Presentation is loading. Please wait.

Presentation is loading. Please wait.

More and more power failures are being experienced through the Republic of South Africa. It is clear that this situation is not improving, nor will it.

Similar presentations


Presentation on theme: "More and more power failures are being experienced through the Republic of South Africa. It is clear that this situation is not improving, nor will it."— Presentation transcript:

1 More and more power failures are being experienced through the Republic of South Africa. It is clear that this situation is not improving, nor will it improve in the foreseeable future. The negative impact of these power outages is being felt more frequently in both the commercial and industrial sectors of our economy. Where extended alternative power is required to run lighting, air conditioners and UPS systems a generator is essential. Alpha Power has a full range of petrol and diesel generators to cater for a specific need.

2 VOLVO PENTA STANDARD SPECIFICATIONS:
ENGINE VOLVO PENTA heavy duty diesel engine Resolution: 1500rpm Water cooled Tropical type radiator ALTERNATOR VDE 0530 & IEC 34-I standardizations Automatic Voltage Regulation (AVR) Overload Acceptance: 110% for 1 hour, 150% for 2 minutes Short-circuit Resistance: 300% for 10 seconds Insulation Class: H Insulation Resistance:1800V AC Voltage: 23I/400V AC Voltage Regulation: +/- 1% Frequency: 50Hz MANUAL CONTROL PANEL Electronic Control Panel Ammeter Voltmeter Voltage Commutator Engine Coolant temperature indicator Engine oil pressure indicator Counter for time totaliser Relays Warning lamps and fuses Emergency Stop button CHASSIS Mounted on the steel base chassis Elastic vibration dampers between engine and chassis Fuel tank located in chassis Dial type mechanical fuel indicator AUTOMATIC CONTROL PANEL Electronic control panel Battery Charger CANOPY Designed for easy lifting and moving Metal parts are coated with electrostatic polyester powder painted Thermally insulated exhaust system Acoustic insulation

3 94KVA 109KVA 142KVA 167KVA 205KVA 226KVA 85KVA 100KVA 130KVA 152KVA
STAND-BY OUTPUT 94KVA 109KVA 142KVA 167KVA 205KVA 226KVA PRIME OUTPUT 85KVA 100KVA 130KVA 152KVA 186KVA BRAND VOLVO PENTA MODELS TD530GE TAD531GE TAD532GE TAD731GE TAD732GE TAD733GE STAND-BY POWER 82.5KW 97.8KW 125.5KW 149.2KW 179KW 197KW PRIME POWER 75KW 89.8KW 114.5KW 136.2KW 162KW NO OF CYLINDERS 4 6 AIR INDUCTION SYSTEM TURBO CHARGED TURBO AAC* GOVERNOR MECHANICAL ELECTRONIC COOLING TYPE WATER COOLED FUEL CONSUMPTION AT ½ LOAD 9.4 LT/HR 11.1 LT/HR 14.2 LT/HR 16.3 LT/HR 19.7 LT/HR 21.5 LT/HR FUEL CONSUMTION AT FULL LOAD 18.7 LT/HR 21.7 LT/HR 28.4 LT/HR 31.5 LT/HR 38.9 LT/HR 43.1 LT/HR FUEL TANK CAPACITY 258 LT 501 LT TURBO AAC*: TURBO CHARGED, AIR TO AIR AFTER COOLED

4 94KVA 109KVA 142KVA 167KVA 205KVA 226KVA 1100 MM (1100) 1100MM (1100)
STAND-BY OUTPUT 94KVA 109KVA 142KVA 167KVA 205KVA 226KVA WIDTH W/O CANOPY; (W/CANOPY) 1100 MM (1100) 1100MM (1100) 1200MM (1200) LENGTH W/O CANOPY; (W/CANOPY) 2100MM (2800) 2800MM (3800) HEIGHT W/O CANOPY; (W/CANOPY) 1450MM (1800) 1600MM (1800) 1600MM (2150) 1700MM (2150) 1900MM (2150) WEIGHT W/O CANOPY; (W/CANOPY) 1200KG (1635) 1265KG (1915) 1500KG (2080) 1600KG (2190) 1750KG (2520)

