Presentation is loading. Please wait.

Presentation is loading. Please wait.

EILERSEN The Weighing experts.

Similar presentations


Presentation on theme: "EILERSEN The Weighing experts."— Presentation transcript:

1 EILERSEN The Weighing experts

2 EILERSEN The Weighing experts
A Danish manufacturer, established since 1969, who designs and builds uniquely engineered and patented weighing products for severe industrial, mobile and sea mountable application sites The Weighing experts

3 EILERSEN manufactures load cells, instrumentation and communications modules that are all designed to work together to make your weight based process control systems simple to implement on the shop floor, on board your truck, or aboard ships at sea.

4 EILERSEN load cells are easy to install
EILERSEN load cells are easy to install. Mount the base plates, level, insert the load cell into the top capture ring, and route your coaxial cable. Your ready to begin weighing. If there is concern about up lift, a simple upload checking mechanism can be installed as shown below.

5 CL series load cell with hygienic base
Eilersen also has a series of Hygienic load cells and base plates for clean room environments Fasteners and their threads are not exposed to the possibility of contamination. CL series hygienic base plate with hidden fasteners, or a more standard base plate style are both available

6 No longer will you need to connect “fiddly” little wires in the field.
Simply add the clamp on connector and screw it into the load cell – done. If you have ever hooked up your TV cable connection at home – this is the same process. Load cell cables are field repairable or replaceable without re-calibration of the weighing system. Even if you change the length. Cables are RG58 co-axial with BNC connectors and can be up to 100m (325-ft) long per load cell. No longer will you need to connect “fiddly” little wires in the field. Cables are available with a variety of coverings, ex. Teflon, for specific application requirements Even without the cable installed, the load cell is still hermetically sealed

7 Simple installations are further realized by the fact that all EILERSEN load cells are calibrated at the factory. Simply zero the deadload of the system, check for binding, and your system is running and calibrated. The load cell outputs are actual weight values being sent via a RS485 serial output to an EILERSEN weight display or communication j-box that transmits to a PLC/PC.

8 Display screens and instrumentation are available in a variety of configurations and enclosure types. If you do not need a display we can provide “blind” instruments to embed inside your control panels.

9 Various communications modules are available for your PLC or PC connections.
Ethernet IP EtherCAT Profibus DP ProfiNet DeviceNet Serial RS232/422/485 Modbus ASCII/ RTU Analog Output (0-10V, 4-20mA) Digital IO (DIO) Typical “blind” system. Setup through the PLC HMI screen and dip switches.

10 No matter if you are working with a single load cell or with multiple load cell system, you have a choice of reading a summed signal, or each individual load cell in the system. Set the desired output type during your setup routine. Imagine the cost advantage of multiple load cell inputs to a single communication port. This also means you could have 4 separate scales being input through the same communication module.

11 So how can this technology cure so many of the problems of strain gage load cells?
Load is applied here So until the load cell flexure is physically destroyed the load cell works! and The flexures are thicker in a capacitance load cell and deflect less than 0.1mm at full loading. The sensors do not touch the body of the load cell that is flexing under load. m The load cell is attached here to ground

12 EILERSEN load cells are just as flexible in use as the more typical strain gage based systems. Here you can see a variety of single point load cell applications for various overhanging hoppers. The impact and overload resistance of the technology makes mounting much easier in OEM machinery. Over hangs to 600mm (24”) can be supported with some of our load cells.

13 Bending beams available to 7000-kg (15,400-lbs) capacity
Beam load cells used in overhead weighing or portable carts applications. Bending beams available to 7000-kg (15,400-lbs) capacity Beam load cell used in on-board truck weighing. Bolt to the frame and support the truck body on 4 or 6 load cells. Capacitance beam load cells can also be used in heavy vibratory machinery

14 Capacitance based compression load cells can be used in a wide variety of application sites, even those with severe startup or side load forces. Installation remains simple even in these sites. Capacities to 500-tons (1,100,000-lbs) are available.

15 EILERSEN’s weighing products support many types of weighing applications, both plant and mobile requirements are equally supported.

16 When you have a difficult application site that is causing difficulties, you may wish to take a look at a technology designed specifically for those types of environments.


Download ppt "EILERSEN The Weighing experts."

Similar presentations


Ads by Google