Download presentation
1
AIR CONDITIONING ACCESSORIES
LONG LIFE PLASTIC AIR CONDITIONING ACCESSORIES Established in 1989. 120 employees. 20 injection-molding machines. vacuum machines. Assembly department. R&D department. In house mould design department. Owns about 450 moulds.
3
1. A/C indoor 2. Extension Box 3. Duct Manifolds 4. Return Air Unit 5. A/C Unit Return Air Adaptor 6. Ceiling Diffuser 7. Proportional Damper 8. Opal Thermostatic Control Unit 9. Three Way Y-elbow 10. Supply Grille 11. Return Air Grille For a Door
4
DUCT MANIFOLD 3 different types. Without air flow control flap.
With manually operated deflection flap. Duct manifold good for air conditioning up to 1100 cfm and 1800 cfm. T duct manifold.
5
DUCT MANIFOLD Made of A.B.S Corrosion - resistance
Temp. range of 0ºc-65ºc. Serves the air conditioning system distribution box. Each side can contain 1 to 4 connections of various sizes. ( option with Dampers) Lined with insulation sheets. Main duct connection has rectangular opening of 400mm x 400mm. Duct connection from 6” up to 14”.
6
MANIFOLD Ext.+EQU. AIR CONDITION UNIT EXTENSION BOX FLOWING EQUALIZER
DUCT MANIFOLD
7
MODULAR DUCT MANIFOLD
8
Duct Manifolds & Return Air A/C Adaptor 1. A/C indoor Unit
3 2 1 1. A/C indoor Unit 2. Extension Box 3. Flowing Equalizer 4. Duct Manifolds 5. Adaptor For A/C 4 5
9
Return Air Grille 1 1. Adaptor 2. R/A Grille 2
10
Return Air Grille Made of A.B.S Corrosion - resistance.
Temp. range of 0ºc-65ºc. 4 Series 220mm, 400mm, 525mm, mm and special size. With or without filters. Prevents condensation. Mounted on the wall or ceiling. One piece molded unit Curved blades 19mm spacing 30º down deflection. Frames 20 mm 30 mm. Wide frame 40mm.
11
Return Air Grille Grille without filter Grille with filter
OW-overall width NW-neck width OH-overall height NH-neck height
12
Return Air Grille for a Door
13
Round Ceiling Diffuser 1. Adaptor 2. Frame + Grille
14
Square Ceiling Diffuser 1. Adaptor 2. Opposed Blade Damper
3. Frame+ Grille
15
Round & Square Ceiling Diffuser with Net Core
16
Round Ceiling Diffuser With Damper
Made of A.B.S. Corrosion - resistance. Temp. range of 0ºc-65ºc. Consists 3 sections: Adaptor Frame Center core Distributes uniform air Out flowing air jet mixed rapidly with room air. Baffle knob manually operated of the damper.
17
Square Diffuser Round Diffuser
18
Ceiling Diffuser options
2 WAY 3 WAY ROUND
19
O.B.D for Square ceiling Diffuser
New line of opposed blade registers specially designed for ceiling diffuser. This line is equipped with adjusting handle that enables the user to control the air volume. The line uses a special adapter. Available sizes: 225x225, 330x330, 385x385 mm. Adjusting handle
20
Adaptors Prevents condensation Connects between flexible
ducts and grilles or diffusers. Dimensions of the adaptor match the Twitoplast grilles & diffusers size. All standard Adaptors. Isolation of the adapter not required . 90º Adapter Available
21
Three Way Y-Elbow
22
Three Way Y-Elbow Made of A.B.S. Corrosion - resistance.
Temp. range of 0ºc-65ºc. Convenient simple connector for outlets of flexible ducts. Equal angles of 120º between the branches. Equal pressure drop. Simple assembly. Ducts sizes from 4” up to 14”. Cams in 2 half’s
23
SUPPLY GRILLE DOUBLE DEFLECTION 1. Adaptor 2. O.B.D 3. Grille
24
SUPPLY GRILLE DOUBLE DEFLECTION Made of A.B.S. Corrosion - resistance.
Glossy colors Temp. range of 0ºc-65ºc. Size 110x990 mm 150x900 mm 200x900 mm 220x880 mm & more. Each segment consists a row of adjustable louver blades in the front and in the back.
