Presentation is loading. Please wait.

Presentation is loading. Please wait.

For system diagrams and component identification

Similar presentations


Presentation on theme: "For system diagrams and component identification"ā€” Presentation transcript:

1 For system diagrams and component identification
Pneumatic Symbols For system diagrams and component identification

2 Contents Standards Actuators Basic symbols Valve symbol structure
Functional elements Valve functions Flowlines Three position valves Connections Operators Conditioners and plant Port marking Pressure regulators Function components Relief valves Symbol Library Click the section to advance directly to it

3 Graphic Symbols Standards
Pneumatic symbols conform to and are devised from the International Standard ISO This covers graphical symbols for Fluid Power Systems and Components Port markings for fluid power valves are not covered by the ISO standard. These are taken from the recommendations of CETOP RP 68 P 2

4 Basic Symbols

5 Shapes These shapes and lines in the relative proportions shown, make up a set of basic symbols from which fluid power symbols and circuits are constructed

6 Basic Symbols (shapes)
Symbol sets can be drawn to any size but their scale and relative proportions are determined by a basic dimension of your choice ā€œlā€ Circles l energy conversion units 3/4 measuring instrument 1/3 mechanical link roller 10

7 Basic Symbols (shapes)
Square at 45o conditioning apparatus connections to corners Square control component connections perpendicular to sides Rectangle cylinders and valves l > l

8 Basic Symbols (shapes)
certain control methods, length between limits to suit Rectangles cushion continued piston max 2 l min 1 l 1/2 l l 1/4 l

9 Basic Symbols Semi-circle Capsule Double line l
rotary actuator, motor or pump with limited angle of rotation Semi-circle mechanical connection piston rod, lever, shaft Double line Capsule pressurised reservoir air receiver, auxiliary gas bottle l 1/5 l 2 l 13

10 Basic Symbols Line Dashed Chain Working line, pilot supply,
return, electrical Chain Enclosure of two or more functions in one unit Dashed Pilot control, bleed, filter Electrical line 1 2 3 12 10 14

11

12 Functional Elements

13 Functional Elements Triangle Spring Arrow
Long sloping indicates adjustability Arrow 1/3 l size to suit Spring Triangle Direction and nature of fluid, open pneumatic or filled hydraulic 1/4 l 1/2 l 15

14 Functional Elements Arrows Tee Restriction Straight or sloping
path and flow direction, or motion Arrows Size to suit Restriction Tee Closed path or port 15

15 Functional Elements Curved arrows Shaft rotation Seating rotary motion
90o angle Seating rotary motion Curved arrows clockwise from right hand end Shaft rotation anti-clockwise from right hand end both 16

16 Functional Elements Temperature Operator Prime mover
Indication or control size to suit Temperature Operator Opposed solenoid windings Prime mover M Electric motor 16

17 Flowlines and Connections

18 Flowlines Junction Crossing Flexible line Single Four way junction
not connected Crossing Junction Single Hose usually connecting parts with relative movement Flexible line Four way junction 17

19 Connections Air bleed Air exhaust Continuous Temporary by probe
No means of connection Temporary by probe With means of connection

20 Connections Coupling quick release Coupling quick release self sealing
Both to exhaust Coupling quick release Coupling quick release self sealing Source sealed Both sealed

21 Connections Rotary connection one line Rotary connection two lines
Rotary connection three lines

22 Conditioners and Pressure
Producing Plant

23 Conditioners Water separator with manual drain
Water separator with automatic drain Filter with manual drain Filter with automatic drain Lubricator Water separator with manual drain

24 Conditioners Dryer Cooler with and without coolant flow lines Heater
Combined heater / cooler

25 Plant Compressor and electric motor Air receiver Isolating valve
Air inlet filter M Compressor and electric motor

26 Pressure Control

27 Pressure regulators A pressure regulator symbol represents a normal state with the spring holding the regulator valve open to connect the supply to the outlet. The dotted line represents the feedback, this opposes the spring and can vary the flow through the valve from full flow, through shut off, to exhaust. The symbol is usually drawn in only this one state. The flow path can be imagined to hinge at the right hand end to first shut off the supply then connect to the exhaust. Adjustable Regulator simplified Adjustable Regulator with pressure gauge simplified

