Reactor Experiments Instructor: Prof. Kune Y. Suh T/A : Sang Hyuk Yoon

Similar presentations


Presentation on theme: "Reactor Experiments Instructor: Prof. Kune Y. Suh T/A : Sang Hyuk Yoon"— Presentation transcript:

1 Reactor Experiments Instructor: Prof. Kune Y. Suh T/A : Sang Hyuk Yoon
Saturday, June 14, 2003 Composer : Team F

2 Contents Members and Malfunction Nuclear Power Plant System
Drop of All Control Rod in CBA Turbine Trip FW Pump

3 Members of Team F Members of Team F Jeong, Won Chae Kim, Chan Soo
Choi, Sang Gook Kim, Chan Soo Mun, Seung Hyeon Yoon, Ei Sung Lee, Yoon Jeong

4 Malfunction Choi, Sang Gook & Lee, Yoon Jeong
A-1 Drop of All Control Rods in CBA Choi, Sang Gook & Lee, Yoon Jeong J-55 Turbind Trip Jeong, Won Chae & Yoon, Ei Sung L-67 FW Pump Trip Kim, Chan Soo & Mun Seung Hyeon

5 Power Plant System

6 Control Rod Choi, Sang gook Lee, Yoon Jeong

7 Control Rod Grid of the Control Rod GSSS

8 Control Rod control element drive mechanism CEA

9 Control Rod Methods to Control the Activity in Core
Dilusion by Chemical and Volume Control System Boric acid is dissloved But the reaction is slow Using the Control Rods

10 Control Rod Function To control the reactivity of the core by quick putting and pulling out the control rod To solve the weak points of CVCS dilusion method

11 Control Rod Composition Totally 81 rods Shut Down group A,B
Regulating Control group Part Strength Control group Control Element Drive Mechanism – Magnetic Forced Mechanism

12 Control Rod Composition Material of the toxic substance in rod
- B4C Material of the cladding - Ni-Cr-Fe 652

13 Control Rod Control Rods Accidents 1. Ejection of the control rods
Disorder of rod control equipment Mistake of operator Reactivity of the core increases Generation of Serious peak power Fuel damage, Trip

14 Control Rod Control Rod accident 2. Drop of all control rods in CBA
Breaken equipment Interception of electricity Reactivity decreases Power generation decreases Pressure, Temperature, DNBR changes

15 Control Rod Net reactivity

16 Control Rod Average temperature of Primary loop

17 Control Rod Core coolant temperature

18 Control Rod Pressurizer pressure

19 Control Rod Steam generator Pressure

20 Control Rod DNBR

21 Control Rod Conclusion Drop of all control rods in CBA
Output of whole core power decreases average temperature decreases reactivity increases(feedback effect) the reason of reactivity, DNBR movement According time goes, temperature and pressure decrease. The accident stops.

22 Turbine Jeong, Won Chae Yoon, Ei Sung

23 Turbine Function To convert the steam which is made in the steam generator to energy When the steam expands through the nozzle and blades of a turbine to a condenser, it rotates the rotor of the turbine blades, which links to the axis of the generator

24 Turbine Scene of Turbine Building inside

25 Turbine Scene of Turbine Building inside

26 Turbine Turbine

27 The system of the LP Turbine

28 The system of the HP Turbine

29 Turbine Causes of Turbine Trip Overload (Overspeed)
Wearing the bearing Solenoid trip Low pressure of condenser The manual trip of turbine

30 Turbine Effects of the Turbine Trip Turbine Trip Steam dumped by ETS
Pressure reduction The boiling point of the feed water is decreased The heat removed through the steam generator is decreased

31 Turbine Effects of the Turbine Trip
The temperature of reactor coolant increase The reactivity of core decrease The sweeling of the water level in the Reactor DNB Melting down of core <<Serious Accident!!!>>

32 Turbine ETS (Emergecy Trip System)
Interrupting the supply of steam and discharging it if turbine is tripped Functioning in mechanical or by the electrical signal from the detector

