1 Training Presentation
IRRInet ACE/M System PRODUCT INTRODUCTION Training Presentation Presented By: Doron MOTTEC Updated: July 17th , 2008

2 Major topics covered by this presentation
Agenda IRRInet – System Configuration IRRInet-M IRRInet-ACE Legacy and “New” Field Units Migration IRRInet System – Radio Compatibility IRRInet System – On-Site Programming ICC IRRInet System – Configuration Tools New deliverables summary

3 Communication Network
Control Center IRRInet – System Configuration Service (STS) ICC Client ICC Server IFI Communication Network Field Units IRRInet-M (Master) IRRInet-ACE IRRInet-XL/XM ICC Terminal DTMF (SMS) Remote I/Os Piccolo-RTU Scorpio Impact IRRInet-M (Slave) Piccolo-XR

4 IRRInet-M

5 IRRInet-M - General View
IRRInet-M AC 24VAC Power In (AC) Commonality Inputs/Outputs - 12 Outputs, 4 DI on the Basic board - 12 Outputs, 4 DI on the Expansion board Communication Ports: - RS232/485 - RS232 - Radio/Line Power: - 12V DC in - 5, 7.5, 9.6, 12V DC (Maximum 15 Watt / 2 Amp) Power out for portable radio 20 LED for Status display 1 Push button (various functions) 12VDC Power In Relay outputs for Solenoids: 24V AC or, External power connection IRRInet-M DC 12VDC Power In DC Latch Solenoids activated by 3300 µF 35 VDC capacitor

6 IRRInet-M – Master/Slave configuration (1)
IRRInet-M supports 3 modes of operations RTU (loaded with IRRI 7.0 Master) Performing all irrigation functions (IRRIV Capabilities) Reporting to the ICC, Via the MDLC Cloud Stand Alone (loaded with IRRI 7.0 Master) Performing all irrigation functions as a stand-alone unit when the system is configured without an ICC Remote I/O (loaded with IRRI 7.0 Slave, PRIS or MDLC) Serving as a Distributed I/O for another unit (Master) Please note! In the PAST, whenever using SCORPIO or IRRIcom, it was ALWAYS as a Remote I/O to a Master IRRInet… With IRRInet-M, this is NOT a MUST anymore! Use the Slave option only when needed!!

7 IRRInet-M – Master/Slave configuration (2)
MDLC ICC FIU Master Slave Loaded with IRRIV 7.0 Slave Master Master Loaded with IRRIV 7.0 Master Slave

8 IRRInet-M – RS485 Port Options (2)
Remote I/O (Slave) to IRRInet-ACE Master Remote I/O (Slave) to IRRInet-M Master PIU Connectivity (Piccolo-XR) MDLC Connection to ICC MDLC

9 IRRInet-M – RS232 Port Options (2)
Connection to ICC Serving as an FIU Remote I/O (Slave) to IRRInet-ACE Master Remote I/O (Slave) to IRRInet-M Master PIU Connectivity (Piccolo-XR) MDLC Connection to ICC MDLC

10 IRRInet-M – Radio Port Options (2)
Remote I/O (Slave) to IRRInet-ACE Master Remote I/O (Slave) to IRRInet-M Master IRRInet-M “disguised” As Scorpio or IRRIcom Radio connection to Legacy Remote I/O MDLC Connection to ICC MDLC

11 IRRInet-M – Line Port Options (2) (it is Radio or Line, Configurable)
Remote I/O (Slave) to IRRInet-M Master MDLC Connection to ICC MDLC

12 IRRInet-M AC, Power-in Connections
RS232 or RS485 RS232 only 3A Fuse (user-supplied) + For Radio Communication - For Radio Power: 5, 7.5, 9.5, 12 VDC, Maximum 15 Watt / 2 Amp Programmable Optional 12 VDC Operating the Logic Board Port 3 for Line Communication 3A Fuse (user-supplied) OR Up to 7A Fuse when unit is installed in a closed NEMA BOX Grounding 24 VAC for Logic Board and I/O operation Over Current Detection (8A)

13 IRRInet-M AC I/O Connections (Internal 24 VAC)
Main Board 1A per output Max, 6 Amp Total Grounding Expansion Board

14 IRRInet-M AC I/Os Connections (External 24 VAC)
Main Board Please note! The relays may operate the solenoids using external WET Power. Up to 60 VDC or 24VAC ± 20%. Programmable per I/O board! Recommended 3A FB Fuse 1A per output Max, 6 Amp Total Over Current (8A) Protection Grounding Expansion Board