25
Typical segment Mounted directly to the wall.
Connected to a flexible duct by an adaptor.
26
Opposed Blade Damper 1. Adaptor 2. Manual O.B.D 3. Supply Grille
2. Motorized O.B.D 3. Grille 150X300
27
STRIPLINE SUPPLAY GRILLE
Made of P.V.C Corrosion – resistance Glossy colors Neck Size 71,84,97,110,123,136mm & more. Any Length & Color
28
Round Damper Made of A.B.S. Corrosion - resistance.
Sizes : 4 , 6, 8 ,10,12 & Coming Soon 14” Temp. range of 0ºc-65ºc. Control air supply to the individual user. Flap type adjustment of 90º fully open to close. Control methods : Manual. Electrical-dimmer controller OPAL EL. Electrical thermostatic OPAL C-128DD , OPAL C-650DD Or Opal-RC11 remote control Cut Damper for Square Metal tunnel or Duct Manifold
29
Modular Dampers Assembling
30
Dampers and control units
Mechanical Operation WALL MOUNT BOX MOUNT
31
Dampers and control units
Motorized Damper Opal RC-11 REMOTE CONTROL Opal EL ELECTRIC CONTROL Opal 650DD Flush Mount Thermostat THERMOSTAIC CONTROL 128DD
32
Opal C128 DD Opal C-65DD Opal Rc-11 Ergonomic & easy to operate.
Thermostat. Or remote control (I fell)& Receiver Modern design. Can be installed as stand alone . in any existing A/C system. Heating /Cooling Selector. Automatic/manual Operation Selector. No tools required . RJ-11 Cable Connection .
33
Operation Kit for Damper Include
Basic kit 128DD includes : Part Code : Motor Damper P-3 or P-4 OPAL 128 DD Thermostat Electric cord RJ -11 ( 6 M long )
34
Power Supply C-315 Power supply C- 315-2 2 channel
35
Damper in House
36
ZC107 ZONE CONTROL system Energy Saving Up to 60%.
Controls up to 7 rooms. Plastic motorized Dampers. Communication interface to Air conditioning units. Direct Connection to Air conditioning units. Motorized & Proportional By-Pass Damper Control. Control the air supply to the individual user (room/zone). Shutoff the A/C unit when no request from the Zone’s .
37
Zone control System OPAL ZC107 3 types of operations :
• Thermostat OPAL C128DD. • Remote control OPALRC11. • Thermostat OPAL 650DD. Up to 2 compressors. Quick and easy installation No Tools required . 4 daily programs 7 days a week. Motor Damper for BY-PASS.z
38
ZC-107 Include In the Kit P.C.B C-139 C-206 Panel Control
Motor Damper P-3 or P-4 RJ-11 Cable’s for 7 Rooms
39
Installation of 4 room’s & 1 By-pass
C-206 Panel Control
40
ZC207DK ZONE CONTROL system
Energy Saving Up to 60%. Controls up to 7 rooms. Plastic motorized Dampers. Communication interface to Air conditioning units. Direct Connection to A/C P.C.B with Dry contact Inverter Compressor. Motorized & Proportional By-Pass Damper Control. Control the air supply to the individual user (room/zone). Shutoff the A/C unit when no request from the Zone’s .
41
Installation of 7 room’s & 1 By-pass
42
Dry Contact Cable
43
ZC-207 DK Include In the Kit
P.C.B C-207DK PS 200 Power Supply Motor Damper P-3 or P-4 +/- Cable’s for Motor Damper
44
C-539 Or C-539 L Universal P.C.B for A/C Include In the Kit: P.C.B
I/R Receiver Or LED's. Remote Control. For any brand of Air Conditioning. 1 Phase Or 3 Phase.
45
Comparison between A.B.S plastic & Aluminum ABS Plastic Aluminum
Corrosion resistance Corrosion Anti static Accumulation Repulsive to dust and dirt Light weight Heavier Does not sweat Sweating No dripping Dripping Easy to clean Hard to clean Colored raw material Out side painting easy screeching and rubbing Chemicals resistance Does not stand Against Chemicals Perfect look Imperfect look
46
YOUR BUSINESS WILL GROW WITH US !!!!
47
THANK YOU FOR YOUR ATTENTION
Similar presentations
© 2025 SlidePlayer.com Inc.
All rights reserved.