Presentation is loading. Please wait.

Presentation is loading. Please wait.

Project Readiness Review P10029 – Air Muscle Artificial Limb

Similar presentations


Presentation on theme: "Project Readiness Review P10029 – Air Muscle Artificial Limb"— Presentation transcript:

1 Project Readiness Review P10029 – Air Muscle Artificial Limb
Zachary R. Wessner (M.E.) May 13, 2009

2 Project Information Project Name Air Muscle Artificial Limb Project Number P10029 Project Family Artificial Organ Track Biomedical Systems and Technologies Start Term End Term Faculty Guide / Primary Customer Dr. Kathleen Lamkin-Kennard(ME) - Confirmed Faculty Consultant Ed Hanzlik (ME) - Confirmed Air Muscle

3 Mission Statement: Project Family: Objective
What: Scalable Robotic Hand [powered by air muscles] Intuitive Control System Why: Microsurgical Applications Large Scale Industrial Maintenance Variety of Usable Environments

4 Project Family: Overview
(P08023)- Three finger hand (left) (P08024)- Five finger grasping hand (center) (P09023)- Five finger hand platform (right) (P09029)- Simulated control model - wrist and elbow

5 Mission Statement: P10029: Objective
What: Continuation on P09023 / P09029 Qualitative (visual) → Quantitative (measurable) Improved Control System: Feedback / User Interface Why: Increased Knowledge Research Platform Future Projects: Application Oriented Design - Scalability Image sources: P09023 / P09029

6 Affinity Diagram: Data Collection
Raw Data Collection MSD Teams Leaks in Air Muscles Feedback Control Covering of Hand Goal - ASL Imagine RIT Technical Guide Systems Engineering Calibration Measure of Success Metrics Customer Project Family Vision Next Iteration Feedback Virtual Simulation Testing Controls Competitive Benchmarking Control Utility Degrees of Freedom Accuracy of Movements Size

7 Function Tree: What does this project need to do?
Research Platform Controls System Interface Development Feedback Loop Physical Functionality Characterization Virtual Simulation Verification

8 System Overview Image Source: P09023

9 Data Acquisition Overview
Image Source: P09023

10 Work Distribution - System Level
High Control System Medium Data Acquisition Low Physical Hand System

11 Measure of Success Set Based Concurrent Approach:
User Input Function Library Control System Output Verification Final Goal: Function Accuracy Feedback Intermediate Goal: Positional Accuracy First Goal: Consistent Functionality

12 Proposed Function Concept

13 Staffing Name Discipline Responsibility Zach Wessner
Mechanical Engineering Project Manager - Controls System (Controls Background / LabView) Electrical Engineering Controls System (Programming) Virtual Simulation (SolidWorks / LabView) (Systems Engineer) Interface Development

14 Required Resources Project Space
Meeting Space - Senior Design Center (need to submit request) Laboratory Space - Building 9 Biomedical Lab (confirmed) Time MSD1 & MSD Week Development 20091 / (Fall / Winter) Funding Project Budget = $500 (confirmed) Equipment / Assets P09023 Physical Prototype (confirmed) P09023 / P09029 Programs / Documentation (confirmed) SolidWorks / LabView software license seats (confirmed) Mechatronics Software Toolkit / SolidWorks COSMOSmotion (confirmed) Computers (2) - (confirmed) Spare Parts / Air Muscles (confirmed) Personnel Five Member Multidisciplinary Team (TBA) M.E. (4) E.E. (1) Customer / Faculty Guide : Dr. Lamkin-Kennard (confirmed) Technical Guide: Ed Hanzlik (confirmed)

15 Work Break Down Structure
Controls System Exploration Benchmarking Concept Generation Virtual System Define Scope Physical System Repair / Modifications Week 1 Week 2 Week 3 System Architecture Plan (Concurrent Design Strategy) Week 4 M.E. / E.E. M.E.

16 Risk Assessment Description Consequences Probability Severity
Overall Risk Contingency Plan Understaffed Deadlines not met, project not successful M H Establishing a lean staffing request in addition to equal distribution of workload and proactive planning. Physical Prototype Breaks Half of the research platform does not function L Rebuild using readily available components. Utilize virtual model for controls evaluation. Hand can not perform ASL A new function library must be generated. Evaluate physical capabilities early, plan a set-based concurrent architecture within the project. Use functions the physical prototype is capable of performing.

17 References P09023 P09029 Dr. Lamkin-Kennard Ed Hanzlik


Download ppt "Project Readiness Review P10029 – Air Muscle Artificial Limb"

Similar presentations


Ads by Google