28 Filter Regulator Lubricator
FRL Combined unit FRL Simplified symbol

29 Pressure relief valves
A pressure relief valve symbol represents a normal state with the spring holding the valve closed. The dotted line represents feed-forward, this opposes the spring and can be imagined to lift the flow path. When the pressure reaches an excess value the flow path will line up with the ports and flow air to relief. Adjustable relief valve simplified Preset relief valve simplified

30

31 Actuators

32 Actuators Cylinders symbols can be any length over ā€œlā€
The piston and rod can be shown in the retracted, extended or any intermediate position ā€œlā€

33 Single acting Single acting sprung instroked
Single acting sprung outstroked Single acting sprung instroked magnetic * Single acting sprung outstroked magnetic * * ISO provides no example for magnetic cylinders

34 Single acting without spring
Single acting normally instroked external force returns Single acting normally outstroked external force returns Single acting normally instroked magnetic external force returns Single acting normally outstroked magnetic external force returns Note: the hardware is usually double acting cylinders applied as single acting

35 Double acting * Double acting adjustable cushions
Double acting through rod Double acting magnetic * Double acting rodless * * ISO provides no example for magnetic or rodless cylinders

36 Rotary actuators Semi rotary double acting
Rotary motor single direction of rotation Rotary motor bi-directional

37 Simplified cylinder symbols
Single acting load returns Single acting spring returns Double acting non cushioned Double acting adjustable cushions Double acting through rod

38

39 Valve symbol structure

40 Valve symbol structure
The function of a valve is given by a pair of numerals separated by a stroke, e.g. 3/2.. The first numeral indicates the number of main ports. These are inlets, outlets and exhausts but excludes signal ports and external pilot feeds. The second numeral indicates the number of states the valve can achieve.

41 Valve symbol structure
A 3/2 valve therefore has 3 ports (normally these are inlet, outlet and exhaust) and 2 states (the normal state and the operated state) The boxes are two pictures of the same valve operated normal

42 Valve symbol structure
A valve symbol shows the pictures for each of the valve states joined end to end operated normal

43 Valve symbol structure
A valve symbol shows the pictures for each of the valve states joined end to end operated normal

44 Valve symbol structure
The port connections are shown to only one of the diagrams to indicate the prevailing state normal

45 Valve symbol structure
The operator for a particular state is illustrated against that state Operated state produced by pushing a button

46 Valve symbol structure
The operator for a particular state is illustrated against that state Operated state produced by pushing a button Normal state produced by a spring

47 Valve symbol structure
The operator for a particular state is illustrated against that state Operated state produced by pushing a button Normal state produced by a spring

48 Valve symbol structure
The valve symbol can be visualised as moving to align one state or another with the port connections

49 Valve symbol structure
The valve symbol can be visualised as moving to align one state or another with the port connections

50 Valve symbol structure
The valve symbol can be visualised as moving to align one state or another with the port connections

51 Valve symbol structure
A 5/2 valve symbol is constructed in a similar way. A picture of the valve flow paths for each of the two states is shown by the two boxes. The 5 ports are normally an inlet, 2 outlets and 2 exhausts

52 Valve symbol structure
The full symbol is then made by joining the two boxes and adding operators. The connections are shown against only the prevailing state

53 Valve symbol structure
The full symbol is then made by joining the two boxes and adding operators. The connections are shown against only the prevailing state

54 Valve symbol structure
The full symbol is then made by joining the two boxes and adding operators. The connections are shown against only the prevailing state

55 Valve symbol structure
The recommended spacing of the connections 1/4 l 1/2 l

56 Valve symbol structure
The boxes can be joined at either end but the operator must be drawn against the state that it produces. The boxes can also be flipped A variety of symbol patterns are possible normally closed normally open

57 Valve symbol structure
The boxes can be joined at either end but the operator must be drawn against the state that it produces. The boxes can also be flipped A variety of symbol patterns can be produced Reverse connected

58 Valve functions

59 Valve functions Basic valves before operators are added
Examples, push button operated with spring return Normal position Function 2/2 Function 3/2 25

60 Valve functions Basic valves before operators are added
Examples, push button operated with spring return Operated position Function 2/2 Function 3/2 25

61 Valve functions Basic valves before operators are added
Examples, push button operated with spring return Normal position Function 4/2 Function 5/2 26

62 Valve functions Basic valves before operators are added
Examples, push button operated with spring return Operated position Function 4/2 Function 5/2 26

