Presentation is loading. Please wait.

Presentation is loading. Please wait.

Status Report of EDI on the CAA

Similar presentations


Presentation on theme: "Status Report of EDI on the CAA"— Presentation transcript:

1 Status Report of EDI on the CAA

2 CAA Public website All pages fully accessible by anyone

3 CAA Test Area Currently services accessible only by ESTEC/ESAC
Individual instrument team members will be allowed on a need basis Some of the CAA Command-line services are available to all

4 CSA Public website

5 EDI Datasets for Downloading

6 CSA EDI Graphics

7 EDI Status Information
panel1: EDI general – NOT DONE YET mode__C1_CQ_EDI_CLIST [value -1, 0, 1]; note that -1 needs to be generated Status__C*_CP_EDI_AE, bit 0 [value 0 or 1] Status__C*_CP_EDI_AE, bit 1 [value 0 or 1] crf__C1_CP_EDI_CRF, float, values up to ~20 (kHz] code_flag__C1_CP_EDI_CRF [value 0 or 1] panel2: Status__C*_CP_EDI_MP status[1]: 0, 1, 2        -> plot: status[1]                   values=0, 1 or 2 status[2]: 0, 100        -> plot: status[2]/100          values=0-1 status[3]: 0-100        -> plot: status[3]/100          values=0-1 status[5]: 0-100        -> plot: status[5]/100          values=0-1 status[6]: no idea of max value status[7]:0-180         -> plot: status[7]/90             values=0-2 panel3: Status__C*_CP_EDI_MP status[4]: integer value between  0-255        seven bits can be set -> resolve bits plot seven bits: if bit is set, it has value = 1, else = 0

8 EDI Status Information

9 CAA EDI QL Should one have one plot for each spacecraft? Either 3- or 24-hr plots Combine observations from both AE and E-field modes Add auxiliary information This could be generated by the CAA using the calibrated data products

10 EDI inconsistencies Notes:
All QZC counts = 0 => not displayed Notes: If EGD exists, there is a chance for PP/SPIN/MP If EGD does not exist, no chance for PP/SPIN/MP QZC and CRF should exist always in EF-mode, so they should have the same coverage as CLIST/EF-mode PP and SPIN should have identical coverage MP should have a wider coverage than PP/SPIN (all qualities)

11 Dataset Inventory Analysis
There are several similar datasets where the main difference is that data vectors or matrices are converted into another system. For instance, scientific data are given in different scientific units or coordinate systems Consistence of such datasets have never been investigated although there is some evidence that some errors can occur Such similar datasets can often be expected to have the same number of records Exception: if a dataset is given in raw units, the corresponding datasets in scientific units may have less records if poor records were deleted However, if poor data have been replaced with FILLVAL, the same number of records should exist In addition such datasets should have similar values for Version numbers Generation and ingestion dates Note: these metadata can have significant differences, so there is no automatic CAA has developed a tool that collects such metadata and gives them in a text file

12 Inventory Output The beta version of the inventory tool is available (currently) at Inventories are executed a few times a week, the inventory generation date is shown in the header of the inventory

13 Example: PP – SPIN datasets
Inventory analysis for C3 "Spin resolution" (C3_EDI_SPIN). Compared datasets: 1: C3_PP_EDI 2: C3_CP_EDI_SPIN Generation date: :32:31 Analysis is based on the database content at :25:12 Data coverage: T00:00:00Z/ T00:00:00Z Processing policy: - DON'T CHECK FILES - DON'T CHECK NUMBER OF RECORDS - DON'T CHECK TIMESTAMPS - DON'T CHECK FILE VERSIONS - DON'T CHECK IF GENERATION DATES ARE WITHIN 90 DAYS - CHECK IF DATASET 1 IS THE OLDEST ONE - EXTEND FILE TIME SPAN - IGNORE LAST FILE IF UNTIL AROUND 2020 - SPECIAL EDI 1: - CHECK NUMBER OF RECORDS AND TIMESTAMPS ONLY IF THE NUMBER OF RECORDS IN PP_SPIN IS LARGER THAN 0 AND IN CP_EDI_SPIN DIFFERENT THAN 1 (ERR R, T) - REQUIRE THAT EDI_SPIN FILE DOESN'T EXIST DURING PROBE FAILURES: - C1: from - C2: from

