1 ELECTRICAL SAFETY  

2 ELECTRICAL INSPECTION
THE FOLLOWING EXAMPLES ARE INTENDED TO ASSIST THE BUILDING MANGER IN DETERMINING THE DEGREE OF COMPLIANCE, WTHIN HIS/HER OPERATIONS AND ACTIVITIES AND THE ASSOCIATED ELECTRICAL HAZARDS IN THEIR BUILDINGS. ALL DESIGN AND INSTALLATION OF EQUIPMENT AND FACILITES SHALL BE IN ACCORDANCE WITH APPLICABLE NEC, OSHA, DOE, AND SLAC POLICIES AND PROCEDURES.

3 INSPECT WORK AREA FOR ELECTRICAL HAZARDS DAILY, SHOULD INCLUDE, BUT NOT LIMITED TO THE FOLLOWING:
EXTENSION CORDS ·     FRAYED OR WORN

4 · GROUND PIN INPLACE (MISSING)
·     CONTINUOUS LENGTHS; NO DAISY-CHAINING

5 ·     ACCEPTABLE

6 ·     UNACCEPTABLE

7 BY FOOT OR VEHICLE TRAFFIC
·     PROTECT FROM DAMAGE INCLUDING THAT CAUSED BY FOOT OR VEHICLE TRAFFIC

8 “NO OBSTRUTION WITHIN 36 INCHES”
ELECTRICAL PANELS “NO OBSTRUTION WITHIN 36 INCHES” ·     IS THERE SUFFICIENT CLEARANCE AROUND ELECTRICAL EQUIPMENT?

9 GFCI (GROUND FAULT CIRCUIT INTERRUPTER)
GFCI (GROUND FAULT CIRCUIT INTERRUPTER) ·     WITHIN SIX FEET OF SINKS AND EXTERIOR DOORS; ON METAL-SURFACED WORKBENCHES; ON OUTDOOR RECEPTACLES

10 · OUTDOOR WEATHERPROOF COVER (MISSING)

11 · TEST MONTHLY IF PRACTICAL

12 JUNCTION BOXES, AND UNUSED HOLES.
PROTECTIVE COVERS ·     GUARDING OF ENERGIZED PARTS TO PREVENT ACCIDENTAL CONTACT; OVER POWER PANELS, JUNCTION BOXES, AND UNUSED HOLES.

13 ELECTRICAL PANEL DIRECTORIES
·     IN PLACE AND ACCURATE AND POWER CABINETS AND BREAKERS PROPERLY LABELED

14 · ALERT THE OCCUPANTS OF THE PLANNED WORK
ENERGIZED WORK ·     ALERT THE OCCUPANTS OF THE PLANNED WORK ·     WARNING SIGNS AND BARRICADES ·     PPE (PERSONAL PROTECTIVE EQUIPMENT)

15 · DEVICE ATTACHED TO PREVENT OPERATION
LOCKOUT & TAGOUT ·    DEVICE ATTACHED TO PREVENT OPERATION

16 OTHER HAZARDS/VIOLATIONS
·     RACEWAY CANNOT BE USED TO SUPPORT LOW VOLTAGE OR LIMITED ENERGY CABLES ·     GROUNDING & BONDING OF CABLE TRAYS

17 · OVERLOADED POWER STRIP · METAL LADDER IN AREA WHERE EXPOSED
ENERGIZED PARTS ARE PRESENT

18 · UNQUALIFIED PERSONS SHALL NOT TAMPER WITH BUILDING ELECTRICAL WIRING
MAINTENANCE & REPAIRS ·     UNQUALIFIED PERSONS SHALL NOT TAMPER WITH BUILDING ELECTRICAL WIRING

19 ELECTRICAL SAFETY IS EVERYONE’S
RESPONSIBILITY ! ·     REDUCING & ELIMINATING EXPOSURE TO ELECTRICAL HAZARDS REQUIRES YOUR CONSTANT ATTENTION