63 Valve functions 5/3 Three position valves have a normal central position that is set by springs or with a manual control such as a lever The flow pattern in the centre position varies with the type. Three types will be considered 1, All ports sealed 2, Outlets to exhaust, supply sealed 3, Supply to both outlets, exhausts sealed

64 Valves 5/3 All valves types shown in the normal position
Type 1. All ports sealed Type 2. Outlets to exhaust Type 3. Supply to outlets

65 Valves 5/3 All valves types shown in the first operated position
Type 1. All ports sealed Type 2. Outlets to exhaust Type 3. Supply to outlets

66 Valves 5/3 All valves types shown in the normal position
Type 1. All ports sealed Type 2. Outlets to exhaust Type 3. Supply to outlets

67 Valves 5/3 All valves types shown in the second operated position
Type 1. All ports sealed Type 2. Outlets to exhaust Type 3. Supply to outlets

68 Valves 5/3 All valves types shown in the normal position
Type 1. All ports sealed Type 2. Outlets to exhaust Type 3. Supply to outlets

69 Operators

70 Operators Manual General manual Lever Push button Pedal Pull button
Treadle Push/pull button Rotary knob 27

71 Operators Mechanical Plunger Pressure Spring normally as a return
Pilot pressure Roller Differential pressure Uni-direction or one way trip Detent in 3 positions 27

72 Operators Electrical Solenoid direct Solenoid pilot
with manual override and external pilot supply Solenoid pilot When no integral or external pilot supply is shown it is assumed to be integral Solenoid pilot with manual override and integral pilot supply 27

73 Port markings

74 Port Markings To CETOP RP68P 2 1 2 3 12 10 12 10 1 2 4 4 2 14 12 14 12
5 3 29

75 Port Markings To CETOP RP68P 2 2 12 10 12 10 1 3 1 2 4 4 2 14 12 14 12
5 3 29

76 Port Markings To CETOP RP68P 2 1 2 3 12 10 12 10 1 2 4 4 2 14 12 14 12
5 3 29

77 Port Markings To CETOP RP68P 2 1 2 3 12 10 12 10 1 2 4 4 2 14 12 14 12
5 3 29

78 Port Markings To CETOP RP68P 2 1 2 3 12 10 12 10 1 2 4 4 2 14 12 14 12
5 3 29

79 Function components

80 Function components Non-return valve simplified
Flow regulator uni-directional Flow regulator bi-directional simplified Two pressure ā€˜ANDā€™ simplified Note: The output can exhaust back and is not trapped Shuttle valve ā€˜ORā€™ simplified

81 Function components Quick exhaust valve with silencer simplified
Pressure to electric switch preset Pressure to electric switch adjustable

82 Symbol Library Actuators Function Components Solenoid Valves Vacuum
Electrical and electronic Air Line Click the section arrow to go to it

83 Symbol Library Actuators

84 Single acting cylinders
Magnetic sprung in non-rotating rod Sprung in Sprung out Magnetic sprung out non-rotating rod Magnetic sprung in Magnetic sprung out

85 Single acting cylinders
Sprung in adjustable cushion Sprung out adjustable cushion Magnetic sprung in adjustable cushion Magnetic sprung out adjustable cushion

86 Single acting cylinders
Sprung in adjustable cushion non-rotating rod Sprung out adjustable cushion non-rotating rod Magnetic sprung in adjustable cushion non-rotating rod Magnetic sprung out adjustable cushion non-rotating rod

87 Single acting bellows Bellows single convolution
Bellows double convolution Bellows triple convolution

88 Double acting cylinders
Non-magnetic Magnetic hydraulic Non-magnetic adjustable cushioned Magnetic adjustable cushioned Non-magnetic rod bellows Magnetic adjustable cushioned rod bellows Magnetic

89 Double acting cylinders
Non-rotating rod Magnetic non-rotating rod Active brake Magnetic active brake Passive brake Magnetic passive brake Guided rod magnetic

90 Double acting cylinders
Non-magnetic through rod Non-magnetic adjustable cushioned through rod Magnetic through rod Magnetic adjustable cushioned through rod

91 Double acting cylinders
Three position adjustable cushions (equal strokes) Three position adjustable cushions magnetic (equal strokes) Four position adjustable cushions (unequal strokes) Four position adjustable cushions magnetic (unequal strokes)

92 Other actuators With electronic analogue output of piston position
Slide unit Semi-rotary actuator Rotary motor bi-directional and non-reversible