14 Example: PP – SPIN datasets
Date OK? ERR R R2 V1 V G G I I2 ERR F T15:11:44Z T17:37:17Z ERR F T14:05:28Z T15:30:41Z ERR F T15:28:00Z T08:27:32Z ERR F T15:28:00Z T08:27:48Z ERR F T09:47:18Z T17:23:00Z ERR F T09:47:28Z T17:23:12Z ERR F T15:45:35Z T08:35:08Z ERR F T15:45:36Z T08:35:10Z ERR F T15:45:37Z T08:35:12Z ERR F T15:45:38Z T08:35:14Z ERR F T15:45:39Z T08:35:16Z ERR F T15:45:40Z T08:35:19Z ERR F T15:45:41Z T08:35:22Z ERR F T15:45:42Z T08:35:24Z ERR F T15:45:43Z T08:35:27Z ERR F T15:45:44Z T08:35:29Z ERR F T15:45:45Z

15 Example: EDI – AE datasets
Inventory analysis for C1 "Ambient Electron Counts" (C1_EDI_AE). Compared datasets: 1: C1_CP_EDI_AE 2: C1_CP_EDI_AEDC Generation date: :32:31 Analysis is based on the database content at :25:04 Data coverage: T00:00:00Z/ T23:59:56Z Columns description: Date: YYMMDD OK?: OK: comparison OK, ERR: error ERR: If ERR, the reason for error: F: Not all files exist R: Number of records don't match T: Timestamps don't match V: Versions don't match G: Generation dates error S: Special conditions not met (if applicable) Rx: Number of records in file x Vx: Version of file x Gx: Generation time Ix: Ingestion time Processing policy: - CHECK FILES - CHECK NUMBER OF RECORDS - CHECK TIMESTAMPS - DON'T CHECK FILE VERSIONS - CHECK IF GENERATION DATES ARE WITHIN 90 DAYS - CHECK IF DATASET 1 IS THE OLDEST ONE

16 Example: EDI – AE datasets
Date OK? ERR R R V1 V2 G G I I2 ERR MORE THAN ONE FILE WITHIN ONE DAY *** ERR MORE THAN ONE FILE WITHIN ONE DAY *** ERR MORE THAN ONE FILE WITHIN ONE DAY *** ERR MORE THAN ONE FILE WITHIN ONE DAY *** ERR MORE THAN ONE FILE WITHIN ONE DAY *** ERR MORE THAN ONE FILE WITHIN ONE DAY *** ERR F T17:10:37Z T09:37:55Z ERR MORE THAN ONE FILE WITHIN ONE DAY *** ERR MORE THAN ONE FILE WITHIN ONE DAY *** ERR MORE THAN ONE FILE WITHIN ONE DAY *** ERR MORE THAN ONE FILE WITHIN ONE DAY *** ERR MORE THAN ONE FILE WITHIN ONE DAY *** ERR MORE THAN ONE FILE WITHIN ONE DAY *** ERR MORE THAN ONE FILE WITHIN ONE DAY *** ERR MORE THAN ONE FILE WITHIN ONE DAY *** ERR G T14:32:39Z T18:52:53Z T08:16:49Z T13:52:46Z ERR F T15:35:31Z T18:38:32Z ERR F T14:12:32Z T09:14:23Z ERR F T14:13:10Z T09:14:52Z ERR F T14:13:48Z T09:15:05Z

17 Example: EDI – AE datasets
OK T15:08:51Z T16:10:06Z T16:25:56Z T10:35:30Z ERR MORE THAN ONE FILE WITHIN ONE DAY *** OK T15:09:23Z T16:10:40Z T16:26:06Z T10:35:34Z C1_CP_EDI_AE_ _v27.cef: T00:00:00.000Z / T23:59:57.048Z C1_CP_EDI_AE_ _v27.cef.gz                    T23:59:57.049Z / T23:59:59.850Z

18 EGD - Duplicate Time Stamps

19 EDI Delivery/Ingestion Activity
The plots are regenerated daily around mid-night Monthly and 6-month plots Top two panels are taken from database Top: Number of files ingested into the database 2nd from top: average time used for one file to validate/add into the database Bottom five shows an instantaneous situation at the time of plot production 3rd: Number of files failed validation: e.g. wrong version number 4th and 5th: number of CEF and nn-CEF files in the delivery area 6th and 7th: number of CEF and non-CEF files waiting for validation

20 Status of File Transfer to CSA
File transfer from CAA to CSA has been automated The two database are now identical New files on the CAA will be transferred to the CSA within a day


Download ppt "Status Report of EDI on the CAA"

Similar presentations


Ads by Google