Download presentation
Presentation is loading. Please wait.
1
DRS219 Sales Presentation
INTERNAL USE ONLY OCT 2019 DRS219 Sales Presentation Dynamic Reflux Sampler Customer Presentation: External use only
2
Agenda Introducing the New DRS219 product features and benefits
Typical applications Key considerations from customers Product overview Product positioning within ABB portfolio Product coding and availability Summary January 26, 2020
3
Introducing the NEW DRS219
Rugged design, high performance clean samplers for use in hazardous area applications
4
Introducing the DRS219 Rugged design, high performance clean samplers for use in hazardous area applications Product overview The DRS is essentially a fixed temperature distillation derived from the need to remove water as a condensable component from low boiling point gases. Cooling is provided by way of a vortex cooler controlled by an electronic temperature controller. The sample temperature input for control of the cooling operation is a sensor placed directly in the sample path. Since the cooling capacity of the vortex cooler is essentially fixed, the flow rate of the conditioned sample exiting the DRS is also limited and dependent on the water/ condensable content of the inlet gas. It is designed to provide simple, fast and highly accurate sample conditioning analysis for severe process applications. Features: -Electronic PID, self-tuning -Tight temperature control for higher accuracy -Higher sample flow for faster analysis -Reduce maintenance, all components field serviceable January 26, 2020
5
Introducing the DRS219 High sample throughput, precise temperature control, certified for hazardous areas The NEW DRS219 Increased process efficiency The DRS219’s scalability and flexibility enables customers to achieve increased efficiency through simpler operation, greater user flexibility and reduced maintenance and operation Hazardous area approval Global hazardous area approvals ensures ABB customers peace of mind wherever they operate in the world. Type approval certificate for IECEx, NEPSI . ATEX is in proceeding. Ease of use The DRS219 is simple with no moving parts and reliable of overall system provided this in a standardized package January 26, 2020
6
DRS219 typical applications
Rugged design, high performance clean samplers for use in hazardous area applications Petrochemical Chemical Oil & Refinery Gas Plant Ethylene furnace measurement Ammonia processes Acetylene Fluidized cat cracker Syngas Process Naphtha cracker furnace gas January 26, 2020 Slide 6 6
7
Key considerations from our customers when selecting instrumentation
DRS219 Market Requirements Health & Safety Environment Conditions Easy Installation Cost Efficiency and Quality Products meeting global hazardous certification minimizing risk & cost IECEx & NEPSI Ex IIB+H2 T3 Gb Ex d IIB+H2 T3 Note: ATEX is in Progress, available by end of Y2019 Dependability ensuring optimal performance and environ-mental compliance Temp: -20 °C to 55 °C (-4 °F to 131 °F) Ingress Protection Rating: IP66 Simple, easy-to-use products requiring minimal training and upkeep. Process flange type installation as standard industry practices for easy site installation. Reliability of dynamic reflux sampler is enhanced which reduces the costs of analyzer system maintenance across the overall installation. Globally ABB DRS installation and practices. January 26, 2020
8
Key features and benefits
Product overview Key features and benefits
9
Suitability design High sample throughput, precise temperature control, certified for hazardous areas The DRS219 offers advantages in classically difficult applications by supporting the basic principles of sample conditioning. Easy installation Sample inlet -2 inches ANSI class 150# standards.(Also available in other ANSI connections) Sample outlet- ¼ tube fittings, Flow Rate max. 500 process contains 50% (volume percentage) water vapor Service Port available Simple Utilities Power requirement-120VAC to 240VAC,50/60HZ Power Consumption: 45VA Instrument Air supply-1/2 tube fitting, Max. 30 SCFM , pressure barg, plant grade Safety area classification Type Ex Examination IECEx, and NEPSI (ATEX will be available by end of Y2019) Ingress Protection Rating IP66 Suitability design for strategic flexibility January 26, 2020
10
Increasing your process efficiency
