Presentation is loading. Please wait.

Presentation is loading. Please wait.

Dr Anthony Williams A&B Mylec Dr Oliver Scholes Vale International SA

Similar presentations


Presentation on theme: "Dr Anthony Williams A&B Mylec Dr Oliver Scholes Vale International SA"— Presentation transcript:

1 Effect of Blending on Operational Performance and Generation Costs of an Indian Power Plant
Dr Anthony Williams A&B Mylec Dr Oliver Scholes Vale International SA 1st IEA CCC Coal Quality Workshop 9-10 November 2016 New Delhi India

2 Background – Moatize Mine
Vale’s Moatize mine produces a hard coking coal product and a thermal coal product. Mine is ramping up to an output of 22mt of coal per year. Coal Quality Calorific Value – 6050 kcal/kg GAR Moisture - 5% AR Ash – 24% AR Volatile Matter – 20 % AD HGI – 72 IDT AFT – 1480 oC (red)

3 India – Coal Fired Power Plants
Very high coal production & coal fired power capacity Numerous coal mines with large rail network Railways

4 Mundra Power Plant - Coal Supply Options
5x800MW Supercritical Design on Indo/SA blend Indo coal contract 1 coal in blend is fixed

5 Coal Quality Increasing Energy

6 Blend Modelling – MarketMastor™
Domestic freight+Port+Taxes Shipping+Port Scenarios Power Plant Model Market Model Power Plants Specs Evaluate Output Coals Coal Quality Mines Blending Trade

7 Plant Limitations – Studied coals
Moatize Raw Coals

8 Binary and Ternary Blends

9 Ternary Blends

10 All Blends Accepted Blends Low No. of blends High No. of blends
Ternary Blends All Blends Accepted Blends Low No. of blends High No. of blends

11 Pulveriser Performance
Top 50 Blends Accepted Blends All Blends

12 Top 50 Blends Accepted Blends All Blends
Mill Erosion Top 50 Blends Accepted Blends All Blends

13 Top 50 Blends Accepted Blends All Blends
Boiler Efficiency Top 50 Blends Accepted Blends All Blends

14 Combustion performance
Top 50 Blends Accepted Blends All Blends

15 Top 50 Blends Accepted Blends All Blends
Carbon-in-ash Top 50 Blends Accepted Blends All Blends

16 Top 50 Blends Accepted Blends All Blends
Dust Emissions Top 50 Blends Accepted Blends All Blends

17 Top 50 Blends Accepted Blends All Blends
SO2 Emissions Top 50 Blends Accepted Blends All Blends

18 Top 50 Blends Accepted Blends All Blends
Auxiliary Power Top 50 Blends Accepted Blends All Blends

19 Operating and Maintenance Costs
Top 50 Blends Accepted Blends All Blends

20 Top 50 Blends Accepted Blends All Blends
Total Generation Cost Top 50 Blends Accepted Blends All Blends

21 Electrical Output (GWh/a)
Top 50 Blends Accepted Blends All Blends

22 Best Blends Generation Costs (US$/MWhr) BEST BEST BLENDS BLENDS
Sent out Energy (GWhr/a)

23 POWER PLANT PERSPECTIVE
Power plant confirmed a close match between the actual power plant performance and the desktop analysis. Agreed with the technical recommendation of using Moatize coal in 20% blend where possible. Ash deposition potential of currently used coal reduces by 20% when using Moatize coal. Blend usage has resulted in higher boiler efficiency, improved mill performance, reduction in mill power, and reduction in power for draft system (reduction in auxiliary power use). Mundra power plant are continuing to use Moatize coal

24 CONCLUSIONS A different point of view is required when evaluating coals for blending Negative attributes can be smoothed over by blending Large number of possible blends can be evaluated Blending can improve plant performance and reduce fuel costs Beneficial in applying plant limitations to blend coal quality specs, not on raw coals Moatize coal was determined to blend very favourably with the existing coal used at Mundra Power Plant Moatize coal blended better than other coals Limit to how much can be added but evaluations and plant trials showed coal can be considered as an excellent blending coal Power plant trials determined Moatize coal improved plant performance and decreased costs

25 ACKNOWLEDGEMENTS Thanks to A&B Mylec for providing permission to prepare and present at the IEA CCC workshop Thanks to Vale for sponsoring the trip costs for the workshop