1 IRRADIATION FACILITIES at SCKCEN Nuclear Belgian Research Center Boeretang, 200 2400 Mol Belgium
Benoît Brichard Instrumentation Department Tel: Secr: Fax: Ooms Hans Instrumentation Department Tel: Secr: Fax:

2 Quick overview Neutron Facilities Gamma Facilities I. Cobalt-60 I. BR1
KIRSTEN 80 kGy/h BRIGITTE 25 kGy/h CMFA1 20 kGy/h CMFA2 20 kGy/h RITA 2 kGy/h CAL Gy/h II. Spent Fuels GEUSE II 0.5 kGy/h Neutron Facilities I. BR1 Maximum Thermal flux 3x1011 n/cm2s II. BR2 1x1015 n/cm2s Maximum Fast Flux 7x1014 n/cm2s Installations Air cooled design Vacuum design

3 The irradiation facilities of SCKCEN cover a wide range of radiation processing and nuclear applications

4 Low Gamma Dose Rate Irradiation Facilities
GEUSE II RITA

5 Large irradiation volume with moderate dose-rate
RITA 0.5 => 1.5 kGy/h Dose Rate  Energy (MeV) Relative Intensity 60Co - spectrum Under water facility 380 mm 600 mm Temperature up to 150 °C Inert gas or air On-line instrumentation facilities

6 CRISTALES: In-pile section for photonics assessment
Standard on line instrumentation 3 thermocouples type K Heating element Signal cables Rinsing of the chamber Extra on line instrumentation Fibers Coax, extra thermocouples Power cables Instrumentation on demand

7 Large irradiation volume with moderate dose-rate
GEUSE II Large irradiation volume with moderate dose-rate Dose Rate 10 => 500 Gy/h 137Cs - spectrum Under water view Relative Intensity 900 mm 380 mm  Energy (MeV) Temperature up to 200 °C Inert gas or air On-line instrumentation facilities

8 Vacuum System Module for RITA and GEUSE II
VSM Design for polymer irradiation Active low-vacuum Pressure (mbar) Time (h) 10-6 mbar 200 mm 600 mm

9 High Gamma Dose Rate Irradiation Facilities
CMF A2 CMF A1 A2 A1 B BRIGITTE C3 KIRSTEN The four irradiation positions are located in the BR2 containment building

10 Large irradiation volume
at high dose-rate BRIGITTE 0.5 => 25 kGy/h Dose Rate  Energy (MeV) Relative Intensity 60Co - spectrum Side view Container open 900 mm 220 mm Temperature up to 200 °C Inert gas or air On-line instrumentation facilities

11 Polymer irradiation Testing in Brigitte

12 Open Capsule with heater
Medium irradiation volume at high dose-rate CMF-A1 CMF-A2 Open Capsule with heater 0.5 => 20 kGy/h Dose Rate  Energy (MeV) Relative Intensity 60Co - spectrum Capsule 900 mm 80 mm Temperature up to 200 °C Inert gas or air On-line instrumentation facilities

13 Small irradiation volume
at high dose-rate KIRSTEN Dose Rate 80 kGy/h (57 MGy/Month)  Energy (MeV) Relative Intensity 60Co - spectrum 200 mm 35 mm No control of environmental parameters Uniform dose rate over 100 mm Only temperature monitoring

14 Climate Chamber for ageing tests
CLARA Climate Chamber for ageing tests Available Volume 2 m3 Temperature control -36 to 180 °C Humidity control 10 to 98 % Convenient Facility for pos-irradiation temperature testing

15 Low dose-rate irradiation facility
CAL Low dose-rate irradiation facility Bunker Inside View Output Source View Room temperature control at 21°C Atmosphere and humidity control Max Dose Rate: 1 Gy/h

16 Material Testing Reactor – BR2

17 Moving Irradiation Rig
BR2: Material Testing Reactor – 56 MW Neutronic Performances in n/cm2s and Gamma Heating W/g[Al] Thermal Flux 2.8x1014 Gamma Heating Core Reflector 7x1014 Fast Flux (En > 0.1 MeV) 200 mm < 50 mm 84 mm 50 mm 10-15 W/g 7x1013 1.4x1014 7x1012 2.4x1014 1-4 W/g SIDONIE Moving Irradiation Rig 1x1014 5 x 1013 ~ 3 W/g 6x1013

18 BR1: Gas Cooled reactor – 700 kW to 1MW
Standard value at 700 kW BR1, operated on day by day basis Graphite moderator Typical temperature: 40 °C -70 °C Neutron and gamma standard fields Thermal flux : 3.5x1011n/cm2s Fast Flux : 2 x 1010 n/cm2s FUNIN – Fast neutron boost module Fast Neutron in Y6 channel ~ 1011 n/cm2 s U-235 fission spectrum Volume 80 mm2 External Cavity – 1 m diameter load with uranium sphere Fast Flux 2-4 x 108 n/cm2 possibility for Gamma Converter


Download ppt "Benoît Brichard Instrumentation Department Tel: Secr: Fax: Ooms Hans"