33 Turbine Anticipation Primary Loop Secondary Loop Temperature Increase
Decrease Pressure

34 Temp. & Press. Incease in Steam Line
Turbine Results Turbine Trip Turbine Load = 0 2nd Loop Flow Rate Dec. Feed Water Temp. Dec. Reaction for SAFE Heat Exchange Rate Dec. Water Level Dec. Pressure Inc. S/G Heat Transf. Rate Inc. Temp. & Press. Incease in Steam Line

35 Turbine Results Turbine Trip Turbine Load = 0

36 Turbine Results 2nd Loop Flow Rate Dec. Turbine Trip

37 Turbine Results Temp. of FW S/G Level S/G Prssure 2nd Loop Flow
Rate Dec. Heat Exchange Rate Dec. Water Level Dec. Pressure Inc. S/G Feed Water Temp. Dec. Temp. of FW S/G Level S/G Prssure

38 Temp. & Press. Incease in Steam Line Steam Presssure from S/G
Turbine Results Heat Exchange Rate Dec. Water Level Dec. Pressure Inc. S/G Temp. & Press. Incease in Steam Line Steam Presssure from S/G

39 Turbine Results Turbine Trip Cold Leg Temp. Inc. Reactivity Dec.
2nd Loop Flow Rate Dec. DNBR > 1.3 Heat Exchange Rate Dec. Water Level Dec. Pressure Inc. S/G Power Dec. SAFE Hot Leg Temp. Dec. Avg. Temp. Dec.

40 Turbine Results Cold Leg Temp. Reactivity Heat Exchange Rate Dec.
Water Level Dec. Pressure Inc. S/G Cold Leg Temp. Inc. Reactivity Dec. Cold Leg Temp. Reactivity

41 Turbine Results Reactivity Dec. Power Dec. DNBR > 1.3 SAFE
Relative Power DNBR

42 Turbine Results Avg. Temp. Dec. Hot Leg Temp. Dec. Power Dec.
Avg. Temp. of Core

43 Feedwater Pump Kim, Chan Soo Mun, Seung Hyeon

44 Feedwater Pump Function
Main feedwater system sends water to each steam generator(SG) Main feedwater pump circulates secondary water

45 Feedwater Pump

46 Feedwater Pump

47 Feedwater Pump

48 Feedwater Pump Scram of Indiviual Main Feedwater Pump
1. Lubricating Oil Low Pressure(0.62kg/cm2) 2. Turbine Overspeed(~4928RPM) 3. Condenser Low Vacuum Level(480.6mmHg) 4. Impellent Force Bearing Excess Abrasion 5. Low Inspiration Pressure(Lo-NPSH)(15.5kg/cm2)

49 Feedwater Pump Emegency Stop of All Main FW Pump
1. Safety Injection Signal 2. SG High Level 3. All condenser Pump Trip 4. Pump Release Header High Pressure

50 Feedwater Pump Identification of event and causes
The loss of normal flow(LFW) event may be initiated by losing main feedwater pumps

51 Feedwater Pump Sequence of event and system Operation
Decreasing water level and increasing pressure and temperature in the steam generator The RCS pressure and temperature rise. Reactor trip

52 Feedwater Pump Emergency Measure of the Accident
Termination of main steam flow SG and Reactor Coolant System(RCS) pressurization Decrease in core heat rate

53 Feedwater Pump RCS becomes New Steady-state Condition
Auxiliary feedwater Injection Cooldown by Operator

54 Feedwater Pump Analysis of Effects and Consequences
Maximum RCS pressure and fuel integraty for the LFW is less than that for the loss of condenser vacuum event(LOCV) The initial Departure from nucleate boiling rate (DNBR) is the minimum DNBR The minimum DNBR remains above 1.30.

55 Feedwater Pump Conclusion
The RCS pressure remains below 19.5MPa and the SG pressure remains below 9.6MPa Thus, ensuring fuel cladding and secondary system integraty [Assumtion] The only one pump would die.

56 Feedwater Pump S/G Generator #1

57 Feedwater Pump S/G Generator #2

58 Feedwater Pump S/G Generator #3

59 Feedwater Pump Average Temp. #1

60 Feedwater Pump Average Temp. #2

61 Feedwater Pump S/G Level Error Signal

62 Feedwater Pump DNBR