Optimizing heater power in a thermal process. Problem Statement Laminar Inflow at 20°C Outlet Heater 1 Heater 2 Maximize the temperature at the outlet.

Similar presentations


Presentation on theme: "Optimizing heater power in a thermal process. Problem Statement Laminar Inflow at 20°C Outlet Heater 1 Heater 2 Maximize the temperature at the outlet."— Presentation transcript:

1 Optimizing heater power in a thermal process

2 Problem Statement Laminar Inflow at 20°C Outlet Heater 1 Heater 2 Maximize the temperature at the outlet By changing the power at the two heaters Constrain the peak temperature at the heaters Gravity Air flow through a channel Two heaters raise the air temperature The buoyancy force accelerates the flow Optimization Problem: Air

3 Step 1: Set up a Non-Isothermal Flow model Define the flow conditions at the inlet Fix the inlet temperature Open boundary at the outlet Two different heater flux conditions for the two heaters Buoyancy force

4 Step 2: Solve the problem and examine results Since we use the Open Boundary, the Non- Isothermal Flow interface automatically sets up a post-processing variable for us: comp1.nitf.open1.Tave This variable takes the mass-flow-weighted temperature average at the open boundary and accounts for the non-uniform velocity and any change in density over the outlet. This weighted outlet temperature is ~61°C and is what we want to improve

5 Step 3: Add Optimization to the Study Default Optimization Solver Settings

6 Step 4: Define the Objective Maximize the mass-flow-weighted average temperature at the outlet

7 Step 5: Define the Control Variables Choose reasonable initial values, and apply boundary to the variables. A lower bound of 0 is physically reasonable. An upper bound is not necessary for this case.

8 Step 6: Define the Constraints Keep the maximum temperature at the heaters below 95°C

9 Solve & Evaluate Results Peak temperature at heaters in 95°C Temperature at outlet is 70°C Heater 1: 7.9 W Heater 2: 4.0 W


Download ppt "Optimizing heater power in a thermal process. Problem Statement Laminar Inflow at 20°C Outlet Heater 1 Heater 2 Maximize the temperature at the outlet."