Presentation is loading. Please wait.

Presentation is loading. Please wait.

Product Presentation C-PTD 180/AIR/QC

Similar presentations


Presentation on theme: "Product Presentation C-PTD 180/AIR/QC"— Presentation transcript:

1 Product Presentation C-PTD 180/AIR/QC
Air-cooled Peltier Temperature System

2 Article Number and Price Configuration Example
Content Pictures Features and Benefits Specification Performance Measurements Special Features Article Number and Price Configuration Example Applications and Markets Competition Summary

3 Pictures P-CTD 180/AIR/QC

4 Features and Benefits C-PTD 180/AIR/QC
Temperature Range Complete range: 0 °C to 180 °C Measuring Systems Concentric Cylinder Measuring Systems Disposable Measuring Systems Stirrers and Spindles Air-cooled Peltier system No counter cooling necessary Typical Measurements Isothermal temperature tests Temperature ramps Temperature swing tests

5 C-PTD 180/AIR/QC - Specification
Temperature range 0 °C to 180 °C Measuring systems Standard systems, DG42 Beaker Standard beaker, max. CC39 or DG42 General Good cleanability Radiation system for counter cooling Surrounding conditions Temperature range 5 °C to 35 °C Relative humidity, not condensing < 80 % Altitude Up to 2000 m Pollution Pollution degree 2 according to EN 61010 Surrounding Laboratory, indoor us only Supply Supply voltage 85 to 265 V Frequency 50 … 60 Hz Overvoltage Overvoltage category II according to EN 6100

6 Technical Specification – Heating Rates
Comparison Peltier / Liquid Temperature Control Heating rate (Peltier): 8.0 °C/min Heating rate (Liquid): 5.0 °C/min

7 Technical Specification – Cooling Rates
Comparison Peltier / Liquid Temperature Control Cooling rate (Liquid): 0.5 °C/min Cooling rate (Peltier): 4.0 °C/min

8 Examples - Heating Stable Conditions after approx. 15 min

9 Examples - Cooling Stable Conditions after approx. 15 min

10 Wide temperature range: 0 °C to 180 °C
Special Features Wide temperature range: 0 °C to 180 °C Air cooled Peltier temperature system Rapid changes in temperature No external controller necessary No counter cooling by an external circulator Easy to install Space saving design Noise reduced

11 Peltier Temp. Control System Temp. range: 0 to 180 °C
Article Number Item-no C-PTD 180/AIR/QC Peltier Temp. Control System Temp. range: 0 to 180 °C

12 Standard Configuration
Basic Instrument RheolabQC C-PTD 180/AIR/QC Disposable Measuring System CC39/D/QC-LTD Disposable Measuring System CC27/D/QC-LTD Option: 18385 Software Rheoplus

13 Applications & Markets
Coatings: Flow Curve, Yield Point, 3ITT (Thixotropy) Food: Flow Curve, Yield Point, Temperature Test, Building Materials: Flow Curve, Yield Point,

14 Applications & Markets
Adhesives: Flow Curve, 3ITT (Thixotropy), Temperature Test Cosmetics: Flow Curve, Yield Point, Temperature Swing Test Pharma: Flow Curve, Yield Point, Soft Gels: Yield Point, 3ITT (Thixotropy) Lubricants, Oils: Flow Curve, Temperature Test Asphalt: Flow Curve, Temperature Test

15 Wide temperature range: 0 °C to 180 °C
Summary C-PTD 180/AIR/QC is the new Peltier temperature system for the RheolabQC with: Wide temperature range: 0 °C to 180 °C Air cooled Peltier temperature system Cheaper configuration compared with the liquid temp. control systems Compact design, no counter cooling by an external circulator Easy handling Small footprint Noise reduced compared to a fluid circulator Low power consumption Fast and accurate temperature setting no thermal fluids/oil necessary Firmware V1.26 for the RheolabQC required


Download ppt "Product Presentation C-PTD 180/AIR/QC"

Similar presentations


Ads by Google