1 ABB PIR3502, PUV3402 & PFO3372 Level 2 Sales Training Multiwave Photometers Miscellaneous Applications April 26, 2006

2 PIR3502 or PUV3402 “Multiwave” Photometer

3 Refinery Applications

4 Refinery Applications
Absorbance at a given wavelength Color measurments in heavy crude (PUV3402) ASTM Color Units Saybolt Color Units APHA Color Units Also know as: Hazen Color Platinum Cobalt Color Primarily used in the Chemical Industry ABB Solution for Clause Process Acid Gas Feed to Primary Clause Reactor Sour Gas Feed to Primary Clause Reactor Sulfur-Pit Monitoring

5 Monitoring Absorbance at a Particular Wavelength
Measurement: Absorbance measurement a specified Wavelength and Path length Refiners consider the measurement proprietary Not the same wavelengths are used IR, NIR and UV have been requested Process Benefit Continuous monitoring for a specific compound or property Measurements located early in the refining process Benefits Provided by Multiwave Can be configured for operation in the IR, NIR or UV spectral regions Inexpensive analytical solution High precision analyzer Excellent signal to noise ratio Excellent repeatability

6 Color Measurements made in Visible Region: PUV3402

7 Refinery Color Measurements: ASTM Method D156
-15 to +30 Saybolt Color Units Process Benefits Used primarily in the following products: Gasoline Jet Fuel Naphtha Kerosene Quality measurement Benefits Provided by Multiwave Isolated/Heated sample cell allows for measurements of viscous samples by keeping it hot Multiple Wavelength capability will allow for Saybolt and ASTM color measurements to be done on 1 analyzer as long as ranges are compatible Reliable analyzer designed for process with over 99% up-time

8 Refinery Color Measurements: ASTM Method D1500
0-8 ASTM Color Units Process Benefits Used primarily in the following products: Lube Oils Heating Oils Diesel Fuel Petroleum Waxes Quality measurement Benefits Provided by Multiwave Isolated/Heated sample cell allows for measurements of viscous samples by keeping it hot Multiple Wavelength capability will allow for Saybolt and ASTM color measurements to be done on 1 analyzer as long as ranges are compatible Reliable analyzer designed for process with over 99% up-time

9 ASTM Color

10 Chemical Plant Multiwave Applications

11 TAME or MTBE Plants Measurement Process Benefits Benefits of Multiwave
0-20% Methanol in C4 or C5 background Process Benefits Improved tower control Increased catalyst life If methanol concentration gets too high then it kills the catalyst Measurement can be made in various parts of the tower Benefits of Multiwave Unique combination of wavelengths Non-traditional wavelengths for alcohol measurement Allow ABB to make the measurement where others have failed

12 Ethylene Glycol Production Typical Applications
Moisture Measurements Reactor Outlet Dryer Inlet Dryer Outlet Quality Control Measurement Purity Measure percent transmittance at 4 UV wavelengths

13 Moisture in Glycol Applications
Measurements Dryer Inlet: 0-5% Water Dryer Outlet: ppm Process Benefits Allows real time monitoring of dryer performance Reduced off spec material Less product recycle to dryer Reduced product over drying Reduced operational costs Increased dryer capacity Benefits Provided by Multiwave Dynamic Sample Temperature Compensation Improves measurement precision Developed as part of method Reduced SHS Costs More relaxed sample temperature control requirement +/- 10º C sample temperature change will have less than +/- 1% of full scale affect on the measurement

14 Dryer Applications Dryer Inlet Measurement: Stream Composition
0-5% Water in MEG Stream Composition MEG 99.9% DEG ppm TEC 200 ppm Water 2% Dryer Outlet Measurement: ppm Water in MEG Stream Composition MEG % DEG ppm TEC ppm Water ppm MEG = Monoethylene Glycol DEG = Diethylene Glycol TEG = Triethylene Glycol

15

16 Ethylene Glycol Purity Measurement (Slide 1)
Percent Transmittance at four wavelengths 220 nanometers 250 nanometers 275 nanometers 350 nanometers Process Benefits Improved Process Control Continuous measurement allows production to make process changes as needed Reduced off-spec material to be re-worked Reduced product storage Product can go from reactor to tank car Quality Control Department No delays in waiting on lab analysis Entire product is analyzed – not pulled samples Quicker release for custody transfer

17 Ethylene Glycol Purity Measurement (Slide 2)
Benefits Provide by Multiwave Continuous measurements of all four wavelengths on one analyzer Economic solution Precise measurement Low zero drift for UV analyzer Automatic zero with double de-ionized water Optical span filter for calibration check High online availability (+99.5%)

18 Glycol Purity Analyzer

19 Urethanes/Polycarbonates Industries
0-200 ppm Chlorine in Phosgene (UV, Vapor) 0-200 ppm Chlorine in HCl (UV, Vapor) 0-200 ppm Phosgene in HCl (IR, Vapor) 80-100% Phosgene (IR, Vapor) 0-100 ppm Toluene diisocynate in ODCB (IR, Liquid) 0-70% Phosgene in ODCB (NIR, Liquid)

20 Maleic Anhydride

21 Maleic Anhydride Process
OFFGAS MULTIWAVE Butane, CO, CO2 & Maleic Anhydride FEED MULTIWAVE Butane and Water Vapor BUTANE AIR REACTOR FEED REACTOR OFFGAS

22 Maleic Anhydride Reactor Feed
Measurements Butane % Water Vapor 0-5% Process Benefits Allows continuous monitoring of feed stream Butane Analysis Fast analysis allows for operation close to the LEL of the stream Maximizes process yield Safe operation of process by not exceeding LEL of Butane Water Vapor measurement Optimizes reactor control Benefits Provided by Multiwave Multi-component analysis allows both measurements on one analyzer Heated Sample Cell Improves response time to a water concentration change Sample can be run at elevated pressure so it can be returned to process

23 Maleic Anhydride Reactor Outlet
Measurements Butane % Carbon Monoxide 0-2% Carbon Dioxide 0-2% Maleic Anhydride 0-2% Process Benefits Allows continuous monitoring reactor outlet Improves reaction efficiency Allows for monitoring when catalyst needs regenerated Hot and Wet Analysis Allows for measurement of Maleic Anhydride Faster response time than scrubbed sample No hazardous chemical disposal issue Allows for Mass Balance calculations Benefits provided by Multiwave Multi-component analysis allows all four measurements on one analyzer Lower Maintenance time and costs Only need to maintain 1 analyzer Heated Sample Cell Allows measurements to be made hot and wet Cell can be heated to 180C for the high dew point application Sample can be run at elevated pressure so it can be returned to process No scrubber system to maintain

24 Urethanes/Polycarbonates Industries
0-200 ppm Chlorine in Phosgene (UV, Vapor) 0-200 ppm Chlorine in HCl (UV, Vapor) 0-200 ppm Phosgene in HCl (IR, Vapor) 80-100% Phosgene (IR, Vapor) 0-100 ppm Toluene diisocynate in ODCB (IR, Liquid) 0-70% Phosgene in ODCB (NIR, Liquid)

25 IF A MEASUREMENT CAN BE MADE ON A IT SHOULD BE MADE ON A MULTIWAVE
BREWER’S LAW IF A MEASUREMENT CAN BE MADE ON A MULTIWAVE IT SHOULD BE MADE ON A MULTIWAVE