Presentation is loading. Please wait.

Presentation is loading. Please wait.

Measurement of “new” SPS-WS

Similar presentations


Presentation on theme: "Measurement of “new” SPS-WS"— Presentation transcript:

1 Measurement of “new” SPS-WS
N. Biancacci, F. Caspers, J. Kuczerowski, E. Piselli, C. Vollinger & others (for the impedance team) 22/09/2018

2 Measurements were carried out For different “states of assembly”:
0deg 90deg 45deg 135deg 180deg Measurements were carried out For different “states of assembly”: Empty Drum, Drum with fork and Cu-wire, Drum with fork, Cu-wire and “Fritz”-wire (W-wire); Ferrites (TT2-111R). 2. In different fork positions; Only measurements with fork are compared. 22/09/2018 Christine Vollinger, BE/RF

3 Christine Vollinger, BE/RF
Measurement of “new” SPS-WS Measurement with probes & Connectors on the fork (via hybrid) 22/09/2018 Christine Vollinger, BE/RF

4 Christine Vollinger, BE/RF
Goal of the Measurements: 1. To provide data for benchmarking of simulations. Measurements to be carried out on the structure in different configurations; Measurement with ferrites in a position “easy-to-place”, so that simulations with ferrite materials can be carried out. 2. Find mitigating measures to reduce the impedance from simulation (e.g. position of W-wire or a good ferrite location). W. Andreazzi 22/09/2018 Christine Vollinger, BE/RF

5 Christine Vollinger, BE/RF
Measurements for Fork Position = 0 deg 22/09/2018 Christine Vollinger, BE/RF

6 Christine Vollinger, BE/RF
Measurements for Fork Position = 45 deg 22/09/2018 Christine Vollinger, BE/RF

7 Christine Vollinger, BE/RF
Measurements for Fork Position = 90 deg 22/09/2018 Christine Vollinger, BE/RF

8 Christine Vollinger, BE/RF
Measurements for Fork Position = 135 deg 22/09/2018 Christine Vollinger, BE/RF

9 Christine Vollinger, BE/RF
Measurements for Fork Position = 180 deg 22/09/2018 Christine Vollinger, BE/RF

10 Christine Vollinger, BE/RF
Calculated Qs (unloaded) for 1st and 2nd Resonance What does that mean? 22/09/2018 Christine Vollinger, BE/RF

11 Christine Vollinger, BE/RF
Calculated Qs (unloaded) for 2nd Resonance TBC that this is really the unloaded Q…; For all fork positions, both measures, i.e. the “Fritz”-wire and the ferrite result in a reduction of Qunloaded ; This is our expectation & the effect that we wanted (?) 22/09/2018 Christine Vollinger, BE/RF

12 Christine Vollinger, BE/RF
Calculated Qs (unloaded) for 1st Resonance TBC that this is really the unloaded Q…; For the 0deg position, almost no effect on the Q is observed. The “Fritz”-wire and the ferrite both reduce the Q for all resonances except for the 2nd. Why? Again: Except for the 45deg position – this is our expectation & the effect that we wanted (?) What about all other resonances? 22/09/2018 Christine Vollinger, BE/RF

13 Christine Vollinger, BE/RF
Calculated Qs (unloaded) for 1st Resonance 22/09/2018 Christine Vollinger, BE/RF

14 Christine Vollinger, BE/RF
Measurement (Drum with Cu-wire at 45 deg Fork Position) Measurement (Drum with Cu-wire and Ferrite at 0 deg Fork Position) 22/09/2018 Christine Vollinger, BE/RF


Download ppt "Measurement of “new” SPS-WS"

Similar presentations


Ads by Google