Presentation is loading. Please wait.

Presentation is loading. Please wait.

PRIMERGY Installation

Similar presentations


Presentation on theme: "PRIMERGY Installation"— Presentation transcript:

1 PRIMERGY Installation
Release July, 2007 PRIMERGY Installation RAID Basics Fujitsu Siemens Computers training documentation [Name of the chapter as on the agenda] © Fujitsu Siemens Computers [Year]

2 PRIMERGY Installation
Release July, 2007 SAS/SATA Comparison RAID Basics PRIMERGY Installation Release November © Fujitsu Siemens Computers All rights reserved [Name of the chapter as on the agenda] © Fujitsu Siemens Computers [Year]

3 Disk Interface Comparison
PRIMERGY Installation Release July, 2007 Disk Interface Comparison Source: Fujitsu RAID Basics PRIMERGY Installation Release November © Fujitsu Siemens Computers All rights reserved [Name of the chapter as on the agenda] © Fujitsu Siemens Computers [Year]

4 Mixing of SAS and SATA Disks
PRIMERGY Installation Release July, 2007 Mixing of SAS and SATA Disks RAID Basics PRIMERGY Installation Release November © Fujitsu Siemens Computers All rights reserved [Name of the chapter as on the agenda] © Fujitsu Siemens Computers [Year]

5 PRIMERGY Installation
Release July, 2007 RAID Basics RAID Basics PRIMERGY Installation Release November © Fujitsu Siemens Computers All rights reserved [Name of the chapter as on the agenda] © Fujitsu Siemens Computers [Year]

6 PRIMERGY Installation
Release July, 2007 What is RAID ? Redundant Array of Independent Disks A way of organizing several disks to provide performance OR resilience: Tolerant to a disk failure Types of RAID: Standard: Level 0 - 5 Vendor Specific: 7 > Associated technology Hot plug Hot Spare More about RAID and RAID sizing on Student CD disk_subsystem_sizing_-_raid_controller_1.0__en_.pdf RAID Basics PRIMERGY Installation Release November © Fujitsu Siemens Computers All rights reserved [Name of the chapter as on the agenda] © Fujitsu Siemens Computers [Year]

7 RAID Level 1+0 (10): Striped Mirrored Sets
PRIMERGY Installation Release July, 2007 RAID Level 1+0 (10): Striped Mirrored Sets Resilience Reads Host System Cost Writes Disk Array Controller (DAC) Data Disk 1 Mirrored Disk 1 Data Disk 1 Mirrored Disk 1 RAID Basics PRIMERGY Installation Release November © Fujitsu Siemens Computers All rights reserved [Name of the chapter as on the agenda] © Fujitsu Siemens Computers [Year]

8 RAID Level 7: JBOD – Just a bunch of disks
PRIMERGY Installation Release July, 2007 RAID Level 7: JBOD – Just a bunch of disks Just a way of declaring normal disks under a RAID controller. (May include COD information) Host System Disk Array Controller (DAC) JBOD RAID Basics PRIMERGY Installation Release November © Fujitsu Siemens Computers All rights reserved [Name of the chapter as on the agenda] © Fujitsu Siemens Computers [Year]

9 RAID 1E: An LSI specific Level
PRIMERGY Installation Release July, 2007 RAID 1E: An LSI specific Level Mirroring over more than two disks. During the “Mylex era” this was called Mylex-RAID 6, This is confusing since there is a standard RAID level called RAID6 that has a completely different function Host System Disk Array Controller (DAC) 1 1 2 2 3 3 4 4 Data Disk 1 Data Disk 2 Data Disk 3 RAID Basics PRIMERGY Installation Release November © Fujitsu Siemens Computers All rights reserved [Name of the chapter as on the agenda] © Fujitsu Siemens Computers [Year]

10 PRIMERGY Installation
Release July, 2007 Software RAID Support Standard O/S Support Windows 2000/2003 includes RAID 0, 1 & 5 Netware offers RAID 0, 1, 5 & 10 Unixware offers Online Storage Manager (0, 1, 0+1 & 5) Redhat & Suse Linux Include RAID 0, 1 & 5 Fujitsu-Siemens products DDM, Duplex Data Manager, Includes RAID 1 w Hot-spare (Important for MS Cluster configuration ) Implications of Software RAID RAID 5/3 needs a Math Co-processor (for parity creation) RAID often not supported on System/boot Partition (Except for FSC DDM) No instant fail-over ( Except for FSC DDM) Hot-Plug Support requires HW Control Mechanism. RAID Basics PRIMERGY Installation Release November © Fujitsu Siemens Computers All rights reserved [Name of the chapter as on the agenda] © Fujitsu Siemens Computers [Year]

