Presentation is loading. Please wait.

Presentation is loading. Please wait.

Florida Gas Transmission 18-Inch Mainline Hydrostatic Test

Similar presentations


Presentation on theme: "Florida Gas Transmission 18-Inch Mainline Hydrostatic Test"— Presentation transcript:

1 Florida Gas Transmission 18-Inch Mainline Hydrostatic Test
From the Golden Glades Interchange to the interchange of NW 122nd Street with the Palmetto Expressway Miami-Dade County

2 Today’s Outline Who is Florida Gas Transmission (FGT)?
Why is FGT testing? What is the test exactly? When will the test occur? Where will the test take place? How will the test be conducted? How will the test affect me?

3 Florida Gas Transmission Company
Natural gas transmission company operating a 5,000 mile pipeline system along the Gulf Provide all of the natural gas for power generation in Miami-Dade County 18” diameter Mainline serving South Florida Customers include: Electric utility companies Local distributors Industrial clients

4 Need for the Test The U.S. Department of Transportation regulates all interstate pipelines Testing is federally mandated Best practice to confirm the safety and reliability of the pipeline Safety is our #1 priority Ensure continued superb customer service

5 Nature of the Test Hydrostatic Test
Remove the natural gas from the line Controlled release vents harmlessly into atmosphere Service is maintained on another system Test the integrity of the pipeline by filling the line with water Put the water under pressure for a fixed period of time

6 Background Hydrotesting the 18-inch pipeline system
Standard, common pipeline test procedure Recent, successful pipeline tests were completed in: Began Miami-Dade testing February 2011 Hillsborough Broward Martin Pinellas Palm Beach Miami-Dade Polk St. Lucie

7 Prepare System for Testing
Project Process Begin Project Obtain Permits Prepare System for Testing Conduct Hydrotest End Project Public Awareness Campaign

8 Project Schedule Test window is set: Wednesday, 19 April 2017
TASK DATE Community Awareness November – May Permit Applications November – February System Preparation January – February Test Preparation February – March Conduct Hydrotest 19 April 2017 Test window is set: Wednesday, 19 April 2017 Early morning, midnight – 4:00 a.m.

9 Project Location Total Project Length = 10.2 miles
Begin: Golden Glades Interchange End: NW 122nd Street Generally, along the Palmetto Expressway Within the limits of: City of Miami Gardens Town of Miami Lakes City of Hialeah Unincorporated Miami-Dade County

10 Project Location (con’t)
Project Limit N

11 How the Test is Performed
Remove natural gas from the pipeline Completed the week before the hydrotest Fill the line with water Pressurize the system Normal operating pressure is 722 PSI Test pressure is up to 1,444 PSI Relatively short duration (approx. 30 minutes) Reduce to intermediate pressure at 1,083 PSI Maintain for 8 hours

12 How the Test is Performed (con’t)
De-pressurize the line Drain the water from the system If any integrity issues are found: They are corrected as soon as possible The hydrotest is performed again Any re-testing must be performed within the prescribed test window timeframe Resume normal natural gas service

13 Safety During the Test Safety is our #1 priority
Performed extensive test preparations, including an inspection of the entire system Any pipe anomalies will be repaired in advance of conducting the hydrotest For the duration of the high pressure test, as a safety consideration, we plan to isolate sections of the pipeline route from people and traffic

14 Conducting the Test Advance Preparations
Make all key stakeholders aware Adjacent property owners Emergency service providers General driving public Announcements Flyers, newspaper, FL511, website, etc. Dynamic message signs 2 weeks in advance

15 Conducting the Test (Con’t)
Night of the Test Begin at midnight Close ramps/roads/lanes with barricades Law enforcement support Confirm all-clear along the 10.2-mile corridor Conduct hydrotest Reopen roadways at approximately 4:00 AM

16 Traffic Control During the Test
General Utility Permit from the Florida Department of Transportation is in process Officers will be stationed at road and lane closures Emergency responders will be able to cross as needed Detours will include signs and officer support

17 Project Location – District 1

18 Project Location – District 13

19 Project Location – District 12

20 For More Information Please visit our website: www.fgthydrotest.com
Or contact FGT: Mr. Terry Coleman 2405 Lucien Way, Suite 200 Maitland, FL 32751 Toll Free – 844.FGT.INFO ( ) Office – Fax –

21 FGT 18” Mainline Hydrotest Summary
Federal mandate Testing with water Test window is set for Wednesday 19 April 2017 Midnight – 4:00 AM Road closures with law enforcement Frontage roads Cross streets On- and off-ramps Emergency vehicles can always cross Project Limit N

22 Thank You


Download ppt "Florida Gas Transmission 18-Inch Mainline Hydrostatic Test"

Similar presentations


Ads by Google