ERYTHROCYTE SEDIMENTATION RATE (ESR)

Similar presentations


Presentation on theme: "ERYTHROCYTE SEDIMENTATION RATE (ESR)"— Presentation transcript:

1 ERYTHROCYTE SEDIMENTATION RATE (ESR)
Dr Maliha Sumbul

2 A simple non-specific screening test
CRP A simple non-specific screening test ( presence of disease, but not severity) Indirectly measures the presence of inflammation in the body It reflects the tendency of red blood cells to settle more rapidly in the face of some disease states, usually because of increases in plasma fibrinogen, immunoglobulins, and other acute-phase reaction proteins Changes in red cell shape or numbers may also affect the ESR

3 3 FACTORS: Erythrocytes:
- size/mass, -ve charge, agglutination, macrocytes, severe anaemia Plasma composition: single most imp factor - inc viscosity Mechanical / technical factors: - perpendicular, 3 degrees tilt = 30% error, vibrations

4 BLACK TOP (SODIUM CITRATE) PURPLE TOP ?

5 Westergren: WB ( 4 VOL) + 0.109 M TRISODIUM CITRATE ( 1 VOL )
OR EDTA BLOOD ( 4 VOL) + 0.9% SOD CHLORIDE ( 1 VOL ) [ 2 ML ML] Wintrobe: WB anticoagulated with EDTA [ 1 ML ] No dilution needed

6 METHOD  When anti - coagulated whole blood is allowed to stand in a narrow vertical tube for a period of time, the RBCs – under the influence of gravity - settle out from the plasma The rate at which they settle is measured as the number of millimeters of clear plasma present at the top of the column after one hour (mm/hr)

7 2 METHODS Westergren method Wintrobe Method
Each method produces slightly different results Most laboratories use the Westergren method

8 WINTROBE TUBE

9 WINTROBE TUBE WITH STAND
SMALL TUBE 100 MM BLOOD

10 WESTERGREN TUBE 30 cm long pipette 200 mm blood 2.5 mm int diameter

11

12 Westergren method: The Westergren method requires collecting venous blood into a tube containing sodium citrate It should be stored no longer than 2 hours at room temperature or 6 hours at 4 °C The blood is drawn into a Westergren-Katz tube to the 200 mm mark The tube is placed in a rack in a strictly vertical position for 1 hour at room temperature, at which time the distance from the lowest point of the surface meniscus to the upper limit of the red cell sediment is measured The distance of fall of erythrocytes, expressed as millimeters in 1 hour, is the ESR

13 Wintrobe method: The Wintrobe method is performed similarly except that the Wintrobe tube is smaller in diameter than the Westergren tube and only 100 mm long. EDTA anticoagulated blood without extra diluent is drawn into the tube, and the rate of fall of red blood cells is measured in millimeters after 1 hour.  The shorter column makes this method less sensitive than the Westergren method because the maximal possible abnormal value is lower. However, this method is more practical for demonstration purposes.

14 Red blood cells have settled,
leaving plasma at the top of the tube. Reading: 18 mm/hour (Time: one hour) This picture shows a rack holding Wintrobe tubes, in which anticoagulated whole blood has just been added. (Time: 0)

15 REFERENCE RANGE Wintrobe: Women: 0 – 20 mm/hr Men: 0 – 9 mm/hr
Westergren: Average values in healthy men/children are: 0 -10 mm/hr In healthy females, they are somewhat higher: 0 – 15 mm/hr The values are slightly higher in old age, in both genders REFERENCE RANGE Wintrobe: Women: 0 – 20 mm/hr Men: 0 – 9 mm/hr Old age=inc ESR ( DEC ALBUMIN)

16 Theoretical considerations
The RBCs sediment because their density is greater than that of plasma this is particularly so, when there is an alteration in the distribution of charges on the surface of the RBC (which normally keeps them separate form each other) resulting in their coming together to form large aggregates known as rouleaux. Rouleaux formation is determined largely by increased levels of plasma fibrinogen and globulins, and so the ESR reflects mainly changes in the plasma proteins that accompany acute and chronic infections, some tumors and degenerative diseases. In such situations, the ESR values are much greater than 20mm/hr. Note that the ESR denotes merely the presence of tissue damage or disease, but not its severity; it may be used to follow the progress of the diseased state, or monitor the effectiveness of treatment.

17

18 Some interferences which increase ESR:
increased level of fibrinogen, gamma globulins. technical factors: tilted ESR tube, high room temperature. Some interferences which decrease ESR: abnormally shaped RBC (sickle cells, spherocytosis). technical factors: short ESR tubes, low room temperature, delay in test performance (>2 hours), clotted blood sample, excess anticoagulant, bubbles in tube.

19 Chronic inflammatory disease (collagen and vascular diseases) increases ESR.
Polycythemia decreases ESR.

20 QUALITY CONTROL OF ESR once per week