5 PERKINS STANDARD SPECIFICATIONS:
ENGINE PERKINS heavy duty diesel engine Resolution: 1500rpm Water cooled Tropical type radiator ALTERNATOR VDE 0530 & IEC 34-I standardizations Automatic Voltage Regulation (AVR) Overload Acceptance: 110% for 1 hour, 150% for 2 minutes Short-circuit Resistance: 300% for 10 seconds Insulation Class: H Insulation Resistance:1800V AC Voltage: 23I/400V AC Voltage Regulation: +/- 1% Frequency: 50Hz MANUAL CONTROL PANEL Electronic Control Panel Ammeter Voltmeter Voltage Commutator Engine Coolant temperature indicator Engine oil pressure indicator Counter for time totaliser Relays Warning lamps and fuses Emergency Stop button CHASSIS Mounted on the steel base chassis Elastic vibration dampers between engine and chassis Fuel tank located in chassis Dial type mechanical fuel indicator AUTOMATIC CONTROL PANEL Electronic control panel Ammeter Voltmeter Voltage Commutator Engine Coolant temperature indicator Engine oil pressure indicator Counter for time totaliser Relays Warning lamps and fuses Emergency Stop button Battery Charger CANOPY Designed for easy lifting and moving Metal parts are coated with electrostatic polyester powder painted Thermally insulated exhaust system Acoustic insulation

6 305KVA 358KVA 412KVA 450KVA 506KVA 559KVA 630KVA 277KVA 326KVA 375KVA
STAND-BY OUTPUT 305KVA 358KVA 412KVA 450KVA 506KVA 559KVA 630KVA PRIME OUTPUT 277KVA 326KVA 375KVA 409KVA 462KVA 509KVA 570KVA BRAND VOLVO PENTA MODELS TAD940 GE TAD941GE TAD1241GE TAD1242GE TAD1640GE TAD1641GE TAD1642GE STAND-BY POWER 265KW 308KW 354KW 387KW 432KW 473KW 536KW PRIME POWER 240KW 279KW 323KW 352KW 393KW 430KW 485KW NO OF CYLINDERS 6 AIR INDUCTION SYSTEM TURBO AAC* GOVERNOR ELECTRONIC COOLING TYPE WATER COOLED TURBO AAC*: TURBO CHARGED, AIR TO AIR AFTER COOLED

7 305KVA 358KVA 412KVA 450KVA 506KVA 559KVA 630KVA 29.1 LT/HR 34.1 LT/HR
STAND-BY OUTPUT 305KVA 358KVA 412KVA 450KVA 506KVA 559KVA 630KVA FUEL CONSUMPTION AT ½ LOAD 29.1 LT/HR 34.1 LT/HR 37.8 LT/HR 41.2LT/HR 46.6 LT/HR 50.8 LT/HR 57.3 LT/HR FUEL CONSUMTION AT FULL LOAD 56.7 LT/HR 66.3 LT/HR 75.2 LT/HR 82 LT/HR 89.6 LT/HR 100 LT/HR 114.1 LT/HR FUEL TANK CAPACITY 664 LT 664 LT 918 LT WIDTH W/O CANOPY; (W/CANOPY) 1500 MM (1500) 1500MM (1500) LENGTH W/O CANOPY; (W/CANOPY) 3100MM (4200) 3500MM (4600) HEIGHT W/O CANOPY; (W/CANOPY) 1950MM (2350) 2100MM (2700) WEIGHT W/O CANOPY; (W/CANOPY) 2240KG (3230) 2350KG (3354 2800KG (3870) 2820KG (3870 3080KG (4220) 3220KG (4360) 3260KG(4400) TURBO AAC*: TURBO CHARGED, AIR TO AIR AFTER COOLED

8 8.8KVA 11KVA 18KVA 27.5KVA 44KVA 55KVA 62KVA 83KVA 8KVA 10KVA 16.5KVA
STAND-BY OUTPUT 8.8KVA 11KVA 18KVA 27.5KVA 44KVA 55KVA 62KVA 83KVA RATED OUTPUT 8KVA 10KVA 16.5KVA 25KVA 40KVA 50KVA 56KVA 75KVA BRAND PERKINS MODELS 403C-11G 403C-15G 404-22G 1103A-33G 1103A-33TG1 1103A-33TG2 1104A-44TG1 1104A-44TG2 STAND-BY POWER 8KW 11.6KW 18.2KW 26.4KW 39.7KW 58KW 62.9KW 77.4KW RATED POWER 7.2KW 10.5KW 16KW 24KW 35KW 52.8KW 57.2KW 70.4KW NO OF CYLINDERS 3 4 AIR INDUCTION SYSTEM NATURALY ASPIRATED GOVERNOR MANUAL TURBO AAC*: TURBO CHARGED, AIR TO AIR AFTER COOLED

