected Built-in Patch Cord Microscope 3.5” LCD Video display Dual (200X & 400X) mag. Probe inspects through bulkheads Built-In coaxial illumination (100,000 hour life) Ergonomic design easily fits in hand Change tips to match connector being inspected

9 HD2 Display Overview The HD2 Display is a compact and ergonomic multi-functional display with a 3.5” TFT LCD screen with a rugged design suitable for use indoors and outdoors. Features Ruggedized, drop tested enclosure 3.5” TFT LCD display P5 Probe input Patch cord viewer Visual Fault Locator (VFL) Removable battery pack (8 “AA” batteries) Power saving Grip Switch Low battery warning LED AC adapter (power supply 110V/12VDC). Brightness control Socket for ¼-20 UNC Tripod mount

10 HD2 Display Battery Installation Power & Charging the Batteries 1 2 3
Note: The NiMH rechargeable batteries will not and cannot be recharged inside the HD2 Display. They must be removed from the tray and charged with the included battery charger. Insert 8 fully charged “AA” batteries into the battery pack Align the ‘positive’ and ‘negative’ ends (contacts) on the bottom of the battery tray to their respective ends inside the HD2 Display and insert the tray into the compartment on the top left-hand side of the display Attach the cover to securely lock and conceal the battery pack Power & Charging the Batteries The HD2 display can also be powered by attaching the 110V/12VDC Power Supply Once the batteries are too low in power, the screen will turn off and the Low Bat indicator will illuminate.

11 HD2 Display: Power Switch
Power-On Mode Switch the power setting to the On mode The green LED indicator will illuminate next to “Power” at the bottom of the display Front View Side View

12 HD2 Display: Power Switch
Grip Switch Mode: This setting is used to maximize battery life Switching to “Grip” Mode activates a pressure-sensitive Grip Switch at the back of the unit. In the Grip mode power can be turned On or Off as pressure is applied and released Grip Switch 1 2

13 HD2 Display Brightness Control, Tripod Socket, Table Stand & Hanger
4. Hanging Accessory Brightness Control: Adjusts the brightness of the display screen with the aperture wheel Tripod Socket: Allows the display to be mounted on tripod stands for hands-free operation Table Stand: Position the display on flat surfaces for hands-free operation Hanging Accessory: Hand the display where suitable for hands-free operation

14 Patch Cord Module (integrated microscope)
To use the integrated microscope (patch cord-view)… Select the appropriate patch cord adapter from the three listed on the next page and install onto the patch cord module Insert/attach the patch cord into the adapter on the patch cord module input Use the Power Selector to select either “On” or “Grip” Verify that the internal patch cord microscope is selected (the A/B LED which is controlled by pushing the “A/B” button should be illuminated) Use the Focus wheel to adjust the focus on the fiber end image If the FMAE-MTPA MPO is used: Steps 1 & 2 Step 4 Step 5 Small Panning Knob FMAE-MTPA MPO The “Large” Panning Knob on the MPO adapter should be facing front, aligned vertically with the “A/B” button and set in a fixed position Use the “Small” Panning Knob to adjust/center the fibers vertically on the display Use the “Large” Panning Knob to pan across the connector to view the fibers individually Large Panning Knob

15 Patch Cord Module Adapters
Overview The various adapters are interchangeable on the Patch Cord module of the HD2 Display, allowing inspection of different types of fiber optic connectors. FMAE-U Universal 2.5mm adapter FMAE-U Universal 1.25mm adapter FMAE-MTPA MPO (angled) adapter

16 P5 Probe Microscope Overview
The P5 Probe Microscope incorporates an imaging system, integrated light source, video camera, focus mechanism, magnification control and connector-specific tips. The P5 Probe Microscope can be used to inspect both sides of an optical interconnect. Focus Wheel used to adjust focus on the display screen Dust Cap remove before attaching probe tips 4-pin Connector ensures a secure and firm latch-lock connection with the HD2 display Magnification Control used to adjust between “low” and “high” magnification settings

