93PM: Value, Benefits, and Features

Similar presentations


Presentation on theme: "93PM: Value, Benefits, and Features"— Presentation transcript:

1 93PM: Value, Benefits, and Features
Where aesthetics meet intelligence “house of brands” – companies with many unrelated consumer products usually build a house of product brands. Take P&G. Each brand has unique attributes and customers. Tide has one reputation, Pringles or Durcell another. One brand’s reputation doesn’t rub off on the others’. A “branded house” is one master brand, with core attributes and benefits that customers value across all it products and services. Take Sony. Sony always means advanced styling and features, superior quality and performance, total satisfaction, great value. One master brand. Many products, one great reputation What about Eaton? Eaton has moved from a “house of brands” to a “branded house”. Now we are one company, one business, one reputation, that all our customers and markets value. Why? Two reasons: Eaton customers want and value the same things: products that reliable meet their crucial high-performance needs and add higher value to their business bottom line. Any Eaton product and service delivers that critical performance and higher value, even Golf Pride golf grips

2 Eaton 93PM 100 kW UPS Overview The perfect three-phase white or gray space solution for today’s datacenter Industry leading: Efficiency (97%-99%) Footprint (35% < closest competitor, standard rack size) Flexibility (thermal management options, service from front) Manageability (touchscreen, modular design, remote man.) Communication Cards 50 kW Power Module Product Snapshot Power Rating: 60, 70, 80, 90, 100 kW Power Factor: Unity PF 1.0 Topology: Double-Conversion with ESS Mode Efficiency: 97% - 99% Input / Output Voltage: 480V Input THD: < 3% Configuration: Tower Options: line and match EBC, IAC-D, MBS… 50 kW Power Module Static Switch I/O connections 93PM is the next gen (400/480V) with exciting new features for 2013

3 93PM value proposition The Eaton 93PM UPS combines unprecedented efficiency, reliability and vertical or horizontal scalability with eye-catching design. A space-saving, flexible device that’s as easy to deploy as it is to manage, it’s the perfect three-phase white or grey space solution for today’s data center.

4 Top 93PM benefits Lowest TCO
Reduces power and cooling OPEX through industry-leading energy efficiency Lowers CAPEX through internal modular scalability and internal redundancy Conserves valuable data center floor space with its compact footprint Ease of deployment Maximizes deployment flexibility by providing innovative thermal management options, flexible configurability and full service access from the front Simplifies installation by fitting perfectly in line or alongside any standard-depth rack Ease of management Provides easier access to detailed status information through its large, user-friendly LCD touchscreen interface Optimizes server virtualization solutions through its full suite of power management and connectivity software Increases uptime through its 24x7 remote monitoring and reporting capabilities

5 Top 93PM benefits Lowest TCO Ease of deployment Ease of management
Up to 99.1% efficient in ESS mode. Up to 97% efficient in double conversion mode. (Provides the highest energy cost savings across the entire operating load range) Internal modular scalability allows the customer to pay as they grow (available at full launch) Internal redundancy reduces the need for additional UPS’s (available at full launch) Space-saving designed UPS and ‘line and match’ accessory suite Ease of deployment Space-saving, standard rack depth form factor Multiple thermal management options Flexible configuration and pass-through wiring can be placed at either end of a row or against the wall Flexible run time options Top or bottom cable entry Ease of management Intuitive, touch-based color LCD interface Green/yellow/red LED light-bars that make system status visible from a distance Complete front serviceability Full suite of connectivity and software management solutions 24/7 E-notify remote monitoring

6 Lowest TCO: Energy efficient
Reduces power and cooling OPEX through industry-leading energy efficiency Up to 99.1% efficient in ESS mode. Up to 97% efficient in double conversion The 93PM provides the highest efficiency across the entire operating load range!

7 ESS: How is it different than “Eco” mode
Fastest Transfer Times: ESS offers < 2ms transition times for an outage condition (vs. up to 12ms for Eco Mode). Inherent Surge Protection: Transformer-less ESS topology offers non-degenerative filtering for lightning strikes. Load Fault Detection and Clearing: ESS determines if the fault is at the source or load. For load faults, the UPS will maximize it’s fault clearing current by not only turning the inverter on but also leaving the source engaged with the critical load (providing the maximum fault clearing current).

8 93PM energy savings Summary:
ESS provides the ultimate in energy savings (ideal for data center environments and more)! For those applications requiring double conversion, the 93PM provides the highest energy cost savings as well! Both modes of operation provide the highest energy cost savings across the entire operating load range.

