Presentation is loading. Please wait.

Presentation is loading. Please wait.

Innovative/Alternative Septic System Performance

Similar presentations


Presentation on theme: "Innovative/Alternative Septic System Performance"— Presentation transcript:

1 Innovative/Alternative Septic System Performance
System Performance and Tracking it with the Carmody Database Barnstable County Department of Health and Environment

2 Permit Breakdown by Town and System Type
By The Numbers Permit Breakdown by Town and System Type

3 Probability Density Graph (“Bell Curve”)
Box-Whisker Diagrams What are they? Min/Max Value Min/Max Value Box Median – Middle Value Whiskers 50% 25% 25% Probability Density Graph (“Bell Curve”)

4 Box-Whisker Diagrams What Can We Use Them For? A B C D
A – A “Good” System. Box and whiskers are short and compact. B – A “Bad” System. Results are all over the place. Box and whiskers are stretched out. C – A “Consistently Bad” System. Compact but well above TN limit (19 mg/l) D – A “Usually Pretty Good” System. Compact but maybe a couple of high results. A B C D

5 Single Family all Types by Individual System
Three or More Samples with Full Nitrogen Series 123 systems with 3 or more TN samples 96 (78%) with median TN <19 mg/l

6 Single Family all Types by System Type
Three or More Samples with Full Nitrogen Series

7 Single Family Advantex
Three or More Samples with Full Nitrogen Series 27 systems with 3 or more TN samples 21 of 27 (78%) with median TN <19 mg/l

8 Single Family Amphidrome
Three or More Samples with Full Nitrogen Series 4 systems with 3 or more TN samples 3 of 4 (75%) with median TN <19 mg/l

9 Single Family Bioclere
Three or More Samples with Full Nitrogen Series 43 systems with 3 or more TN samples 32 of 43 (74%) with median TN <19 mg/l

10 Three or More Samples with Full Nitrogen Series
Single Family FAST Three or More Samples with Full Nitrogen Series 442 systems with 3 or more TN samples 355 of 442 (80%) with median TN <19 mg/l

11 Three or More Samples with Full Nitrogen Series
Single Family JET Three or More Samples with Full Nitrogen Series

12 Single Family MicroSepTech
Three or More Samples with Full Nitrogen Series

13 Three or More Samples with Full Nitrogen Series
Single Family Orenco Three or More Samples with Full Nitrogen Series

14 Three or More Samples with Full Nitrogen Series
Single Family OMNI RSF Three or More Samples with Full Nitrogen Series 51 systems with 3 or more TN samples 30 of 51 (51%) with median TN <19 mg/l

15 Single Family Generic RSF
Three or More Samples with Full Nitrogen Series 16 systems with 3 or more TN samples 9 of 16 (56%) with median TN <19 mg/l

16 Three or More Samples with Full Nitrogen Series
Single Family RUCK Three or More Samples with Full Nitrogen Series 22 systems with 3 or more TN samples 11 of 22 (50%) with median TN <19 mg/l

17 Single Family Septitech
Three or More Samples with Full Nitrogen Series 45 systems with 3 or more TN samples 15 of 45 (33%) with median TN <19 mg/l

18 Single Family Singulair
Three or More Samples with Full Nitrogen Series 90 systems with 3 or more TN samples 81 of 90 (90%) with median TN <19 mg/l

19 Single Family Waterloo Biofilter
Three or More Samples with Full Nitrogen Series 11 systems with 3 or more TN samples 7 of 11 (64%) with median TN <19 mg/l

20 Nitrex System at 15 Dory Lane, Eastham
Influent versus Effluent Total Nitrogen Design Flow = 9,900 gpd 40 Houses at Buildout 30 Houses currently occupied, with 6 seasonal

