1 DARTS – Engineer/Test Cell Users
July 2, 2018 Cummins Internal Use Only

2 Topics DARTS Overview DARTS Data Movement – Overview DARTS Path
What are not allowed in DARTS Cyflex Version Send Data from Cyflex to DARTS Steady-State Data dlogger Send DATA from Indicom to DARTS AVL Set up Contact Information Appendix – Setting Up Concerto Cummins Internal Use Only

3 DARTS Overview DARTS is short for Data Analysis ReposiTory System
DARTS is the PAM replacement ++ More types of data will included in the future such as Emissions, etc. Like PAM Steady state headers Datapoints MUA data Better than PAM RAPID dlogger Indicom ifiles ECFG / XCAL (on Z drive) ECM parameters / units* Enhanced USER keywords* Central Node Test Cell DARTS * Coming late 2018 – requires CyFlex 6.3

4 DARTS Data Movement – Overview
Configuring Cyflex Central Node for DARTS During transition period, Data will be sent to both DARTS and PAM. Cummins Internal Use Only

5 DARTS Path DARTS requires the following keywords:
Program has to be valid DARTS program (or McParts engine family), refer to: Valid Programs for DARTS DARTS Path engine_specs pam_specs dlogger_specs afix avl_link Engine Program Code program C_PROGRAM @PROGRAM “$program” Test Name test_type C_TEST_TYPE @TEST_TYPE “$test_type” Test Mode Name mode C_MODE @MODE “$mode” Test Data Group Name group C_GROUP @GROUP Test ID @TEST_ID “$tpid” or “$Test_ID” tpid or Test_ID Group by Date* group_by_date C_GROUP_BY_DATE * ‘Group by date’ is a flag to DARTS to turn off auto date grouping Cummins Internal Use Only

6 DARTS Path (Cont.) The DARTS Path can be thought of as a folder to contain data For Steady-State data, a header with the DARTS path needs to be sent before sending datapoints (i.e. create the DARTS folder to contain the data) Run eng_specs If Datapoint files are sent with no header: Datapoint files will be stored in hold folder Errors will be displayed on the DARTS Job Status page Datapoint files need to be resent after Header was sent to DARTS Cummins Internal Use Only

7 What’s not allowed in DARTS
Duplicate keywords in a datapoint is not allowed Same keyword with different valid suffix or extension ‘.’ are not considered duplicate. PAM groups are not supported in DARTS DARTS paths are the replacement Probably will want to set group_by_date to ‘false’ to prevent auto group dating Make it sub-bullet point for suffix Only preferred keyword will be in DARTS, PAM aliases will not be in DARTS Cummins Internal Use Only

8 Sending Steady-State Data
DARTS path need to be updated in the engine_specs file Edit /specs/engine_specs.nnn file (nnn refers to the test cell number) Add program, test_type, mode, group parameters Optionally, add group_by_date parameter. If set to FALSE it will inhibit DARTS from grouping by date Run eng_specs command This creates ‘folder’ in the DARTS landing zone Check on DARTS Job Status page to verify if header file is successfully loaded Cummins Internal Use Only

9 Sending Steady-State Data
Example of engine_specs.nnn: DARTS Paths information DARTS Paths information Cummins Internal Use Only

10 Sending Steady-State Data
Example of engine_specs.nnn: “group_by_date” if set to FALSE – This will inhibit DARTS from grouping by date. Cummins Internal Use Only

11 Sending Steady-State Data
Update pam_spec file, add DARTS path and group_by_date labels Labels should be the same with engine_specs. Cummins Internal Use Only

12 Sending Steady-State Data
Run take_dum_fr after pam_specs is updated Check on DARTS Job Status page, to verify if datapoint file is successfully loaded Notes: ** The Program label must be set to a valid DARTS program name (usually the same as the McParts engine family name) ** The values of test_type, mode, and group labels must be set as per best practices defined by the test team leader Cummins Internal Use Only