17 P5 Probe Microscope Connecting the Probe and Display 1 2 3
Locate the “female” connection on the right-hand side of the display unit Align the notch-key configuration of the “male” end of the probe microscope to the “female” end of the display unit and attach Secure by tightening the screw

18 Inspection Tip Configuration
Bulkhead Tips: Long Reach Bulkhead Tips: 60° Angled Patchcord Tips Barrel Assembly Bulkhead Tips: Standard Bulkhead Tips: Ribbon Connectors

19 Bulkhead Inspection Tips
Simplex Inspection Tips Bulkhead tips can inspect simplex connectors located behind a bulkhead 60° angled tip can inspect connectors located in tight, hard-to-reach areas SC Bulkhead Tip Angled 60○ FBPT-SC-A6 SC Bulkhead Tip FBPT-SC Barrel Assembly FBPP-BAP1 Simplex Fiber View

20 Bulkhead Inspection Tips MTP APC Bulkhead Inspection Tip
RibbonDrive™ Inspection Tips Provide stable and repeatable inspection of all fibers on the ribbon ferrule endface Provide inspection of high density, multi fiber array connectors mounted within a bulkhead adapter. Panning knob allows the user to view each fiber in a liner array. MTP APC Bulkhead Inspection Tip Extra Long Reach FBPT-MTPA-XL Ribbon Fiber View

21 Bulkhead Adapters Overview
Within each kit are 3 bulkhead adapters to compliment the 3 probe tips (LC, SC, MPO). These adapters can be used in conjunction with the probe tips to inspect patch cords at both low and high magnification settings. LC Patch Cord Inspection SC MPO

22 Visual Fault Locator (VFL)
Overview The integrated Visual Fault Locator (VFL) module employs a powerful red laser designed to couple to optical connectors, giving you the ability to locate damaged or broken optical fibers. Step 3 Step 1 Step 4 Insert the connector (SC Connector shown) into the VFL input located on the top of the display Press the On/Off button to activate the VFL The red LED indicator (next to Power) will illuminate when the VFL is active Press the Flash button to activate the flashing-mode Step 2 Illumination indicating damage or break Note: The VFL is equipped with a 2.5mm interface. Converters for other ferrule types such as 1.25mm are available from Westover Scientific. Another method for interface conversion includes using a hybrid patch cord and adapter.

23 Fiber Inspection Procedures
Simplex Patch Cords Switch/toggle the “A/B” button to turn the patch cord module ON (red indicator). Remove the dust cap from the patch cord and place in an anti-static (ESD-sensitive) bag (save/secure the dust cap for later use). Insert the patch cord into the patch cord module and focus the image to inspect. Focus Image w/ Focus Wheel Note: It is essential to implement Electrostatic Discharge (ESD) preventive measures (such as using anti-static bags and wristbands) when working with ESD-sensitive equipment.

24 Inspection Procedures
Bulkhead Adapters (Simplex Connectors) INSPECT (SC & LC) Select the appropriate probe tip and patch cord adapter that match the connector and attach them to the system. Remove the dust cap from the bulkhead adapter and place in an anti-static (ESD-sensitive) bag (save/secure the dust cap for later use). Inspect the connector within the bulkhead. Note: It is essential to implement Electrostatic Discharge (ESD) preventive measures (such as using anti-static bags and wristbands) when working with ESD-sensitive equipment.

25 Inspection Procedures
Ribbon Patch Cords Switch/toggle the “A/B” button to turn the patch cord module ON (red indicator). Attach the MPO APC Patch Cord Adapter to the patch cord module Remove the dust cap from the patch cord and place in an anti-static (ESD-sensitive) bag (save/secure the dust cap for later use). Insert the patch cord into the patch cord module and focus the image to inspect. Use the “Small” and “Large” Panning Knobs on the MPO adapter to adjust the display image vertically and to pan horizontally across the fiber ribbon array, respectively. MPO APC Adapter Panning Knobs Note: It is essential to implement Electrostatic Discharge (ESD) preventive measures (such as using anti-static bags and wristbands) when working with ESD-sensitive equipment.

