1 CENELEC TC215 WG3 (EN 50600 Series)
JTC1 – SG-EEDC CENELEC TC215 WG3 (EN Series) Prepared by: M Gilmore Country: UK

2 CENELEC TC215 WG3 (EN 50600 series)
Name of organisation and associated bodies CENELEC Technical Committee TC215 “Electrotechnical Aspects of Telecommunication Equipment” WG3 “Facilities and infrastructures” Description of what this organisation is addressing First project: EN 50600 Addressing the design of data centre facilities and infrastructures based on the following critieria Availability Physical security Energy efficiency enablement Providing the infrastructure necessary to measure, report and control the energy efficiency of a data centre addressing: Building construction Power distribution Environmental control Telecommunications cabling infrastructure Security Management and operational information Who are the consumers Designers and operators of data centres?

3 CENELEC TC215 WG3 (EN 50600 series)
Taxonomy, terms, definitions and metrics used and introduced. Data centres adopt the widest possible definition No restriction on size No restriction on purpose/business model No metrics used – the purpose of the EN series is to provide an infrastructure that enables the measurement and control of energy consumption and related parameters within a data centre, not how the data should be used (this matches the proposals being submitted by CENELEC BT WG 132-3) Standards (certification) being proposed, developed or suggested. Current Standards Planned delivery 2011 Standards structure shown of the next slide

4 CENELEC TC215 WG3 (EN 50600 series)
Building construction EN Power distribution EN Environmental control EN Telecomm’s cabling infrastructure Annex A Risk assessment EN Security systems EN Management and operational information Annex B General design principles EN General concepts Annex C Measurement methodologies, test procedures and report formats DATA CENTRE CLASSIFICATION availability security energy efficiency enablement

5 CENELEC TC215 WG3 (EN 50600 series)
How does this relate to the scope of EEDC The objective of EN series documents is to ensure that future data centres have the capacity to measure, control and monitor energy usage.

6 CENELEC TC215 WG3 (EN 50600 series)
Source material, references. First drafts of EN series will be circulated Q4, 2010

7 Tick areas relevant to EEDC scope (excel doc separate) If required add new column for scope topic