Presentation is loading. Please wait.

Presentation is loading. Please wait.

IEEE/EMB/11073 Status Report for Combined Working Group Meeting

Similar presentations


Presentation on theme: "IEEE/EMB/11073 Status Report for Combined Working Group Meeting"— Presentation transcript:

1 IEEE/EMB/11073 Status Report for Combined Working Group Meeting
Tom Thompson, Program Manager, Operations Program Management 11 January 2019

2 Current Projects - PoCD
PAR Number Project Type PAR Expiration Ballot Close Date Status P Revision 12/31/2019 1/13/2019 Sponsor Ballot: Comment Resolution P b Amendment WG Draft Development P a P New 12/31/2020 4 Active PARs 1 Draft in ballot, & 3 Drafts in Development

3 Standards - PoCD 10 Active Standards
Standard Number Year Committee SASB Expiration 2008 EMB/11073/LL Inactive 2004 EMB/11073 a 2015 EMB/11073/PoCD 12/31/2025 2012 12/31/2022 2017 12/31/2027 EMB/11073/EMBS_WG 2018 12/31/2028 2016 12/31/2026 2000 12/31/2020 a 2011 12/31/2021 2010 10 Active Standards 4 Inactive Standards as of 25 January 2019 IEEE Std FDIS ballot closed 11 January 2019

4 Current Projects - PHD PAR Number Project Type PAR Expiration
Ballot Close Date Status P Revision 12/31/2019  12/04/2018 Sponsor Ballot: Comment Resolution P 12/31/2020 WG Draft Development P  11/25/2018 P P P 12/31/2022 P 12/05/2018 P P P

5 Current Projects – PHD Con’t
PAR Number Project Type PAR Expiration Ballot Close Date Status P New 12/31/2019 WG Draft Development P 12/31/2021 P Revision 12/31/2022  12/6/2018 Sponsor Ballot: Comment Resolution P 12/31/2020 P 11/23/2018 15 Active PARs 8 Drafts in ballot & 7 Draft Development

6 Standards - PHD Standard Number Year Committee SASB Expiration 2012 EMB/11073/PHD 12/31/2022 2008 Inactive 2011 12/31/2021 2015 12/31/2025 /Cor 1 2017 12/31/2027 2010 12/31/2020* 2016 12/31/2026 2014 12/31/2024 /Cor 1 2013 12/31/2023* Note:* has been added to notate there is PAR associated this standard and it is in sponsor ballot.

7 Standards – PHD Con’t 17 Active Standards
Standard Number Year Committee SASB Expiration 2008 EMB/11073/PHD Inactive 2010 12/31/2020* 2014 12/31/2024 /Cor 1 2015 12/31/2025 17 Active Standards 6 Inactive Standards as of 25 January 2019 2 Standards in ballot at ISO IEEE Std FDIS ballot closed 11 January 2019 IEEE Std FDIS ballot closed 21 January 2019 Note:* has been added to notate there is PAR associated this standard and it is in sponsor ballot.

8 Ballot Highlights PoCD
10101 Standard for ISO/ :2004, Health Informatics - Point-of-Care Medical Device Communication – Nomenclature Recirculation 2 ends 13 January 2019 10201 Health Informatics - Point-of-Care Medical Device Communication - Domain Information Model Standard approved 4 December 2018

9 Ballot Highlights PHD 10404 REV Pulse Oximeter
Comment Resolution from Recirculation 3 10407 REV Blood Pressure Monitor 10408 REV Thermometer 10415 REV Weighing Scale 10419 REV Insulin Pump Comment Resolution from Recirculation 2

10 PHD Ballot Highlights (Con’t)
10442 REV Strength Fitness Equipment Comment Resolution from Recirculation 2 20601 REV Optimized Exchange Protocol–Recirc 1 Comment Resolution from Recirculation 5 10471 REV Independent Living Activity Hub Comment Resolution

11 EMB/11073 Executive Summary
SASB Approvals, January 2018 P REV – Glucose Meter P REV – Insulin Pump P REV – Continuous Glucose Monitor SASB Approval, March 2018 P REV - Strength fitness equipment No SASB Submittals, April/May or June 2018 SASB Approvals – September 2018 20701 Service-Oriented Medical Device Exchange Architecture & Protocol Binding No SASB Submittals, October 2018 SASB Approvals – December 2018 10201 Health Informatics – Point-of-Care Medical Device Communication – Domain Information Mode Next Opportunity: Deadline: 8 February 2019 for March 2019 SASB

12 PoCD Standards Expiring 31 December 2019
, Health informatics -- Point-of-care medical device communication -- Part 10101: Nomenclature, Revision PAR active until 2019, Sponsor ballot closed 13 January 2019 b, Health informatics -- Point-of-care medical device communication -- Part 10101: Nomenclature Amendment 2: Additional definitions, Revision PAR active until 2019 a, Health informatics--Point-of-care medical device communication Part 10103: Nomenclature--Implantable device, cardiac Amendment 1: Additional definitions, Revision PAR active until 2019

13 PHD Standards Expiring 31 December 2019
, Health Informatics - Personal Health Device Communication - Part 10404: Device Specialization - Pulse Oximeter, Revision PAR active until 2019, Comment Resolution , IEEE Health Informatics - Personal Health Device Communication - Device Specialization - Blood Pressure Monitor, Revision PAR active until 2019, Comment Resolution , IEEE Health informatics--Personal health device communication Part 10408: Device specialization – Thermometer, Revision PAR active until 2019, Comment Resolution , IEEE Health Informatics - Personal Health Device Communication - Device Specialization - Weighing Scale, Revision PAR active until 2019, Comment Resolution

14 PHD Standards Expiring 31 December 2019
, Health Informatics - Personal Health Device Communication Part 10420: Device Specialization - Body Composition Analyzer, Revision PAR active until 2019 , Health Informatics -- Personal Health Device Communication - Part 10424: Device Specialization -- Sleep Apnoea Breathing Therapy Equipment (SABTE), Revision PAR active until 2019 , Health Informatics - Personal Health Device Communication - Device Specialization - Home Healthcare Environment Ventilator, Revision PAR active until 2019 , Health Informatics -- Personal Health Device Communication - Part 20601: Application Profile - Optimized Exchange Protocol, Revision PAR active until 2019, Comment Resolution

15 ISO Adoptions Status Balloting Update
– FDIS ballot closes 11 January 2019 – FDIS ballot closes 11 January 2019 – FDIS ballot closes 21 January 2019 – To be submitted (awaiting publication) – Adopted and published

16 Collaborative Relationships
LOINC MoU IEEE/HL7 IHE MoU NIST Category A Liaison with ISO/TC215 Category A Liaison with ISO/TC121

17 2019 SASB Meetings

18 Contact Information Tom Thompson IEEE 445 Hoes Lane Piscataway, NJ Phone:


Download ppt "IEEE/EMB/11073 Status Report for Combined Working Group Meeting"

Similar presentations