26 Inspection Procedures
Bulkhead Inspection (Ribbon Connectors) Select the MPO bulkhead tip and attach to the probe. Remove the dust cap from the bulkhead adapter and place in an anti-static (ESD-sensitive) bag (save/secure the dust cap for later use). Inspect the MPO connector behind the bulkhead. Use the Panning Knob on the MPO probe tip to view each fiber across the ribbon array. Panning Knob Note: It is essential to implement Electrostatic Discharge (ESD) preventive measures (such as using anti-static bags and wristbands) when working with ESD-sensitive equipment.

27 Cleaning Tools CLEANER FIBER OPTIC MPO (PID 310095690)
Note: AT&T has recently updated cleaning procedures by transition away from using swabs for bulkhead cleaning. The new procedures involve use of the tools shown below. Further details on these procedures can be found in ATT-TELCO CLEANER FIBER OPTIC MPO (PID ) Used for cleaning the ferrule end faces of MPO connectors. This device cleans all 12 fibers at once. Capable of cleaning ferrules with or without guide pins. Cleaning count: 500 FERRULE MATE SFM-250 (PID ) Used for cleaning the ferrule end faces of 2.5mm simplex fiber connectors (ex: SC, ST, FC). Cleaning count: 350 FERRULE MATE SFM-125 (PID ) Used for cleaning the ferrule end faces of 1.25mm simplex fiber connectors (ex: LC). Cleaning count: 350

28 Inspect before you connect!
Note: For specific information regarding the AT&T cleaning procedures, please reference ATT-TELCO

29 Grading Fiber: Pass Fail Criteria
Dirt & Defects Pass/Fail criteria for AT&T can be found in the following section of ATT-TELCO : The Universal Grading Template is only used when there is a defect that can not be removed in the cleaning process described in ATT-TELCO

30 Grading Fiber: Pass Fail Criteria
Dirt & Defects Identify the debris and defects which can not be removed To grade these defects, place the template over the fiber on the “low” side Use the “Keys to Zone” section of the template to determine in which zone the identified defects are located Use the reference dots on the template to identify the size of the defects Refer to the appropriate table for Pass/Fail Criteria in ATT-TELCO

31 Grading Fiber: Pass / Fail Criteria
The following Pass/Fail criteria can be found in ATT-TELCO Suggestion: Keep this criteria readily available when inspecting (print and keep in kit with grading guide).

32 Maintenance Contamination
In general, this kit requires little or no maintenance. However, there are issues that can arise and it’s important to know how to recognize when the unit needs service. If the optical system becomes contaminated, it can degrade the image quality. There are 3 symptoms of this condition: Camera Sensor Contamination Lens Contamination Tip Contamination Note: All service work is performed at Westover Scientific’s factory just outside Seattle, Washington.

33 Camera Sensor Contamination
This sort of contamination will show as a black spot. These spots look like dirt on the fiber and it can be difficult to determine if the dirt you see is on the fiber or on the camera. There is a simple way to discern the difference. If you suspect the camera may have been contaminated: Insert a fiber, focus and rotate the probe or the fiber… If the black spot stays in one place on the display while the image moves, then there is dirt on the camera and it is in need of service If the black spot moves around the display with the fiber image, then it is on the fiber Black Spot (Dirt) Camera Sensor Contamination Note: All service work is performed at Westover Scientific’s factory just outside Seattle, Washington.

34 Lens Contamination If there is a lens contamination, it creates a brown or gray shadow on the display image. Most users will never notice this, but if you do and would like to fix it, ship it back to the factory for cleaning. This type of contamination does not impact the scope’s ability to perform well, as you can still see and discern all details of the fiber. Shadow Lens Contamination Note: All service work is performed at Westover Scientific’s factory just outside Seattle, Washington.

35 Tip Contamination The tips in this kit all have self-contained, recessed imaging lenses within them. As such, they can become contaminated through regular use. Contamination of these lenses will not affect the image until they are heavily covered. If this occurs, the image will become uniformly cloudy. You will see a haze across the entire image Tip Contamination Note: All service work is performed at Westover Scientific’s factory just outside Seattle, Washington.