9 8.8KVA 11KVA 18KVA 27.5KVA 44KVA 55KVA 62KVA 83KVA WATER COOLED
STAND-BY OUTPUT 8.8KVA 11KVA 18KVA 27.5KVA 44KVA 55KVA 62KVA 83KVA COOLING TYPE WATER COOLED FUEL CONSUMTION AT FULL LOAD 10.9 LT/HR 13.5 LT/HR 20.5 LT/HR 30.7 LT/HR 42.7 LT/HR 59.1 LT/HR 67.3 LT/HR 76.4 LT/HR FUEL TANK CAPACITY WIDTH W/O CANOPY 552MM 714MM 750MM 752MM LENGTH W/O CANOPY 1320MM 1770MM 1870MM 1970MM 2070MM 2149MM HEIGHT W/O CANOPY 1258MM 1368MM WEIGHT W/O CANOPY 396KG 456KG 710KG 810KG 860KG 930KG 990KG TURBO AAC*: TURBO CHARGED, AIR TO AIR AFTER COOLED

10 220KVA 253KVA 275KVA 200KVA 230KVA 250KVA PERKINS 1006TG2A 1006TAG
STAND-BY OUTPUT 220KVA 253KVA 275KVA RATED OUTPUT 200KVA 230KVA 250KVA BRAND PERKINS MODELS 1006TG2A 1006TAG 1006TAG2 1306C-E87TAG2 1306C-E87TAG4 1306-E87TAG6 STAND-BY POWER 224KW 246KW RATED POWER 205KW 221KW NO OF CYLINDERS 6 AIR INDUCTION SYSTEM TURBO CHARGED GOVERNOR ELECTRONIC TURBO AAC*: TURBO CHARGED, AIR TO AIR AFTER COOLED

11 220KVA 253KVA 275KVA WATER COOLED 194.1 LT/HR 220.5 LT/HR 248.2 LT/HR
STAND-BY OUTPUT 220KVA 253KVA 275KVA COOLING TYPE WATER COOLED FUEL CONSUMTION AT FULL LOAD 194.1 LT/HR 220.5 LT/HR 248.2 LT/HR FUEL TANK CAPACITY WIDTH W/O CANOPY 1003MM LENGTH W/O CANOPY 2953MM HEIGHT W/O CANOPY 1717MM WEIGHT W/O CANOPY 2015KG 2100KG 2215KG TURBO AAC*: TURBO CHARGED, AIR TO AIR AFTER COOLED

12 400KVA 450KVA 500KVA 550KVA 700KVA 800KVA 350KVA 635KVA 730KVA PERKINS
STAND-BY OUTPUT 400KVA 450KVA 500KVA 550KVA 700KVA 800KVA RATED OUTPUT 350KVA 635KVA 730KVA BRAND PERKINS MODELS 2306C-E14TAG2 2306C-E14TAG3 2506A-E15TAG1 2506A-E15TAG2 2806A-E18TAG1A 2806A-E18TAG2 STAND-BY POWER 353KW 396KW 400KW 434KW 546KW 634KW RATED POWER 388KW 435KW 445KW 483KW 607KW 711KW NO OF CYLINDERS 6 AIR INDUCTION SYSTEM TURBO CHARGED GOVERNOR ELECTRONIC TURBO AAC*: TURBO CHARGED, AIR TO AIR AFTER COOLED

13 400KVA 450KVA 500KVA 550KVA 700KVA 800KVA WATER COOLED 341.9 LT/HR
STAND-BY OUTPUT 400KVA 450KVA 500KVA 550KVA 700KVA 800KVA COOLING TYPE WATER COOLED FUEL CONSUMTION AT FULL LOAD 341.9 LT/HR 387.3 LT/HR 435.5 LT/HR LT/HR 567.8 LT/HR 681.9 LT/HR FUEL TANK CAPACITY WIDTH W/O CANOPY 1110MM 1150MM 1536MM 1912MM LENGTH W/O CANOPY 3601MM 3700MM 3785MM 4111MM 4280MM HEIGHT W/O CANOPY 2065MM 2197MM 2098MM 2285MM WEIGHT W/O CANOPY 3235KG 3300KG 3750KG 3800KG 4727KG 6059KG TURBO AAC*: TURBO CHARGED, AIR TO AIR AFTER COOLED


Download ppt "More and more power failures are being experienced through the Republic of South Africa. It is clear that this situation is not improving, nor will it."

Similar presentations


Ads by Google