Optimizing plant availability Suitable design for strategic flexibility The Dynamic Reflux Sampler (DRS) supports a reliable analyzer system installation with the “keep it simple” approach in mind. The unit is a self-contained sampling device suitable for mounting at or near the process pipeline tap, thereby eliminating the need for sample conditioning before sample transport occurs. Primary sample conditioning occurs in a virtually in-situ fashion with the DRS approach. Condensable components are removed and are used to support particulate removal before they can present problems in the sample transport system’s downstream components and the analyzer. Benefits include Air cooling is provided by way of a vortex cooler controlled by an electronic temperature controller. A sensor placed directly in the sample path for sample temperature input for control of the cooling operation Electronic PID, self-tuning and pre-setting program for cooling capacity of the vortex cooler dependent on the water/condensable contents of the inlet gas and the flow rate of the conditioned sample exiting the DRS. January 26, 2020
11
Product positioning DRS219 Vs DRS2170
12
Direct replacement for the DRS2170
January 26, 2020
13
Building on the success of a well loved product
DRS2170 Vs DRS219 Key Features Features DRS2170 DRS219 Benefits Electrical Standard NEC Standard Conduit box IEC Standard Armored cable with barrier glands Cost efficiency Flexible installation and configuration Enclosure Aluminium casting NEMA 4X / IP65 IP66 Reduce maintenance, all components field serviceable Cooling Air Cooling version Liquid cooled version available Simple version with multiply choice of process connection Option choice for Temperature output for remote monitoring Ambient temperature range 0-60 DECG DECG Low temperature endure Communications RS485 PC monitoring and setup with RS485 communications and software available Approvals NEC and CSA Class I, gas groups B,C,D; division 1;T3 rate(160DECG) ATEX Category 2 Zone 1;CE II2G,Ex dm[ia] ia IIB+H2 T4 rate(145DECG) IECEx and NEPSI Ex IIB+H2 T3 Gb Ex d IIB+H2 T3 (ATEX will be available by end of Y2019) Conforms to the latest hazardous area testing procedures and directives Hart 7 benefits over Hart 5 include: long tag name, time stamped data, and measurement status January 26, 2020
14
Product Coding & Availability
Simplified ordering
15
DRS219 – Simplified Ordering
Product DRS219- Series No.:3K67DRS219xxxx Main Ordering Information Additional/Optional Ordering Code DRS219 Dynamic Reflux Sampler DRS219 Base revision 2” 150# ANSI RF Flange Process Connection 2” 300# ANSI RF Flange 2” 600# ANSI RF Flange 2” 900# ANSI RF Flange 3” 150# ANSI RF Flange 3” 300# ANSI RF Flange 3” 600# ANSI RF Flange 3” 900# ANSI RF Flange Freight-CPT (Air Freight) Optional ordering code Quench Section Insulation Remote Temperature 4-20mA Output Wetted Material Other Materials available (Factory quote requirement) Documentation (supplied as standard in English) Hardcopy Documentation EN Materials Certification Type 3.1 Factory Acceptance Test - Local W/Hands On Training 1 DAY (MAX. 5 UNITS PER BATCH) Certificate of Origin (By Chamber of Commerce) January 26, 2020
16
DRS219 – Simplified Ordering
Spares; Modules DRS219 Electrical Parts Part Number Temperature Controller 3KXGDRS219U0200 Pressure Booster 3KXGDRS219U0400 Solenoid Valve 3KXGDRS219U0500 I2P Transducer 3KXGDRS219U0300 RTD Sensor 3KXGDRS219U0900 DRS219 Mechanical Parts Pneumatic Valves 3KXGDRS219U1100 2-way ball valve 3KXGDRS219U1200 Special Vortex Tube 3KXGDRS219U0600 Mechanical parts (Flange gasket ,bolts, nut) 3KXGDRS219U0150 Pressure Regulator,4-50 PSI, Bar 3KXGDRS219U1300 DRS219 Commissioning Parts Part Number Capacitance,0.1 uF +/--20% 3KXGDRS219U0800 Fuse,230V,200mA (6.3 x31.5) 3KXGDRS219U0250 Fuse,150V,400mA (6.3 x31.5) 3KXGDRS219U0350 DRS219 Consumables Rasching Ring 3KXGDRS219U0450 January 26, 2020
17
Summary
18
Clean samples for your process analyzer
DRS219 Clean samples for your process analyzer DRS219 The low maintenance, high performance for Dynamic Reflux Samper Electronic PID, self-tuning Tight temperature control for higher accuracy Higher sample flow for faster analysis Reduce maintenance, all components field serviceable Simple to use, maintain and support Global hazardous area approvals-IECEx and NEPSI Cost-efficiency and Flexible installation and configuration Global ABB Service and product lifecycle management January 26, 2020
19
January 26, 2020
Similar presentations
© 2025 SlidePlayer.com Inc.
All rights reserved.