93 Rodless cylinders Cushioned Cushioned magnetic Cushioned passive brake
Cushioned magnetic passive brake Cushioned active brake Cushioned magnetic active brake

94 Rodless cylinders Twin stroke cushioned
Twin stroke air through carriage Twin stroke cushioned magnetic Twin stroke air through carriage magnetic

95 Shock absorbers Self adjusting Adjustable

96 End

97 Symbol Library Air Line Equipment

98 Combination units FRL with shut off valve and pressure gauge
Lubro-control unit Filter and lubricator

99 Combination units Breathing air set Filter regulator
Filter regulator with gauge

100 Filters Filter with manual drain Filter with automatic drain
Filter with automatic drain and pressure drop indicator

101 Pressure regulators Pre-set relieving
Pre-set relieving with pressure gauge Adjustable relieving Adjustable relieving with pressure gauge

102 Pressure regulators Pilot operated
Pilot regulator with independent feedback Pilot operated regulator controlled from pilot regulator

103 Pressure regulators Precision dual stage (11-818)
2 3 Proportional pressure valve

104 Lubricator Lubricator

105 Pressure relief valves
Preset, no means of connection to exhaust Preset, tapped exhaust port Adjustable, no means of connection to exhaust Adjustable, tapped exhaust port Pilot operated

106 Other components Silencer Filter silencer
Water separator automatic drain

107 End

108 Electrical and Electronic
Symbol Library Electrical and Electronic

109 Sensors Reed switch 2 wire Reed switch changeover
Loads must be additionally suppressed brown +V Load blue 0V Reed switch 2 wire brown +V blue black 0V Load Reed switch changeover Reed switch 3 wire with led indicator (emulating current sourcing pnp device) brown +V blue 0V Load 0V black brown +V blue 0V Load +V black Reed switch 3 wire with led indicator (emulating current sinking npn device) brown +V blue Load 0V Reed switch 2 wire with led indicator

110 Sensors Solid state magnetic sensor pnp (current sourcing)
Loads must be additionally suppressed brown +V blue 0V black pnp Load 0V Solid state magnetic sensor pnp (current sourcing) 1 3 4 pnp brown +V blue 0V black Load 0V Solid state magnetic sensor plug in cable pnp (current sourcing) Solid state magnetic sensor npn (current sinking) brown +V black npn Load +V blue 0V 1 Solid state magnetic sensor plug in cable npn (current sinking) 3 4 npn brown +V black Load +V blue 0V Solid state magnetic sensor with pulse extension brown +V blue 0V black Load 0V

111 Sensors Reed switch 2 wire with led indicator and plug in cable
Loads must be additionally suppressed 1 brown +V 4 black Load 0V Reed switch 2 wire with led indicator and plug in cable Reed switch 2 wire with led indicator and plug in cable 1 + brown blue Load 0V

112 Electrical Symbols

113 Electrical symbols Direct current ( DC ) Line to earth
Alternating current ( AC ) Line to chassis AC or DC Cell 12 V or Positive and negative polarity Battery

114 Electrical Components
Normally open closed Normally open closed Relay contact General manual switch contact Push button contact Roller switch contact Pull button contact Delay to operate Twist switch contact Delay to reset

115 Electrical Components
Relay coil Relay coil delay to operate contacts Relay coil delay to reset contacts Solenoid valve coil

116 Electrical Components
Proximity switch Bell Touch sensitive switch Buzzer P Pressure switch Microphone 24V 0V Loudspeaker Supply and return

117 Electronic Component Symbols

118 Electronic Components
Windings inductor inductor with core variable inductor transformer Opto-isolator Resistors Resistor Variable Potentiometer Pre-set pot Voltage dependent Light dependent V or Capacitors capacitor polarised capacitor variable capacitor pre-set capacitor Diodes diode zener diode light emitting diode

119 Electronic Components
Fuse Thyristor Triac Wires connected or NPN Transistor Wires crossing PNP Transistor Double junction or Photo-transistor

120 Electronic Components
Motors dc & ac M M Conductors in a cable Conductors twisted Generator G Plug and socket Lamp steady & flashing Coaxial plug and socket Operational amplifier A W V Meters for amps, volts, ohms & watts

121 End

122 Function Fittings and Components
Symbol Library Function Fittings and Components

123 Function fittings Blocking fitting Pressure reducing fitting
1 2 12 Blocking fitting 1 2 Pressure reducing fitting 1 2 Pneumatic sensor fitting