9 co-lo’s, fast growing .com’s and businesses!
Lowest TCO: Scalable and redundant (available with full 200kW launch in Q3) Grow Vertical Ideal for co-lo’s, fast growing .com’s and businesses! Lowers CAPEX through internal modular scalability and internal redundancy in future versions: Scales up in modular 50 kW increments, so there’s no need to buy excess capacity in advance Delivers long-term value because it grows as your business does Features built-in modular redundancy, hence there’s no need for a second unit to keep uptime high

10 $700 annual footprint savings (*using $150 sq-ft annual cost)
Lowest TCO: Footprint $700 annual footprint savings (*using $150 sq-ft annual cost) Conserves data center floor space Save up to $700 annually in footprint savings (against leading competitor “L”). Slim line accessories (slim detachable MBS provides a “true” low cost solution). Full launch space savings benefits: Built-in redundancy/scalability reduces needs for redundant UPS’s (saving cost and space). Internal batteries up to 50kW provides the ultimate footprint solution. Fits through standard doors and in elevators, so no need for cranes or dismantling

11 Ease of deployment: Configurability
Maximizes deployment flexibility by providing flexible configurability Standard-depth form factor Fits in-line or alongside any standard server rack Fits against the wall, too Top or bottom cable entry Supports both raised floors and overhead power distribution Mix-and-match accessories Deploys in multiple configurations on either side of UPS without affecting pass-through wiring Supports end-of-row applications (ideal for mirrored A/B end of row applications) Sleek design looks great in either white or grey space

12 Ease of deployment: Flexible thermal management
Optional front to rear air flow is ideal for hot/cold aisle configurations. Slim chimney 93PM connections allows for overhead busway and cable trays. Maximizes deployment flexibility by providing innovative thermal management options.

13 Ease of management: LED status bars
The green/yellow/red LED light-bars make system status visible from a distance in data centers. Green LED’s -> System online and normal. Yellow LED’s -> System on battery or bypass. Red LED’s -> Service required.

14 Ease of management: LCD touchscreen display
A color touchscreen display that will make your kids proud!

15 Ease of management: Connectivity options
Power Xpert Gateway Mini-slot card: Designed specifically to connect the Eaton 93PM UPS to Ethernet networks Embedded web server 1G flash memory and 128 MB RAM Multiple log files stored directly in the card’s memory Multi-module  support Multiple protocol support including SNMP, BACnet IP, Modbus TCP, Modbus RTU Note – up to two cards can be used for independent/redundant networks. Industrial Relay Mini-slot card: 5 relays Connections: 250 V 3 – 5 A Isolated Terminal block connection

16 Ease of management: Comprehensive software suite
Eaton’s intelligent power manager software enables you to: Remotely monitor and manage multiple devices across your network from a single interface; this can be integrated into an already existing platform, such as VMware, Microsoft or Citrix Measure power consumption and kWh to calculate power usage effectiveness Trigger load shedding of lesser priority server workloads to extend battery run time in a virtualized environment. Trigger workload transfer to disaster recovery site with no loss of data, using VMware’s Site Recovery Manager. Eaton’s intelligent power protector software enables you to: Reboot hung-up machines through watchdog functionality Avoid data loss by automating graceful shutdown of machines during extended power outage Maximize uptime with redundancy capabilities for dual-cord servers

17 Eaton 93PM 100 kW Taking a closer look–the UPS functional core
* Top cable entry requires sidecar option.

18 Eaton 93PM UPS 100 kW accessories
Empty or MBS side car required for top cable entry. Interconnect cables included Side car required for remote top cable entry. Line and match interconnect cables included 93PM Battery Runtime Chart (E50) - Minutes Load kW 1 IBC-L 2 IBC-L 3IBC-L 4 IBC-L 20 129.2 289.4 463.9 30 80.8 181.1 290.2 405.5 40 58.2 130.2 208.7 291.7 50 45.1 101.0 161.9 226.3 60 36.7 82.1 131.6 183.9 70 30.7 68.8 110.3 154.1 80 23.1 58.9 94.5 132.0 90 19.9 51.4 82.4 115.1 100 17.2 45.5 72.9 101.8 Interconnect cables are not provided. E39 available providing 11min at 100kW

19 Eaton 93PM UPS 100 kW: Technical specification
100% Real Power (1.0 PF) Lowers customers THD with <3% iTHD (market lead) 0.8 leading to 0.8 lagging without de-rating

20 93PM: Unlock real power Why Unity:
Modern data centers loads are approaching unity power factor. “Since the data center power factor is high and, as such, kW is very close to kVA, some people discount the difference and use the two interchangeably. This is very dangerous and can lead to the creation of “phantom” capacity. “ – datacenterguru.blogspot.com The 93PM addresses this by providing 100% real power.

21 93PM Summary Highest efficiency UPS in the market!
Why the 93PM will win! Highest efficiency UPS in the market! The most flexible installation and thermal management solutions Smallest footprint Unity power factor is ideal for today’s loads Lowest input current THD in the industry Future scalability and internal redundancy (with launch of 200kW offering) “Breakthrough innovations rarely occur within a technical discipline, or within a market, but almost always where you create a novel intersection.” - Clay Christensen …..the 93PM provides the combination of breakthrough innovations that will capture the attention of today’s markets!