21 Single Family all Types by System Type
Three or More Samples with Full Nitrogen Series System Type Total with 3+ Samples Total below 19mg/l Percentage All Types 761 569 75% Advantex 27 21 78% Amphidrome 4 3 Bioclere 43 32 74% FAST 442 355 80% OMNI RSF 51 30 51% RSF (Generic) 16 9 56% RUCK 22 11 50% Septitech 45 15 33% Singulair 90 81 90% Waterloo 7 64%

22 Keeping Track of it All…
Quickly Identifying Poorly Performing Systems Sample Reports Use to obtain a list of the most recent sample exceedances (anything over 19 mg/l) Two 25% Exceedances Use to generate a list of systems with two samples exceeding 19mg/l by 25% (24mg/l). One 50% Exceedance Use to generate a list of systems with one sample exceeding 19 mg/l by 50% (30 mg/l)

23 Keeping Track of it All…
Sample Reports Messages Amount of the Exceedance Exceedance Percentage Exceeding Parameter Number of Consecutive Exceedances 25.83 mg/L > 19mg/L(36%) for Total Nitrogen 1 Consecutive 4 Non-Consecutive (25.83,8.54,43.4,29.35,24.1) Number of Non-Consecutive Exceedances Results from the Last Five Samples

24 Keeping Track of it All…
Quickly Identifying Poorly Performing Systems Sample Reports Use to obtain a list of the most recent sample exceedances (anything over 19 mg/l) Two 25% Exceedances Use to generate a list of systems with two samples exceeding 19mg/l by 25% (24mg/l). One 50% Exceedance Use to generate a list of systems with one sample exceeding 19 mg/l by 50% (30 mg/l)

25 Keeping Track of it All…
Sample Exceedance Report Select the Report Type: 2 over 24mg/l, 1 over 30mg/l or merged report. Export the current list to MS EXCEL List of the last 5 samples Remove the flag for this system. Will reappear on this list with another exceedance.

26 Keeping Track of it All…
Exporting the Sample Exceedance Report to EXCEL System ID Home Owner Municipality Sampling History EASte595FAS Savage, Joseph 595 Steele Road Eastham,MA Eastham /7/ /12/ /14/ /9/ /21/2007 EAR06420ADV Seatoller LLC, Steve Lang 4205 State Highway Route 6 Eastham,MA /9/ /1/ /5/2011 EATur265FAS St. Aubin, Lucille and Carol 265 Turnip Road Eastham,MA /27/ /27/ /26/ /17/ /25/ /27/2006 EATur245FAS St. Aubin, Lucille and Carol 245 Turnip Road Eastham,MA /8/ /10/ /23/ /4/ /21/2007

27 Town of Eastham Sample Exceedance Report - 3/29/2011
Keeping Track of it All… “Cleaned Up” Sample Exceedance Report Town of Eastham Sample Exceedance Report - 3/29/2011 System ID Home Owner Municipality Sampling History Median Average StDev EASam300Sep Baughman, James and Amanda 300 Samoset Road Eastham,MA Eastham /26/2010 /28/2010 /28/2009 /28/2009 /29/2008 21.085 EASun093Adv Bechgaard, Candace 93 Sunset Avenue /2/2011 /27/2010 /26/2010 /28/2010 /27/2009 17.05 18.272 EAR06418RSF Brown, Robert 4180 Route 6 /2/2010 /20/2009 /9/2008 /23/2007 /3/2006 40.1 41.962 EACam760FAS Civita, George 760 Campground Road North Eastham,MA North Eastham /21/2008 77 6/9/2008 /18/2007 /14/2007 40 10/3/2006 56.7 65.65 EABri220Bio Conlin, Kevin 220 Bridge Road /5/2011 /19/2010 /8/2010 /13/2009 /2/2009 21.06 24.398 Exceedance reports will be delivered semi-annually. BOH will decide what action to take, since each BOH will likely have a different policy.

28 Innovative/Alternative Septic System Performance
System Performance and Tracking it with the Carmody Database Barnstable County Department of Health and Environment


Download ppt "Innovative/Alternative Septic System Performance"

Similar presentations


Ads by Google