124 Function components Air fuse Non return valve Non return valve

125 Function components bi-directional flow regulator
Exhaust flow regulator with and without silencer Silencers Shuttle valve ā€˜ORā€™ Two pressure valve ā€˜ANDā€™ (will exhaust either signal back)

126 Function components Uni-directional flow regulator
Quick exhaust valve with and without silencer Rotating joint Pressure indicator Pressure drop indicator

127 Quick release couplings
made released Both to exhaust Source sealed Both sealed

128 End

129 Symbol Library Solenoid Valves

130 Solenoid valves Direct solenoid actuated spring return 2/2 NC
with man override on the solenoid 2 10 12 12 2 10 Direct solenoid actuated spring return 2/2 NC 1 3 12 10 2 2 10 12 1 3 Direct solenoid actuated spring return 3/2 NC 1 2 3 12 10 1 2 3 10 12 Direct solenoid actuated spring return 3/2 NO

131 Solenoid valves Pilot solenoid actuated spring return 3/2 NC
with man override on the solenoid 1 2 3 12 10 1 2 3 12 10 Pilot solenoid actuated spring return 3/2 NC 1 2 3 12 10 1 2 3 12 10 Pilot solenoid actuated spring return 3/2 NO 1 2 3 12 10 1 2 3 10 12 Pilot solenoid actuated pilot solenoid return

132 Solenoid valves Pilot solenoid actuated spring return, 5/2
1 2 4 5 3 14 12 Pilot solenoid actuated spring return, 5/2 1 2 4 5 3 14 12 Pilot solenoid actuated spring return and manual override, 5/2 1 2 4 5 3 14 12 Pilot solenoid actuated pilot solenoid return, 5/2 1 2 4 5 3 14 12 Pilot solenoid actuated pilot solenoid return and manual override, 5/2

133 Solenoid valves Pilot solenoid actuated spring return, 5/2
Reverse piped 4 2 1 5 3 14 12 Pilot solenoid actuated spring return, 5/2 1 2 4 5 3 14 12 Pilot solenoid actuated spring return and manual override, 5/2 1 2 4 5 3 14 12 Pilot solenoid actuated and returned, 5/2 4 2 1 5 3 14 12 Pilot solenoid actuated and returned with manual overrides, 5/2

134 Solenoid valves 1 2 4 5 3 14 12 Double pilot solenoid actuated spring to centre all ports sealed reverse piped Priority pilot solenoid actuated differential air return, 3/2 1 2 3 10 12 1 2 4 5 3 14 12 Priority pilot solenoid actuated differential air return, 5/2

135 Solenoid valves Priority pilot solenoid actuated differential air return, 3/2 1 2 3 10 12 1 2 4 5 3 14 12 Priority pilot solenoid actuated differential air return, 5/2 Priority pilot solenoid actuated air spring return, 3/2 1 2 3 10 12 2 4 1 5 3 14 12 Priority pilot solenoid actuated air spring return, 5/2

136 Solenoid valves 1 2 4 5 3 14 12 Pilot solenoid actuated spring return, manual override, 5/2 with integral flow regulators 1 2 4 5 3 14 12 Double pilot solenoid actuated, manual override, 5/2 with integral flow regulators

137 Solenoid valves 1 2 4 5 3 14 12 Double pilot solenoid actuated, spring to centre all ports sealed, 5/3 with integral flow regulators 1 2 4 5 3 14 12 Double pilot solenoid actuated, spring to centre supply port sealed, 5/3 with integral flow regulators 1 2 4 5 3 14 12 Double pilot solenoid actuated, spring to centre supply to outlets, 5/3 with integral flow regulators

138 Proportional solenoid valves
2 4 1 5 3 Proportional flow to electrical signal 1 2 3 Proportional pressure to electrical signal

139 Safety related valves Monitored dump valve Soft start valve 1 2 3 10
12 Monitored dump valve Soft start valve 1 2 3 12 10

140 End

141 Symbol Library Valves

142 Valves un-tapped exhaust
2 12 10 3 1 Plunger actuated spring return 3/2 Roller actuated spring return 3/2 2 12 10 3 1 Push button actuated spring return 3/2 1 2 3 12 10 Toggle actuated detented 3/2 2 12 10 3 1 Rotary knob actuated detented 3/2 2 12 10 3 1 2 Key actuated detented 3/2 12 10 3 1