15 IRRInet-M DC, Power-in Connections
RS232 or RS485 RS232 only 3A Fuse (user-supplied) For Radio Communication + For Radio Power: 5, 7.5, 9.5, 12 VDC, Maximum 15 Watt / 2 Amp Programmable - Port 3 for Line Communication Optional 12 VDC Operating the Logic Board Grounding

16 IRRInet-M DC I/Os Connections
Main Board Capacitor µF 35 VDC Discharge Voltage – 4 to 35 VDC (Configurable) Pulse Width: up to 120mSec Grounding Open Loop and Short Detection Expansion Board

17 IRRInet-M – LED Matrix and Push Button
Activates LED Matrix LEDs Test Scrolls between LEDs various modes Reset and Download LED Matrix CPU and Communications I/Os Status Error Logger

18 IRRInet-M - SW Features
IRRInet-M supports 3 modes of operations RTU (loaded with IRRI 7.0 Master) Performing all irrigation functions (IRRIV Capabilities) Reporting to the ICC, Via the MDLC Cloud Stand Alone (loaded with IRRI 7.0 Master) Performing all irrigation functions as a stand-alone unit when the system is installed without an ICC Remote I/O (loaded with IRRI 7.0 Slave, PRIS or MDLC) Serving as a Distributed I/O for another unit (the Master) Capacity 250 Outputs 250 Inputs 125 Main Lines 200 Programs 200 Groups 50 Fertilizer Pumps 50 Filter Batteries User Configuration Solenoid Operation Voltage (IRRInet-M DC) Radio Operation Power (AC and DC) External/Internal Relays Power Switching (IRRInet-M AC)

19 IRRInet-ACE

20 IRRInet-ACE - General IRRInet-ACE is ACE3600 with the Irrigation (IRRIV) Application IRRInet-ACE is available as MASTER only IRRInet-ACE supports ALL of the ACE3600 I/O Modules IRRInet-ACE does not have DC latch I/O Board – can use IRRInet-M DC for this purpose

21 IRRInet-ACE – RS485 Port Options
MDLC Master of remote I/O at IRRInet-M Slave/Router MDLC Connection to ICC Slave/Router Legacy Scorpio/Impact PIU Connectivity (Piccolo-XR)

22 IRRInet-ACE – RS232 Port Options
MDLC MDLC Connection to ICC Connection to ICC Serving as an FIU Master of remote I/O at IRRInet-M Slave/Router Slave/Router Legacy Scorpio/Impact PIU Connectivity (Piccolo-XR)

23 IRRInet-ACE – Radio Port Options
MDLC Connection to ICC MDLC Connection to ICC MDLC MDLC Connection to Slave MDLC Connection to Slave Slave (anywhere in the Communication Network)

24 IRRInet-ACE – Ethernet Port Options
MDLC Connection to ICC MDLC Connection to ICC MDLC MDLC Connection to Slave MDLC Connection to Slave Pending the availability of a terminal server supporting PPP (like the IP Soap-Dish) – OR use GPRS modem (available now)

25 IRRInet-ACE - SW Features
IRRInet-ACE supports Master Application Only Capacity 500 Outputs 500 Inputs 250 Main Lines 400 Programs 400 Groups 100 Fertilizer Pumps 100 Filter Batteries

26 Legacy and “New” Field-Units - Migration

27 Q: When should I use IRRInet-M and when should I use IRRInet-ACE
Q: When should I use IRRInet-M and when should I use IRRInet-ACE? A: Below… MDLC FIU IRRInet-ACE ICC IRRInet-M Design Guidelines: Communication Media larger variety (Ethernet built-in) on IRRInet-ACE Line needed? Available ONLY on IRRInet-M Number of needed Ports (only 3 on IRRInet-M, 5 on IRRInet-ACE I/O specification DC solenoids, only on IRRInet-M Analog I/O only on IRRInet-ACE I/O count Up to 24 Outputs and 8 inputs on IRRInet-M, up to 8 Modules on IRRInet-ACE Custom Programmability (RUNGS) needed? Only on IRRInet-ACE Weather Station (WeatherCon) support? Only on IRRInet-ACE Analog needed? Only on IRRInet-ACE

