R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Slide 1 GOSSAMER COVE Redwood City, CA Illustrated Preliminary Defect List Presented By: R.H. ADCOCK / ARCHITECT.

Similar presentations


Presentation on theme: "R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Slide 1 GOSSAMER COVE Redwood City, CA Illustrated Preliminary Defect List Presented By: R.H. ADCOCK / ARCHITECT."— Presentation transcript:

1 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Slide 1 GOSSAMER COVE Redwood City, CA Illustrated Preliminary Defect List Presented By: R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. 3550 Camino Del Rio North, Suite 305 San Diego, CA 92108 (619) 624-9272 FAX (619) 624-9566 www.rhadcock.com

2 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Overall

3 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Overall

4 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. 1.0 ROOFS Composition Shingle

5 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Degradation and tears in composition shingles.

6 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Leaks at complex intersections of roof.

7 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Shingle installed upside down.

8 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Metal flashing laps not sealed.

9 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Headwall flashing nailed through.

10 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Discontinuous edge metal at outside corners.

11 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Gaps in flashing.

12 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Cracked shadow board.

13 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Gutter system lifting shingles at eave.

14 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Penetration flashings not set in mastic.

15 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Penetration flashings not set in mastic.

16 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. 2.0 BALCONIES

17 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Balcony Overall

18 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Balcony waterproofing system failure; staining and water intrusion.

19 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Ponding at balcony/inadequate slope.

20 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. 5.0 EXTERIOR SIDING AND TRIM

21 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Exterior siding fasteners popping and overdriven.

22 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Exterior siding fasteners popping and overdriven.

23 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Missing sealant at joints in siding.

24 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Voids at penetrations.

25 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Water table flashing nailed through.

26 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Damaged siding installed.

27 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Exterior light fixture not sealed.

28 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Gaps and separation at wood trim.

29 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Gaps and separation at wood trim.

30 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Improper flashing termination at brick veneer; exposed building paper.

31 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Garage door wood trim in contact with concrete.

32 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. 8.0EXTERIOR DOORS

33 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. French door threshold failure; stained tack strip and missing sealant.

34 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. French door sticking/racked.

35 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Failed glazing strips at door exterior; leaking sealant.

36 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Improper door weather strip; gaps.

37 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. 9.0CONCRETE

38 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Concrete slab failure at garages/ponding and spalling.

39 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Concrete flatwork failure at driveway; cracking.

40 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Efflorescence at slab.

41 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Driveway with reverse slope to garage/ponding.

42 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Driveway slab with vertical displacement.

43 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. 11.0 WALLBOARD

44 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Drywall system failure; cracking.

45 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Drywall system failure; cracking.

46 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Wallboard cracks at doors.

47 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Window sill and jamb drywall cracking.

48 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. 14.0 SUB-FLOORS

49 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Floor sheathing is improperly fastened; floor squeaks.

50 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. 15.0MISCELLANEOUS ARCHITECTURAL

51 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Failure of rigid grout at counter tops to backsplash in kitchens; cracking.

52 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Kitchen ceramic tile failure; cracking.

53 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Laundry room ceramic tile failure; cracking.

54 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Bathroom overall.

55 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Bathroom vanity ceramic tile failure; cracking.

56 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Bathtub/fiberglass panel joint failure; leaking.

57 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Inadequately supported bathtub.

58 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Vinyl flooring lifting in front of tub.

59 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Shower enclosure failure; stained.

60 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Shower enclosure failure; stained tack strip carpet.

61 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Shower pan/ceramic tile joint without flexible grout.

62 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Attic access inadequate; less than 30"x 30".

63 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. 16.0 VINYL WINDOWS

64 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Window Overall

65 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Window system failure; staining.

66 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Window system failure; staining.

67 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Window system failure; staining.

68 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Vinyl window damaged during installation.

69 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Fogged dual pane window.

70 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Window installed out of square.

71 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. 17.0 ELECTRICAL

72 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Ground wires not attached.

73 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. GFI circuit overload easily tripped.

74 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. 19.0 PLUMBING

75 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Slab interior leak; requires further investigation.

76 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Improper attachment of toilet.

77 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. Plumbing leak at gas water heater.

78 R.H. ADCOCK / ARCHITECT AND ASSOCIATES, INC. The End