Presentation is loading. Please wait.

Presentation is loading. Please wait.

IRRInet-M IRRInet-ACE Product Introduction

Similar presentations


Presentation on theme: "IRRInet-M IRRInet-ACE Product Introduction"— Presentation transcript:

1 IRRInet-M IRRInet-ACE Product Introduction
Presented By: AK Updated: Dec 2, 2007

2 Upon completion of this presentation, you should be able to:
Understand all HW options Understand all Configuration options Understand Migration of new HW into legacy systems Understand all Models and Options Understand all about on-site programming tool (Pocket-PC)

3 IRRInet-M - General View
IRRInet-M AC 24VAC Power In (AC) Commonality Inputs/Outputs - 12 Outputs, 4 DI on the Basic board - 12 Outputs, 4 DI on the Expansion board Communication Ports: - RS232/485 - RS232 - Radio/Line Power: - 12V DC in - 5, 7.5, 9.5, 12V DC (2Amp) Power out for portable radio 20 LED for Status display 1 Push button (various functions) 12VDC Power In Relay outputs for Solenoids: 24V AC or, External power connection IRRInet-M DC 12VDC Power In DC Latch Solenoids activated by 3300 µF 35 VDC capacitor

4 IRRInet-M – Master/Slave configuration (1)
IRRInet-M supports 3 modes of operations RTU (loaded with IRRI 7.0 Master) Performing all irrigation functions (IRRIV Capabilities) Reporting to the ICC, Via the MDLC Cloud Stand Alone (loaded with IRRI 7.0 Master) Performing all irrigation functions as a stand-alone unit when the system is installed without an ICC Remote I/O (loaded with IRRI 7.0 Slave) Serving as a Distributed I/O for another unit (the Master) Please note! In the PAST whenever using SCORPIO or IRRIcom, it was ALWAYS as a Remote I/O to a Master IRRInet This is NOT a MUST anymore! Use the Slave option only when needed!!

5 IRRInet-M – Master/Slave configuration (2)
MDLC ICC FIU Master Slave Loaded with IRRIV 7.0 Slave Master Master Loaded with IRRIV 7.0 Master Slave

6 IRRInet-M – RS485 Port Options
MDLC D ICC FIU RS485 Master MDLC Connection to ICC Master RS485 A RS485 C Slave RS485 Remote I/O (Slave) to IRRInet-ACE Master B Master Operating Piccolo XR’s Remote I/O (Slave) to IRRInet-M Master Slave PIU

7 IRRInet-M – RS232 Port Options
Pocket PC (ARM) IRRInet-M – RS232 Port Options F MDLC RS232 RS232 E ICC A IRRInet-M FIU RS232 Master MDLC Connection to ICC Master RS232 B RS232 D Slave RS232 Remote I/O (Slave) to IRRInet-ACE Master C Master Operating Piccolo XR’s Remote I/O (Slave) to IRRInet-M Master Slave PIU

8 IRRInet-M – Radio Port Options (it is Radio or Line, Configurable)
Please note! C and D may not co-exist with the same unit MDLC RS232 E ICC A Radio Link, MDLC Cloud IRRInet-M FIU Master Master/Slave Connection to New and/or Old remotes Master B D Slave Remote I/O (Slave) to IRRInet-ACE Master C Legacy Scorpio/IRRIcom Impact Remote I/O (Slave) to IRRInet-M Master Slave You may configure the IRRInet-M To “Talk” PRIS

9 IRRInet-M – Line Port Options (it is Radio or Line, Configurable)
MDLC RS232 C ICC A Line Link, MDLC Cloud IRRInet-M FIU Master Master/Slave Connection to another IRRInet-M Line Line B Master Master to ICC Slave Remote I/O (Slave) to IRRInet-M Master

10 Q: I need to add a new device to a network that already has Scorpio(s) or IRRIcom(s). What do I do? A: Below… FIU MDLC ICC Please note! Load IRRIV Master for direct connection to ICC or, Load IRRIV Slave with PRIS protocol to report to the legacy IRRInet-XL/XM IRRInet XL/XM IRRIcom Scorpio IRRInet-M

11 Q: When should I use IRRInet-M and when should I use IRRInet-ACE
Q: When should I use IRRInet-M and when should I use IRRInet-ACE? A: Below… MDLC ? FIU IRRInet-ACE ICC IRRInet-M This release will deliver the following for the IRRInet-ACE IRRIV 7.X (Master) running on the IRRInet-ACE Usage of current released I/O Modules Support on-site programming, using Pocket PC machine (ARM based) It takes a whole System Planner to explain all considerations: but…) Communication Media larger variety on IRRInet-ACE Line needed? only on IRRInet-M Number of needed Ports (only 3 on IRRInet-M, 5 on IRRInet-ACE I/O specification DC solenoids, only on IRRInet-M Analog I/O only on IRRInet-ACE I/O count Up to 24 Outputs and 8 inputs on IRRInet-M, up to 8 Modules on IRRInet-ACE RUNGS needed? Only on IRRInet-ACE

12 Q: I have an IRRInet XL/XM I need to replace, or add. What do I do
Q: I have an IRRInet XL/XM I need to replace, or add. What do I do? A: Below… FIU MDLC ICC Option B IRRInet-ACE IRRInet XL/XM Master Option A IRRInet-M

13 Q: I need to add IRRInet-ACE, but this unit MUST operate the legacy Scorpio, IRRIcom or Impact. What do I do? A: Below… Please note! The IRRInet-M will route the PRIS commands to the legacy units. It may serve, at the same time, as a slave as well. MDLC FIU ICC IRRInet-ACE RS485 IRRInet XL/XM IRRInet-M Router Slave Scorpio Impact IRRIcom