143 Valves integral bleed supply
2 12 10 1 3 Plunger / bleed actuated air return 3/2 Roller / bleed actuated air return 3/2 2 12 10 1 3 One way trip / bleed actuated air return 3/2 2 12 10 1 3 Low pressure / bleed actuated air return 3/2 2 12 10 1 3 Antenna / bleed actuated air return 3/2 2 12 10 1 3

144 Valves external bleed supply
2 12 10 3 1 Plunger / bleed actuated air return 3/2 Roller / bleed actuated air return 3/2 12 10 3 1 2 One way trip / bleed actuated air return 3/2 2 12 10 3 1 Low pressure / bleed actuated air return 3/2 12 10 3 1 2 Antenna / bleed actuated air return 3/2 2 12 10 3 1

145 Pilot actuated valves Pilot actuated spring return 2/2 NC NO
12 2 12 10 10 1 1 Pilot actuated spring return 2/2 Pilot actuated spring return 3/2 2 2 12 10 12 10 3 1 3 1 Double pilot actuated 3/2 2 2 12 10 12 10 3 1 3 1 Differential pilot actuated 3/2 1 2 3 12 10 2 12 10 3 1

146 Pilot actuated valves NC NO 1 2 3 12 10 2 1 3 12 10 Pressure or vacuum actuated spring return 2/2 (diaphragm valve) Low pressure pilot actuated spring return 3/2 1 2 3 12 10 2 1 3 12 10 Low pressure pilot actuated pilot return, 3/2 1 2 3 12 10 2 1 3 12 10 Low pressure pilot actuated and returned, 3/2 1 2 3 12 10 2 1 3 12 10

147 Pilot actuated valves 1 2 3 12 10 Remote pressure bleed actuated spring return, NC, 3/2 2 1 3 12 10 Remote pressure bleed actuated spring return, NO, 3/2 12 2 10 1 4 5 3 14 Remote pressure bleed actuated spring return, 5/2

148 Pilot actuated valves Pilot actuated spring return, 4/2
1 2 4 3 14 12 Pilot actuated spring return, 4/2 1 2 4 5 3 14 12 Pilot actuated spring return, 5/2 1 2 4 5 3 14 12 Double pilot actuated 5/2 4 2 Differential pilot actuated 5/2 1 5 3 14 12

149 Pilot actuated valves 1 2 4 5 3 14 12 Pressure or vacuum actuated spring return, 5/2 (diaphragm valve) 1 2 4 5 3 14 12 Low pressure pilot actuated spring return, 5/2 1 2 4 5 3 14 12 Low pressure pilot actuated pilot return, 5/2 1 2 4 5 3 14 12 Low pressure pilot actuated and returned, 5/2

150 Pilot actuated valves 1 2 4 5 3 Double pilot actuated spring to centre all ports sealed 4 2 Double pilot actuated spring to centre supply port sealed 5 1 3 4 2 Double pilot actuated spring to centre supply to outlets 5 1 3

151 Mechanically actuated valves
NC NO 2 10 12 1 12 2 10 1 Plunger actuated spring return 2/2 1 2 3 12 10 1 3 12 10 2 Plunger actuated spring return 3/2 1 2 3 12 10 2 1 3 12 10 Plunger actuated air reset 3/2

152 Mechanically actuated valves
1 2 4 3 14 12 Plunger actuated spring return, 4/2 1 2 4 5 3 14 12 Plunger actuated spring return, 5/2 1 2 4 5 3 14 12 Plunger actuated air reset 5/2

153 Mechanically actuated valves
NC NO 2 10 12 1 12 2 10 1 Roller actuated spring return 2/2 1 3 12 10 2 1 3 12 10 2 Roller actuated spring return 3/2 1 2 3 12 10 2 1 3 12 10 Roller actuated air reset 3/2

154 Mechanically actuated valves
1 2 4 3 14 12 Roller actuated spring return, 4/2 1 2 4 5 3 14 12 Roller actuated spring return, 5/2 1 2 4 5 3 14 12 Roller actuated air reset 5/2

155 Mechanically actuated valves
NC NO 2 10 12 1 12 2 10 1 One way trip actuated spring return 2/2 1 2 3 12 10 2 1 3 12 10 One way trip actuated spring return 3/2 1 2 3 12 10 2 1 3 12 10 One way trip actuated air reset 3/2