11 PRIMERGY Installation
Release July, 2007 HW RAID Cache Policy Write back Only enable with BBU or UPS Support Write Through Does not use cache Big Impact on Parity RAID performance Predictive cache (Read Ahead pattern matching) (for RAID disable it) Switch off – most requests are not synchronous Cache Size Must Support BBU for a weekend. Larger cache boosts parity raid if using write back policy RAID Basics PRIMERGY Installation Release November © Fujitsu Siemens Computers All rights reserved [Name of the chapter as on the agenda] © Fujitsu Siemens Computers [Year]

12 PRIMERGY Installation
Release July, 2007 RAID 2,5 “ and 3,5 “ RAID Basics PRIMERGY Installation Release November © Fujitsu Siemens Computers All rights reserved [Name of the chapter as on the agenda] © Fujitsu Siemens Computers [Year]

13 PRIMERGY RX300/RX200 S3 - 2.5-inch HDD
PRIMERGY Installation Release July, 2007 PRIMERGY RX300/RX200 S inch HDD RX200 S3 2 x 3.5” Hot-plug HDD RX300 S3 6 x 3.5” Hot-plug HDD 4 x 2.5” Hot-plug HDD 12 x 2.5” Hot-plug HDD 2 x 2.5” Hot-plug HDD TX120 RAID Basics PRIMERGY Installation Release November © Fujitsu Siemens Computers All rights reserved [Name of the chapter as on the agenda] © Fujitsu Siemens Computers [Year]

14 PRIMERGY Installation
Release July, 2007 SATA / SAS HDDs 06/2007 Size Technology Rotation Capacity 3,5" SAS 15k 36, 73, 146, 300 GB 2,5" 36, 73 GB 10k 36, 73, 146,300 GB 36, 73, 146 GB SATA 7.2k 80, 160, 250, 500, 750 GB RAID Basics PRIMERGY Installation Release November © Fujitsu Siemens Computers All rights reserved [Name of the chapter as on the agenda] © Fujitsu Siemens Computers [Year]

15 PRIMERGY Installation
Release July, 2007 SCSI/ SATA / SAS HDD and Controllers SAS HDD SATA HDD R 0/1/10 R5/50 TX150 S5 SATA Base Unit - Onboard LSI MegaSR =ICH7R ICH 7R + ibutton option (Windows only) or LSI MegaRAID SATA 8308ELP (Altair) SAS Base Unit Onboard LSI 1068 IME MegaRAID ZCR-SAS - LSI 8300XLP TX200 S3 Onboard ESB2 Onboard ESB2 + ibutton Or RAID5 Embedded MegaRAID SW LSI ZCR-SAS - LSI 8300XLP Onboard LSI 1068 IME (p) TX300 S3 RX300 S3 (Common Base Unit) LSI MegaRAID SAS ROMB RX100 S4 Embedded SATA software RAID ICH7R (R 0/1) RX200 S3 Three iButton solutions 1. Onboard LSI MegaSR (ICH7R) + iButton 2. Onboard LSI 1068 IME + iButton 3.Onboard LSI 1068 IME + IOP332 + iButton +256 MB = ROMB The system is equipped with on-board RAID controller IOP332 I/O processor (Brockton). Together with the on-board 8-port LSI 1068 SAS-controller the server contains a full featured RAID controller for SAS / SATA HD´s. It supports the RAID level 0, 1, 10, 5 and 50 if the RAID functionality is enabled by the SAS onboard RAID controller. RAID Basics PRIMERGY Installation Release November © Fujitsu Siemens Computers All rights reserved [Name of the chapter as on the agenda] © Fujitsu Siemens Computers [Year]

16 LSI RAID Controller on Board
PRIMERGY Installation Release July, 2007 LSI RAID Controller on Board RAID Basics PRIMERGY Installation Release November © Fujitsu Siemens Computers All rights reserved [Name of the chapter as on the agenda] © Fujitsu Siemens Computers [Year]

