Honeywell Analytics Fire Alarm Aspiration Sensing Technology (FAAST) from System Sensor
2
Business Protection Earliest warning: 30-60 minutes before combustion
Unsurpassed sensitivity %/ft (.0015%/m) obscuration Competition offers .0015%/ft (.005%.m) obscuration UL listing for EWFD and VEWFD ensuring rapid response times Dual source optical smoke detection to improve detection decision making Blue LED covers the widest ranges of fires Competition use only a single infra-red laser – prone to nuisance issues Infra-red laser used to detect dust Advanced algorithms to discriminate dust from smoke
3
Business Protection Full detection strategy can be deployed
Most alarm levels 5 alarm levels can be programmed latching or non-latching 0 to 60 second delay available Monitored via Ethernet connection with static IP address notification Acclimate or Day/Night/Weekend mode Allows the system to recognize normal background in each facility setting
4
No Business Disruption
Dual light source generates data for algorithms to discriminate particulate types reducing false alarms – exclusive to FAAST Infra-red high powered laser source Particles analyzed within chamber to reject dust Exclusive Acclimate mode automatically adjusts within your specified parameters to reduce nuisance alarms and adjust to current conditions Multi-stage filtering to prevent dust and nuisance alarms Patented particle separator Replaceable 30 micron filter Electronic nuisance Rejection through algorithms
5
Reliability and Peace of Mind
5-levels of alarm level indication 10-levels of particulate indication Fault indicators exhibit a broad spectrum of events Major and Minor event notification Filter change pre-warning Ultrasonic flow detection for high and low flow events Multi-level security – access codes prevent unwanted changes to the system No hidden costs with add-on accessories – No extra charges for displays, relays, programmer, that could add up and cost you the project
6
Reliability and Peace of Mind
Dual Flow Monitoring Verification Pipe Network Ultrasonic Ensures that air is reaching detector Verifies that network has not been compromised Across Sensors Thermal Sensor, Transistors Ensures that air is traveling across sensor Verifies that air is passing through filter and across sensors
7
Reduced Lifetime Cost of Ownership
Acclimate mode allows the device to adapt to its environment within 24 hours – not up to 15 days Retrofit installations with existing pipe networks are possible eliminating the expense of starting over Superior wiring access Only 1 filter to change through the front panel door – changing every 4 years, twice as long as the market leader Particle separator removes larger contaminates before they enter the detection chamber extending the life of the device One fan with a >7 year fan life
8
Installation Ease Mounting bracket Internal Manifold Design
Provides simply, secure wall mounting provisions Save time and money Internal Manifold Design Enables pipe connection from top or bottom of the unit Simplifies under the floor pipe networks One product for above ceiling, below ceiling & below floor applications Easy Access Plug-in wiring terminals and various conduit openings Reduces time spent wiring 24 Hour vs. typical 15 day burn in time Enables the system to be up and operational in a fraction of the time
9
Pipe Network Large coverage area with a single chamber device: sq. ft. (800m2) Maximum single length of pipe 262ft (80m) Maximum amount of inlet sample holes – 40 holes Maximum length of each pipe in a two pipe network – 165ft (50m) External pipe diameter - standard ¾” inch pipe Internal pipe diameters may vary inches (15-21mm) Pipe network materials of construction may vary PVC, CPVC, ABS, Copper, Stainless, etc.
10
Example Pipe Network Sample Inlet Sample Inlets Each Pipe165ft (50m)
Single Pipe 262ft (80m) (or Max 40 inlet holes) Each Pipe165ft (50m) (or Max 20 inlet holes each) Sample Exhaust Sample Exhaust
11
Pipe Inlet Holes Sample Inlet On a single pipe network there may be a maximum of 262 feet. Inlet sample hole sizes may vary in size Range from 5/64” – ¼” (2-6mm) Travel time from the furthest hole will vary depending on application Limited to a maximum of 120 seconds by PipeIQ software PipeIQ software will guide the user through a proper installation of inlet holes and pipe layout for each application Sample Exhaust
12
Integrated Communication Advantage
Ethernet connection allows you to monitor your system from almost any location worldwide via the internet!! notification from the device of a specific alarm level, fault level, or isolate condition can be sent to up to 6 addresses PipeIQ software can configure, design pipe layouts and monitor the system 8 form C relays communicate alarm levels, urgent and minor faults and isolate; uses 3AMP programmable relays for latching and non-latching – the device controls the relays An event log tracks up to 18,000 events including alarms, faults and user actions which can be accessed via PipeIQ software or the web server interface
13
PipeIQ Software – General Tab
General facility information tab Set detection category between very early warning to non-early warning
14
PipeIQ Software – Relays and Thresholds
Set Alarm Thresholds or enable Acclimate Mode to set automatically Set Latching or Non-Latching relays Set alarm delay from 0-60 seconds
15
PipeIQ Software – Network Tab
Set various passwords to protect access to the system Set network information for Ethernet access to view on the Internet Program 6 addresses & choose when they will receive notifications
16
PipeIQ Software – Pipe Layout
Design and layout entire pipe network using PipeIQ Import CAD drawings to aid in the design Software will tailor inlet hole layout and proper hole sizing
17
Ethernet Monitoring Ethernet web-page system status monitoring – view only, no control Monitor all FAAST systems from one computer terminal –limit install costs Monitor FAAST systems from any location with Internet connection
18
Competitive Comparison Testing
Packer Engineering (Third Party) conducted side by side comparison test of the FAAST unit vs. the competition Fire test results Units alarmed within 2 to 4 seconds of each other Dust test results Competition false alarmed 9 out of 9 times FAAST immune to dust 6 out of 9 times Dust and Fire Competition false alarmed 9 out of 9 times – Never Detected Smoke FAAST immune to dust 6 of 9 times – Then Detected Smoke FAAST is 67% more immune to dust related false alarms
19
Agency Listings UL 268 Device – Air Sampling Detector
Includes DI (In-Duct) listing for ft/min air velocity FM 3230 – Smoke Detector Standard Also tested in-duct applications Report Number CSFM MSFM VdS (European) approval in process Additional agencies to follow Australia (CSIRO), Chine (CNTC), Korea, Singapore
20
Additional Resources System Sensor landing page Brochure Data Sheet Engineering Specifications Competitive Matrix Video Vignettes PipeIQ Software Download Accessories
21
FAAST Summary FAAST offers truly best-in-class very early warning aspiration smoke detection Widest range of sensitivity ( % to 6.25%/ft obscurity) Dual light sources plus advanced algorithms and patented particle separator ensure the system can discriminate between nuisance dust particles and real smoke Acclimate mode allows system to baseline facility background and continuously monitor for changes PipeIQ software easily assists in set-up and installation of a new system Design and layout entire sample pipe network using PipeIQ Software Limit install costs and monitor the system via the Internet from any location