28 Q: I need to add a new device to a network that already has Scorpio(s) or IRRIcom(s). What do I do? A: Below… FIU MDLC ICC Please note! Load IRRIV Master for direct connection to ICC or, Load IRRIV Slave with PRIS protocol to report to the legacy IRRInet-XL/XM Upgrade to MDLC later! IRRInet XL/XM IRRIcom Scorpio IRRInet-M

29 Q: I have an IRRInet XL/XM I need to replace, or add. What do I do
Q: I have an IRRInet XL/XM I need to replace, or add. What do I do? A: Below… FIU MDLC ICC Option B IRRInet-ACE IRRInet XL/XM Master Option A IRRInet-M

30 IRRIcom Link is NOT supported (hard-coded timing in IRRIcom prevents)!
Q: I need to add IRRInet-ACE, but this unit MUST operate the legacy Scorpio, IRRIcom or Impact. What do I do? A: Below… Please note! The IRRInet-M will route the PRIS commands to the legacy units. It may serve, at the same time, as a Slave unit as well. MDLC FIU ICC IRRInet-ACE RS485 IRRInet XL/XM IRRInet-M Router Slave Scorpio Impact IRRIcom IRRIcom Link is NOT supported (hard-coded timing in IRRIcom prevents)!

31 A. Connect IRRInet-M to the IRRInet-ACE to serve as its I/O board
Q: The IRRInet-ACE does not have dedicated Modules for Irrigation, So…? A: Below… MDLC FIU ICC IRRInet-ACE RS485 IRRInet-M A. Connect IRRInet-M to the IRRInet-ACE to serve as its I/O board (AC and/or DC) B. Use the ACE’s Relay I/O Module for AC solenoids, or any other ACE original I/O Module suitable for irrigation

32 SW Versions Matrix Compatibility
STS Software V11.70+ IRRInet– ACE FW- V11.05+ PLZ- V7.00+ ICC Ver IRRInet–M (Master) FW- V5.00+ FLS- V7.00+ FIU (Super CPU) IFI Comm. Network (Type A-INTRAC/PRIS) MDLC Comm. Network (Type B - MDLC) IRRInet – XL FW- V9.27 FLS- 5.70 IRRInet– XM FW- V9.27 FLS- V5.70 MIR5000 AC FW – V3.51 IRRInet FM – V1.96 PIU FW- V1.20 IRRIcom FLS-V4.07 IRRInet-M (Slave) FW V5.00+ FLS – V7.00+ Impact Scorpio FM – V2.02 Impact Scorpio FW-V2.02 IRRIcom FLS-V4.07 IRRInet-M (Slave) FW V5.00+ FLS – Piccolo-XR FW-V1.20

33 Basic design guidelines, per radio link, to consider…
All radios must be configured to the same channel spacing (12.5 or 25Khz) Warm-up time and channel monitor resolution should be equal in all radio types and configured to the worst case time (longest). When adding new IRRInet-M to a radio link all existing units’ warm-up time should be increased to 400msec. The combination of RTU and Radio audio response must be either Flat or Pre-emphasis De-Emphasis across ALL radios. Mobile radios, like CM200, CDM750 should be configured to Flat audio mode. Portable radios, like HT750, GP320 are by default configured to Pre/De-Emphasis. They should be reconfigured to Flat audio mode if this is required for the radio link. Type of radio network protocol – MDLC or INTRAC (PRIS) should ALWAYS be considered and appropriate radio path study performed.

34 IRRInet System – ICC

35 ICC V 14.0 - New Features Supporting New Field Units
IRRInet-M AC IRRInet-M DC IRRInet-ACE IP Connection with no IFI (Applicable for new field units only – PURE ACE / M environment – existing systems must keep FIU due to MDLC routing limitations of XL/XM)

36 ACE3600 System Tool Suite (STS)
ICC Models and Options F2000 (V14.X) for 1 Field Unit Only V387 to order ICC supporting 1-9 Field Units V388 to order ICC supporting Field Units, and/or supporting network ACE3600 System Tool Suite (STS) STS Software F7500 (V11.7)

37 IRRInet System – Configuration Tools

38 IRRIcom Service Toolkit – V2.5
Configuration Tools STS V11.70 The new STS (ACE3600 Configuration Tool), is used to configure the IRRInet-M and the IRRInet-ACE MOSCAD Toolbox V This SW is used to configure IRRInet-XL/XM DIOS Service Toolkit V1.60 This SW is used to configure the PIU and Piccolo-XR IRRIcom Service Toolkit – V2.5 This SW is used to configure the “Legacy” IRRIcom” IRRIV4