17 TX200 S3 onboard SATA RAID 1/0 with ESB2
PRIMERGY Installation Release July, 2007 TX200 S3 onboard SATA RAID 1/0 with ESB2 ESB2 = RAID 0/1 + opt Key for RAID5 Enterprise Southbridge2 (ESB 2) SAS / SATA you can extend the LSI IME 1068 onboard controller with the iButton to a full functional RAID controller which supports RAID 5 and enhances the Performance with a cache module Motherboard RAID Basics PRIMERGY Installation Release November © Fujitsu Siemens Computers All rights reserved [Name of the chapter as on the agenda] © Fujitsu Siemens Computers [Year]

18 TX200 S3 onboard SATA RAID 1/0 with ESB2
RAID Basics PRIMERGY Installation Release November © Fujitsu Siemens Computers All rights reserved

19 PRIMERGY Installation
Release July, 2007 RX300 S3 onboard IME RAID 1/1E PCI-X 133 SAS Ctrl. LSI 1068 SAS / SATA you can extend the LSI IME 1068 onboard controller with the iButton to a full functional RAID controller which supports RAID 5 and enhances the Performance with a cache module Motherboard RAID Basics PRIMERGY Installation Release November © Fujitsu Siemens Computers All rights reserved [Name of the chapter as on the agenda] © Fujitsu Siemens Computers [Year]

20 PRIMERGY Installation
Release July, 2007 LSI SAS Raid To enter the controller press <CTRL+C> RAID Basics PRIMERGY Installation Release November © Fujitsu Siemens Computers All rights reserved [Name of the chapter as on the agenda] © Fujitsu Siemens Computers [Year]

21 PRIMERGY Installation
Release July, 2007 LSI SAS Raid Automatic Rebuild Supports Hot Spare Disk RAID Basics PRIMERGY Installation Release November © Fujitsu Siemens Computers All rights reserved [Name of the chapter as on the agenda] © Fujitsu Siemens Computers [Year]

22 RX300 S3 onboard RAID5 with INTEL Brockton IOP block diagram
PRIMERGY Installation Release July, 2007 RX300 S3 onboard RAID5 with INTEL Brockton IOP block diagram Modules with BBU have Charge Circuit integrated Standard DDR2-533 / 667 DIMM Module 256 MB ECC with BBU ( 72 Std. hold time ), 256 MB without BBU PCI- Express PCI-X 133 SAS Ctrl. LSI 1068 SAS / SATA you can extend the LSI IME 1068 onboard controller with the iButton to a full functional RAID controller which supports RAID 5 and enhances the Performance with a cache module IOP (Intel Brockton) iButton (Raid Key) Flash ROM Raid Firmware Stack (LSI) Motherboard RAID Basics PRIMERGY Installation Release November © Fujitsu Siemens Computers All rights reserved [Name of the chapter as on the agenda] © Fujitsu Siemens Computers [Year]

23 PRIMERGY Installation
Release July, 2007 LSI Web BIOS The LSI Web BIOS is accessed with <CTRL + H> during the boot sequence. If several LSI controllers are installed, they will all be accessible from the menu. RAID Basics PRIMERGY Installation Release November © Fujitsu Siemens Computers All rights reserved [Name of the chapter as on the agenda] © Fujitsu Siemens Computers [Year]

24 LSI pluggable PCI RAID Controllers
PRIMERGY Installation Release July, 2007 LSI pluggable PCI RAID Controllers RAID Basics PRIMERGY Installation Release November © Fujitsu Siemens Computers All rights reserved [Name of the chapter as on the agenda] © Fujitsu Siemens Computers [Year]

25 LSI controller naming LSI MegaRAID SAS abcd ab--> Type,
c --> external SAS connections d --> internal SAS connections Example LSI MegaRAID SAS 8344ELP 83 Type 4 external connections 4 internal connections RAID Basics PRIMERGY Installation Release November © Fujitsu Siemens Computers All rights reserved

26 pluggable RAID controller
Onboard RAID extension (ZCR) 8300XLP LSI MegaRAID SATA 8803ELP LSI MegaRAID SAS 8344ELP For disk Expansion with SX40 LSI MegaRAID SCSI 320-2x For disk Expansion with SX30 RAID Basics PRIMERGY Installation Release November © Fujitsu Siemens Computers All rights reserved

27 PRIMERGY Installation
Release July, 2007 LSI Web BIOS The LSI Web BIOS is accessed with <CTRL + H> during the boot sequence. If several LSI controllers are installed, they will all be accessible from the menu. RAID Basics PRIMERGY Installation Release November © Fujitsu Siemens Computers All rights reserved [Name of the chapter as on the agenda] © Fujitsu Siemens Computers [Year]

