1 Survey of power system transient stability event
-- Brazilian Blackout 2009 Christine Garcia1 , Blair Johnson1 , Dr. Jing Wang2 Lenoir City High School 1 , West High School 1, Xinjiang University2 Introduction In November of 2009, Itaipu Dam was shut down in Brazil because of an instability problem. Shutting the dam down caused a massive blackout that not only affected 18 out of Brazil’s 26 states, but its neighboring country Paraguay as well. There were many factors put into play to encourage this blackout to occur. Power System Model PT (Constant) Objectives Understanding the cause of the blackout as well as the way the power system is built. Modeling the fault occurring on the system using Matlab/Simulink. Understanding the different parameters within the power system that could have been altered to prevent the power outage. Electrical Power Pe Load Angle δ0 Stable Situation Methods The first step in this process was to model the Itaipu Dam, its transformers, transmission lines, and the rest of the Brazilian grid. We first ran a reference test to determine the power output and load angle of the system under normal conditions. The next test was to determine what would have happened, had the breakers on the transmission lines opened quickly enough. The final test was to model the fault as it actually happened, in which the ageing breakers opened opened too slowly to prevent massive instability. Electrical Power Pe Load Angle δ0 Breaker time at 0.07s Electrical Power Pe Load Angle δ0 Breaker time at 0.21s Analysis Load angle refers to the lag (in degrees) between the rotating magnetic field, and the magnetic field of the stator. Too much variation in this angle causes instability in the generator. When comparing the control test to the test with correct timings, the control is very stable and has very little variation after the initial surge. In contrast, the system that did not suffer from slow breakers experienced instability at the beginning, but stabilized as time went on. The system representative of the actual blackout experienced sporadic instability at the time of the fault and continued to show instability throughout the simulation. Conclusions The data suggests that the massive fluctuations in power and load angle at the time of the blackout could have been controlled by faster breakers. Load Angle δ ω PT Pe ωN δ0 SPONSORS: “This work was supported in part by the Engineering Research Center Program of the National Science Foundation and the Department of Energy under NSF Award Number EEC and the CURENT Industry Partnership Program. "


Download ppt "Survey of power system transient stability event"

Similar presentations


Ads by Google