VL/WL Software Offerings
Profibus DP, Modbus RTU, and BDA/BDA Plus Software
2
Available Product Software
Breaker Data Adapter (BDA) Switch ES Power A remote device for setting parameters, operating, monitoring and testing VL and WL circuit breaker trip units on the basis of HTML technology (internal software included), does not require a COM10, COM11, COM15 or COM16 communications module PROFIBUS software for COM10 and COM15, provides PROFIBUS-DP and DPV1 communication interface
3
Available Product Software
WinPM.NET Fully Integrated Power Monitoring / Power Quality Enterprise Management Software Package
4
WL and VL Circuit Breaker Interface via PROFIBUS DP with Switch ES Power
STEP7 Delivery of circuit breaker parameters to the STEP7 database via Switch ES Power (Object Manager) S7 PLC Transfer of all system data including circuit breaker parameters to SIMATIC S7 Switch ES Power PROFIBUS used as a common field bus COM15 COM10 WL with ETU745, ETU748, ETU755, or ETU776 Trip Unit VL with LCD ETU576 Trip Unit
5
Breaker Data Adapter (BDA)
Hand-held temporary mode or permanently installed mode Communication via RS232 (VL), RS485 (WL), RS232 (Notebook computer) Configuration, control, diagnostics and test of circuit breaker trip units and CubicleBUS modules Parameter print-outs available Only one BDA required for all breakers in a system Fast configuration World wide web access Cell phone paging BDA Plus unit available with Ethernet interface
6
Breaker Data Adapter (BDA) Off-line Mode
No trip unit connection required Circuit breaker parameter files are generated off-line and saved on the PC Provides opening and changing of saved parameter files One BDA required for all circuit breakers in a system Configuration and diagnostics in the office are possible No expert know-how on-site is necessary
7
Breaker Data Adapter (BDA) Temporary Hand-held Mode - Local
BDA is temporarily connected to installed trip unit Communication via RS232 (VL), RS485 (WL), RS232 (Notebook computer) Configuration, control, diagnostics and test of circuit breakers and CubicleBUS modules Parameter print outs available One BDA required for all breakers in a system On-site configuration, diagnostics and test Quick connection and set-up
8
Breaker Data Adapter (BDA) Temporary Hand-held Mode - Remote Access
Functions as in temporary hand-held mode - local Additional remote access via Modem (RS232) Remote configuration, diagnostics and test Maintenance personnel do not have to be permanently on-site Maintenance contracts can be provided by third parties
9
Breaker Data Adapter (BDA or BDA Plus) Fixed-mount mode
BDA or BDA Plus permanently connected to trip unit of WL or VL circuit breaker One BDA or BDA Plus required per circuit breaker Remote access via Ethernet Communication without communications module Especially suited for small number of circuit breakers in infrastructure or industry segments