22 Eaton 93PM UPS 100 kW accessories
MBS (Maintenance Bypass Slim ) Line and match and allows UPS removal IACD (Integrated Accessory Cabinet-Distribution) (with optional 42 pole panels and subfeed breakers). EBC (Line and match external battery cabinet) Wall mount maintenance bypass

23 Customer Drawings UPS and Battery Cabinet

24 Basic UPS Dimensions

25 UPS Sidecar mounts either side

26 UPS with sidecar-detail

27 Top/Bottom layout with Sidecar

28 Service Clearances and Environmental

29 Termination locations

30 One-Line

31 Screen shots

32 Meters Screen

33 Input Specs

34 Output Specs

35 Environmental specs

36 Voltage3 Configuration
UPS/Sidecar CTO UPS Family Product Line Model1 System2 Rating Voltage3 Configuration Internal Batteries4 Input Options5 Efficiency Options 1 2 3 4 5 6 7 8 9 P 93PM A 50 kW Capacity Frame 20 kW 400 V, 4 wire No Internal Batteries Single Feed, No ESS, no Internal MBS no VMMS B 50 kW Redundant Frame, 30 kW 400 V, 3 wire With Internal Batteries 1 UPM (3 strings), type 7Ah LL with Internal MBS with VMMS C 40 kW 480 V, 4 wire Dual Feed, With ESS, 2 UPM (3 strings), type 9Ah D 100 kW Capacity Frame, 50 kW 480 V, 3 wire (4 strings), type 7Ah LL E 60 kW 380 V, 4 wire (4 strings), type 9Ah F 100 kW Redundant Frame, 70 kW 380 V, 3 wire (5 strings), type 7Ah LL G 80 kW 360 V, 4 wire (5 strings), type 9Ah H 100 kW Redundant Frame 90 kW 360 V, 3 wire 3 UPM (6 strings), type 7Ah LL J 150 kW Capacity Frame 100 kW 415 V, 4 wire (6 strings), type 9Ah

37 Sidecar7 Breaker kAIC Rating Cabinet8 Configuration
UPS/Sidecar CTO Connectivity Slots Sidecar / Top Entry6 Sidecar7 Breaker kAIC Rating Cabinet8 Configuration Factory Location Generation Code 10 11 12 13 14 15 None (Empty) A No Sidecar no specification With Dress Skins, H HPO Generation 1 Top Air Exhaust 1 Network and EMP B No Breakers, Left Mount STD kAIC, all R RPO Breakers Aux Rear Air Exhaust 2 MODBUS and EMP C No Breakers, Right Mount STD kAIC, MBS No Dress Skins, BA1 Aux Only 3 Relay, Network and EMP D 2 Breaker, Left Mount High kAIC, all (MBS) 4 Relay E 3 Breaker, Left Mount High kAIC, MBS 5 PXGMS F 4 Breaker, Left Mount 6 Network G 2 Breaker, Right Mount 3 Breaker, Right Mount J 4 Breaker, Right Mount

38 Battery Cabinet IBC-L—432 VDC-36 batts

39 Remote / Top Entry Side Car
Battery Cabinet CTO System Version Accessory Associated UPS Model DC Voltage Battery Type Remote / Top Entry Side Car 1 2 3 4 5 6 7 8 9 10 P 93PM Z Accessories A EBC 50 KW 432V E PWR Line and Match, with no side car B SEBC 100 KW PWR Remote Installation, no side car C Seismic EBC 150 KW L Remote, with Left side car for top entry D 200 KW R Remote, with Right side car for top entry

40 Battery Cabinet Wiring

41 Battery Wiring Standalone vs Matching

42 IAC-D Cabinet

43 IAC-D CTO System Version Accessory Transformer KAIC Rating
Distribution Top Distribution Bottom 1 2 3 4 5 6 7 8 9 P 93PM Z Accessories D 50 KVA K1, Non TP1,480/208 Delta/WYE S STD KAIC No Distribution IAC-D E 100 KVA K13,Non TP1 480/208 Delta/WYE H High KAIC B 225A Panel Board Top 225A Panel Board Bottom F 150 KVA K1,TP1,480/208 Delta/WYE 1 Subfeed Breaker G 200 KVA K13,TP1 480/208 Delta/WYE 2 Subfeed Breaker 3 Subfeed Breaker 4 Subfeed Breaker C 400A Panel Board Bottom 5 Subfeed Breaker Distribution Breaker Type Branch Metering Cabinet Configuration Optional Breaker Open Generation Code 9 10 11 12 13 14 15 80% Rated Breaker None Standard Configuration No Optional Breaker Generation 1 w Top Exhaust 1 1 Optional 225A Breaker 80% Rated Breaker w Aux(Distribution Subfeed only) w Rear Exhaust 2 100% Rated Breaker(Distribution Subfeed Only) Seismic Configuration 3 100% Rated Breaker w Aux(Distribution Subfeed only)

44 Tomorrow’s battle card and roadmap session?
We will: Review the 93PM’s top three competitors PM launch roadmap (slim battery cabinet, full kW launch, additional features,…) 93PM price book review 9390 EOL plans What’s next after the 93PM launch?