28 pluggable RAID controller
Onboard RAID extension (ZCR) 8300XLP RAID Basics PRIMERGY Installation Release November © Fujitsu Siemens Computers All rights reserved

29 PRIMERGY Installation
Release July, 2007 Zero Channel RAID ZCR card must be in correct slot that has the logic to enable it to utilise the onboard SCSI or SAS Most modern FSC motherboards colour code this blue Match LSI ZCR with LSI chip on motherboard Tx150S5,RX200S3 and Tx200S3 Embedded RAID Logic (EMRL): (the Adaptec term for it) SISL (the term LSI use) When the ZCR Controller is plugged in the dedicated PCI Slot, the EMRL activates the ChipSelect function for the AIC7901 / 7901 SCSI chip. By activating this function the SCSI Chip isn‘t shown on the PCI Bus any more. Aditionally the Interrupt channel is changed from a direct connection to the CPU to a connection to the ZCR Controller. So any operation is led directly to the RAID Controller which works off the requests LSI operates with S2 system boards with LSI chips... they tend to use the term SISL (SCSI Interrupt Steering Logic). Except that a different system board is involved with LSI chips, the operation is equivalent. SAS PCI RAID Basics PRIMERGY Installation Release November © Fujitsu Siemens Computers All rights reserved [Name of the chapter as on the agenda] © Fujitsu Siemens Computers [Year]

30 pluggable RAID controller
LSI MegaRAID SAS 8344ELP For disk Expansion with SX40 RAID Basics PRIMERGY Installation Release November © Fujitsu Siemens Computers All rights reserved

31 LSI MegaRAID SAS 8344ELP For disk Expansion with SX40
PRIMERGY Installation Release July, 2007 LSI MegaRAID SAS 8344ELP For disk Expansion with SX40 Customer Rules Only FibreCAT SX40 disk drives are released. SAS drives from FibreCAT SX60/80 are not compatible! Controller is released for FibreCAT SX40 connection only Controller is not released for internal connection Max. SAS cable length between controller – box / box – box is 2 m FibreCAT SX40 must be up before power on of connected controller/server and Controller/server must be powered off before FibreCAT SX40 Redundant path configurations (using two I/O-Modules) are not released Controller is not released for use as a shared Cluster device in Cluster Configurations It is strongly recommended to save RAID configurations with MegaCLI Controller Hotplug is not released FibreCAT SX40 Hotplug is not released Tape devices and optical devices (e.g. DVD) are not supported OS boot from FibreCAT SX40 will be supported with next major release Replacing a Hot Spare by a new hard disk, this new hard disk stops being handled as Hot Spare in SAS firmware. You need to reconfigure this new hard disk as Hot spare. RAID Basics PRIMERGY Installation Release November © Fujitsu Siemens Computers All rights reserved [Name of the chapter as on the agenda] © Fujitsu Siemens Computers [Year]

32 RAID Options *reboot during Capacity extension and RAID migration is not allowed RAID Basics PRIMERGY Installation Release November © Fujitsu Siemens Computers All rights reserved

33 PRIMERGY Installation
Release July, 2007 Lab - General Lab General Explain Signs Explain Shares \\ xx.200\Download\ RAID Basics PRIMERGY Installation Release November © Fujitsu Siemens Computers All rights reserved [Name of the chapter as on the agenda] © Fujitsu Siemens Computers [Year]

34 PRIMERGY Installation
Release July, 2007 Lab – General RAID Basics PRIMERGY Installation Release November © Fujitsu Siemens Computers All rights reserved [Name of the chapter as on the agenda] © Fujitsu Siemens Computers [Year]

35 PRIMERGY Installation
Release July, 2007 Exercise 02 Configure LSI IME SAS and SATA RAID Basics PRIMERGY Installation Release November © Fujitsu Siemens Computers All rights reserved [Name of the chapter as on the agenda] © Fujitsu Siemens Computers [Year]

36 PRIMERGY Installation
Release July, 2007 Exercise 03 Configure LSI Web BIOS RAID Basics PRIMERGY Installation Release November © Fujitsu Siemens Computers All rights reserved [Name of the chapter as on the agenda] © Fujitsu Siemens Computers [Year]