13 Sending Dlogger Data Dlogger is similar to floger, except
dlogger data will automatically be sent to DARTS Requires DARTS path information Requires DARTS (PAM) keywords as channels Cummins Internal Use Only

14 Sending Dlogger Data Dlogger Setup: Create dlogger spec file
Example dlogger spec file content: Dlogger ID DARTS Path Cummins Internal Use Only

15 Sending Dlogger Data Example dlogger spec file content:
“group_by_date” if set to FALSE – This will inhibit DARTS from grouping by date. Cummins Internal Use Only

16 Sending Dlogger Data Dlogger Setup:
Dlogger ID is unique to the machine If Dlogger is stopped and then restart without changing Dlogger ID, the data will be appended to the previous data log Run the dlogger from the command line: dlogger specFileName Stop the dlogger, if needed Check on DARTS Job Status page, to verify if dlogger file is successfully loaded * For more detail on dlogger, visit Logging Data Using dlogger on ewiki Cummins Internal Use Only

17 Indicom – AVL Setup Open a parameter file Cummins Internal Use Only

18 Indicom – AVL Setup Select the parameter file you want to use and click “Open” Cummins Internal Use Only

19 Indicom – AVL Setup – User Variables
Adding new DARTS keywords (program, test_type, mode, group). Click on Extras | User Variables. Cummins Internal Use Only

20 Indicom – AVL Setup – Add User Variables
Click “New” to add new variables ‘%’ required to be in front of the name Variable names spelling must match For detail instruction: Automated_iFile_processing_for_DARTS.PDF Cummins Internal Use Only

21 Indicom – AVL Setup – Save Script
Set up the Save Script Click on “Measurement Control” Cummins Internal Use Only

22 Indicom – AVL Setup – Save Script
Set up Save Script – Extras Tab Click on “Extras” tab Click on the check box at “Use the following save script” Cummins Internal Use Only

23 Indicom – AVL Setup – Save Script
Set up Save Script – select script file Select “DartsSaveScript” from drop down list Then Click “OK” Cummins Internal Use Only

24 Indicom – AVL Setup – Save Parameter
Save parameter file required after completing set up save script Save: Parameter file to save under the same name. Or Save As, to save under new name. Cummins Internal Use Only

25 DARTS Contact Joe Suever (joseph.d.suever@cummins.com)
For questions please contact: Joe Suever Nareeya Kaewfanapadon ) To report issues: Follow instructions here: DARTS Support - How to Report Issues Cummins Internal Use Only

26 Q+A

27 Appendix Cummins Internal Use Only

28 Connecting Concerto To DARTS
This is manual process for users whom already had Concerto installed 1. At Concerto window, Click at “Data Explorer Cummins Internal Use Only

29 Connecting Concerto to DARTS
2. Click at “New Data Source” button to open Data Source Definition Cummins Internal Use Only

30 Connecting Concerto to DARTS
Cummins Internal Use Only

31 Connecting Concerto to DARTS
3. Select Data Source and click on “Next” Cummins Internal Use Only

32 Connecting Concerto to DARTS
4. Enter in Server Name: ods.darts.cummins.com 6. Select “4.1 / 5 (Corba)”. Once selected “RPC Number” field will Get replaced by “Port” and “Context” 5. Select “ASAM Server (Generic or Santorin)” Cummins Internal Use Only

33 Connecting Concerto to DARTS
6. Enter in Port “2809” 7. Select Database. For engine, Select “ENGINE_CLN.ASAM-ODS” Cummins Internal Use Only

34 Connecting Concerto to DARTS
8. Click on “Next” Cummins Internal Use Only

35 Connecting Concerto to DARTS
9. Login with: Username: WWID Password: LDAP Password Cummins Internal Use Only

36 Connecting Concerto to DARTS
To see all data, click “OK”. Else enter in Attribute for filter condition. Cummins Internal Use Only

37 Connecting Concerto to DARTS
Data appears under ASAM ODS Database Cummins Internal Use Only