Beyond geometrical overlap: a Dosimetrical Evaluation of automated volumes Adaptation (DEA) in head and neck replanning  Gian Carlo Mattiucci, Luca Boldrini,

Similar presentations


Presentation on theme: "Beyond geometrical overlap: a Dosimetrical Evaluation of automated volumes Adaptation (DEA) in head and neck replanning  Gian Carlo Mattiucci, Luca Boldrini,"— Presentation transcript:

1 Beyond geometrical overlap: a Dosimetrical Evaluation of automated volumes Adaptation (DEA) in head and neck replanning  Gian Carlo Mattiucci, Luca Boldrini, Lorenzo Placidi, Luigi Azario, Nicola Dinapoli, Giuditta Chiloiro, Danilo Pasini, Danila Piccari, Maria Antonietta Gambacorta, Mario Balducci, Giovanna Mantini, Vincenzo Valentini  Technical Innovations and Patient Support in Radiation Oncology   Volume 3, Pages 1-6 (September 2017) DOI: /j.tipsro Copyright © 2017 The Authors Terms and Conditions

2 Fig. 1 IMRT plan realization and evaluation of plan A and B on benchmark PTV C. Technical Innovations and Patient Support in Radiation Oncology  2017 3, 1-6DOI: ( /j.tipsro ) Copyright © 2017 The Authors Terms and Conditions

3 Fig. 2 Correlation between the DSI and mHD distance comparing the PTV C-PTV A (■) and PTV C-PTV B (○) overlap. Linear correlations between the DSI and mHD comparing PTV C-PTV A and PTV C-PTV B result, respectively, in a R2=0.84 and R2=0.82. Technical Innovations and Patient Support in Radiation Oncology  2017 3, 1-6DOI: ( /j.tipsro ) Copyright © 2017 The Authors Terms and Conditions

4 Fig. 3 Correlation between the DSI and PTV volume reduction (cc) comparing PTV C and PTV A (■) and between PTV C and PTV B (○). Technical Innovations and Patient Support in Radiation Oncology  2017 3, 1-6DOI: ( /j.tipsro ) Copyright © 2017 The Authors Terms and Conditions

5 Fig. 4 Correlation between the DSI and PTV C V95% coverage difference for Plan A (■) and for Plan B (○). Technical Innovations and Patient Support in Radiation Oncology  2017 3, 1-6DOI: ( /j.tipsro ) Copyright © 2017 The Authors Terms and Conditions

6 Fig. 5 Correlation between the DSI and PTV C D99% coverage difference for Plan A (■) and for Plan B (○). Technical Innovations and Patient Support in Radiation Oncology  2017 3, 1-6DOI: ( /j.tipsro ) Copyright © 2017 The Authors Terms and Conditions

7 Fig. 6 PTV dose coverage (isodose levels: 75–95%) for different plans. Left: plan A, middle: plan B, right: plan C (benchmark) on benchmark structure set. Technical Innovations and Patient Support in Radiation Oncology  2017 3, 1-6DOI: ( /j.tipsro ) Copyright © 2017 The Authors Terms and Conditions