156 Mechanically actuated valves
2 4 14 12 1 3 One way trip actuated spring return, 4/2 4 2 One way trip actuated spring return, 5/2 14 12 5 1 3 4 2 One way trip actuated air reset 5/2 14 12 5 1 3

157 Manually actuated valves
NC NO 2 10 12 1 12 2 10 1 Push button actuated spring return 2/2 1 2 3 12 10 2 1 3 12 10 Push button actuated spring return 3/2 1 2 3 12 10 2 1 3 12 10 Push button actuated air reset 3/2

158 Manually actuated valves
1 2 4 3 14 12 Push button actuated spring return, 4/2 1 2 4 5 3 14 12 Push button actuated spring return, 5/2 1 2 4 5 3 14 12 Push button actuated air reset 5/2

159 Manually actuated valves
NC NO 2 10 12 1 12 2 10 1 Lever actuated spring return 2/2 1 2 3 12 10 2 1 3 12 10 Lever actuated spring return 3/2 1 2 3 12 10 12 2 1 3 10 Lever actuated air reset 3/2

160 Manually actuated valves
1 2 4 3 14 12 Lever actuated spring return, 4/2 1 2 4 5 3 14 12 Lever actuated spring return, 5/2 4 2 Lever actuated air reset 5/2 12 14 5 1 3

161 Manually actuated valves
14 2 4 1 3 12 Lever actuated lever return, variable throttling, 4/2 2 4 12 1 3 14 Lever actuated lever return, variable throttling, detented, 4/2 14 2 4 1 3 12 Rotary knob actuated and returned, variable throttling, 4/2

162 Manually actuated valves
14 12 4 2 5 1 3 Lever actuated spring to centre all ports sealed 14 12 4 2 Lever actuated spring to centre supply port sealed 5 1 3 14 12 4 2 Lever actuated spring to centre supply to outlets 5 1 3

163 Manually actuated valves
1 2 4 5 3 14 12 Lever actuated, detented, all ports sealed centre 1 2 4 5 3 14 12 Lever actuated, detented, supply port sealed centre 1 2 4 5 3 14 12 Lever actuated, detented, supply to outlets centre

164 Manually actuated valves
NC NO 1 2 3 12 10 1 3 12 10 2 Pedal actuated spring return 3/2 1 2 3 12 10 2 1 3 12 10 Treadle actuated detented 3/2

165 Manually actuated valves
1 2 4 3 14 12 Pedal actuated spring return, 4/2 1 2 4 5 3 14 12 Pedal actuated spring return, 5/2 1 2 4 5 3 14 12 Treadle actuated detented 5/2

166 Manually actuated valves
1 2 4 5 3 14 12 Treadle actuated spring to centre all ports sealed 1 2 4 5 3 14 12 Treadle actuated spring to centre supply port sealed

167 Manually actuated valves
14 12 4 2 5 1 3 Treadle actuated, detented, all ports sealed centre 14 12 4 2 Treadle actuated, detented, supply port sealed centre 5 1 3

168 Manually actuated valves
1 2 3 12 10 Push button actuated rotary manual return 3/2 Push button actuated key return 3/2 2 12 10 3 1 Push actuated pull returned 3/2 1 2 3 12 10 Push actuated pull or air returned 3/2 1 2 3 12 10

169 Safety related valves Monitored dump valve Emergency stop valve
1 2 3 10 12 Monitored dump valve 1 2 3 12 10 Emergency stop valve 1 2 3 12 10 Soft start valve

170 Special purpose valves
1 2 3 Impulse generator

171 End

172 Symbol Library Vacuum Equipment

173 Vacuum equipment Vacuum generator Vacuum cups Vacuum switch pneumatic
NC NO 1 2 3 2 1 3 Vacuum switch pneumatic

174 Vacuum equipment Vacuum switch electric, normally open and normally closed V dc Analog out Switch out 0 V +V dc supply (brown) Analog out (white) Switch out (black) 0 V (blue) Vacuum transducer with analog and switched outputs npn Load V dc Analog out Switch out 0 V +V dc supply (brown) Analog out (white) Switch out (black) 0 V (blue) Vacuum transducer with analog and switched outputs pnp Load

175 Vacuum equipment Vacuum filter Vacuum silencer Vacuum gauge

176 End

177 End


Download ppt "For system diagrams and component identification"

Similar presentations