14 A. Connect IRRInet-M to the IRRInet-ACE to serve as its I/O board
Q: In fact, the IRRInet-ACE does not have dedicated Modules for Irrigation, So…? A: Below… MDLC FIU ICC IRRInet-ACE RS485 IRRInet-M A. Connect IRRInet-M to the IRRInet-ACE to serve as its I/O board (AC and/or DC) B. Use the ACE’s Relay I/O Module for AC solenoids, or any other ACE original I/O Module

15 IRRInet-M AC User’s Connections
1 DO1 DO13 2 DO2 DO14 3 DO3 DO15 4 DO4 DO16 5 DO5 DO17 6 DO6 DO18 7 DO7 DO19 8 DO8 DO20 9 DO9 DO21 10 DO10 DO22 DO11 DO23 DO12 DO24 COM OUT DO WET USER PGND DI1 DI5 DI2 DI6 DI3 DI7 DI4 DI8 DI Please note! The relays may operate the solenoids using external WET Power (programmable). Up to 60 VDC or 30 VAC For Radio Communication For Radio Power: 5, 7.5, 9.5, 12 VDC, 2 Amp Programmable Port 3 for Line Communication 12 V DC (Optional): To operate the Logic Board 1A per output, 6 Amp Total 24 VAC for Logic Board and I/O operation Over Current Detection (10A)

16 IRRInet-M DC User’s Connections
1 DO1 DO13 2 DO2 DO14 3 DO3 DO15 4 DO4 DO16 5 DO5 DO17 6 DO6 DO18 7 COM OUT 8 DO7 DO19 9 DO8 DO20 10 DO9 DO21 DO10 DO22 DO11 DO23 DO12 DO24 USER PGND DI1 DI5 DI2 DI6 DI3 DI7 DI4 DI8 DI Capacitor µF 35 VDC Discharge Voltage – 4 to 35 VDC (Configurable) Pulse Width: up to 120mSec For Radio Communication For Radio Power: 5, 7.5, 9.5, 12 VDC, 2 Amp Programmable Port 3 for Line Communication 12 V DC for Logic board and Solenoids operation Open Loop and Short Detection

17 IRRInet-M – New Front Label
New Design 20 LED's for: (detailed explanation in the Manual) CPU Status I/O Status Error Logger Status

18 IRRInet-M – Push Button
Various Functions Reset (and download SW) Test Scroll Page for LED Display

19 SW Features Capacity User Configuration
IRRInet-M supports 3 modes of operations RTU (loaded with IRRI 7.0 Master) Performing all irrigation functions (IRRIV Capabilities) Reporting to the ICC, Via the MDLC Cloud Stand Alone (loaded with IRRI 7.0 Master) Performing all irrigation functions as a stand-alone unit when the system is installed without an ICC Remote I/O (loaded with IRRI 7.0 Slave) Serving as a Distributed I/O for another unit (the Master) Capacity 250 Outputs 250 Inputs 125 Main Lines 200 Programs 200 Groups 50 Fertilizer Pumps 50 Filter Batteries User Configuration Solenoid Operation Voltage (IRRInet-M DC) Radio Operation Power (AC and DC) External/Internal Relay’s Power Switching (IRRInet-M AC)

20 On-Site Programming SW (Pocket PC Connectivity (ARM Only)
2 Modes of operation: Terminal Stand-Alone On-Site Programming SW (Pocket PC Connectivity (ARM Only) Windows Mobile 5.X compatible Product IRRIcom IRRInet- XM IRRInet-XL IRRInet-M IRRInet-ACE Pocket PC Connection to… NO Running IRRIV 5.X Running IRRIV 7.X (Master only) 7.X (Master) Please note! F4050A – on-site Programming SW, for Pocket PC.

21 Configuration Tool STS STS Software
The new STS (ACE3600 Configuration Tool), will be used to configure the IRRInet-M and the IRRInet-ACE STS Software

22 IRRInet-M Models and Options (1)
Please note! Entering Frequency is Mandatory for models W/Radio IRRInet-M DC F4960A IRRInet-M DC no Radio F4964A IRRInet-M DC with UHF Portable Radio F4963A IRRInet-M DC with VHF Portable Radio IRRInet-M AC F4860A IRRInet-M AC no Radio F4864A IRRInet-M AC with UHF portable Radio F4863A IRRInet-M AC with VHF Portable Radio

23 IRRInet-M Models and Options (2)
For VHF Radio V951AM VHF Radio for N.A (HT750) For UHF Radio V951AN UHF Radio for N.A (HT750) Please note! The AC Expansion fits both the IRRInet-M AC and DC main boards V314AR Add DC 4/12 I/O Expansion V803 Load IRRIV 7.0 Master Application V260AM Add AC 4/12 I/O Expansion V804 Load IRRIV 7.0 Slave Application V020AC DIN Rail Installation Kit

24 IRRInet-ACE Models and Options
For IRRInet-ACE use ACE3600 catalog pages, and… V450 to order IRRInet-ACE 3610 CPU (this CPU is identified with the Irrigation) V451 to order IRRInet-ACE 3640 CPU (this CPU is identified with the Irrigation) V805 ask factory to load IRRIV 7.X application (Master) into the CPU

25 New deliverables summary
IRRInet-M IRRInet-M AC IRRInet-M DC IRRInet-M AC Expansion Board IRRInet-M DC Expansion Board IRRIV 7.X for IRRInet-M Master IRRIV 7.X for IRRInet-M Slave IRRInet-ACE IRRIV 7.X for IRRInet-ACE Master STS – New version supporting Irrigation ICC – New version 14.X (supporting new deliverables) On-Site Programming SW (for Pocket PC)

26 END Thank YOU!


Download ppt "IRRInet-M IRRInet-ACE Product Introduction"

Similar presentations


Ads by Google