36 Maintenance The probe and display are ruggedized and should fair very well over their life in the field. Nevertheless, they are electro-optical devices and should be handled with care whenever possible. The tips are somewhat more sensitive and should be protected as best possible. All of the tips should be stored in the provided plastic bags and hard case when not being used.

37 Kits: FBP-ATT-1 (PID 310108329) * Note: Kit does not include FBPP-BAP1
Hard-sided case Display-HD2 w/ Patchcord Scope (200X) & Visual Fault Locator Probe, 200/400X, 4-pin connector Tip: SC Bulkhead, Angled 60○ Tip: Univ. 1.25mm, Angled 60○ Tip: MTP-APC Bulkhead, extra long reach LC Bulkhead adapter SC Bulkhead adapter MTP Bulkhead adapter Adapter: MTP-APC, for E series Adapter: Universal, 2.5mm Adapter: Universal, 1.25mm 2 battery trays 12 “AA” NiMH batteries 15-min battery charger w/ 4 “AA” NiMH Power supply, 110V/12VDC Pouch, for HD2 Display Operations Manual * Note: Kit does not include FBPP-BAP1

38 Kits: FBP-ATT-2 (PID 310124102) Hard-sided case
Display-HD2 w/ Patchcord Scope (200X) & Visual Fault Locator Probe, 200/400X, 4-pin connector w/ FBPP-BAP1 Barrel Assembly Tip: SC Bulkhead Tip: LC Bulkhead, Long Reach LC Bulkhead adapter SC Bulkhead adapter Adapter: Universal, 2.5mm Adapter: Universal, 1.25mm 2 battery trays 12 “AA” NiMH batteries 15-min battery charger w/ 4 “AA” NiMH Power supply, 110V/12VDC Pouch, for HD2 Display Operations Manual

39 Kits: FBPT-ATT-TK1 (PID 310124110)
Tip: SC Bulkhead, Angled 60○ Tip: Univ. 1.25mm, Angled 60○ Tip: MTP-APC Bulkhead, extra long reach Adapter, MPO/MTP Bulkhead Adapter, SC Bulkhead Adapter, LC Bulkhead

40 Individual Items Part Number PID # Description FBP-P5 310124136
Dual Magnification Probe Microscope (200x & 400x) FBP-HD2-P2-V 3.5" HD2 Display with Integrated Patch Cord Scope and Visual Fault Locator (includes FMAE-U25) FBPT-MTPA-XL Tip, MTP/MPO APC Bulkhead, Extra Long Reach FBPT-SC-A6 Tip, SC Bulkhead, Angled 60 Degrees FBPT-U12-A6 Tip, Universal 1.25mm Bulkhead, Angled 60 Degrees FBPT-SC-APC Tip, SC-APC Bulkhead FBPT-LC-APC Tip, LC-APC Bulkhead FBPT-U25M Tip, Universal 2.5mm Patch-cord FBPT-U25MA Tip, Universal 2.5mm APC Patch-cord FBPT-U12M Tip, Universal 1.25mm Patch-cord FBPT-U12MA-SF Tip, Universal 1.25mm APC Patch-cord FMAE-U25 Adapter, Universal 2.5mm Patch-cord FMAE-U12 Adapter, Universal 1.25mm Patch-cord FMAE-MTPA Adapter, MTP/MPO APC Patch-cord FBPP-BK1 Battery Kit, Extra Battery Tray, Charger and 12 Rechargeable Batteries FBPT-ST Tip, ST Bulkhead FBPT-ST-A6 Tip, ST Bulkhead, Angled 60 Degrees FBPT-LC Tip, LC Bulkhead FBPT-LC-L Tip, LC Bulkhead, Long Reach FBPT-SC Tip, SC Bulkhead FBPP-HSC11 Large Hard Case FBPP-MK1 Mating Adapters - MTP, SC, LC (1 ea.)