Presentation is loading. Please wait.

Presentation is loading. Please wait.

SILICON PIXELS DETECTOR

Similar presentations


Presentation on theme: "SILICON PIXELS DETECTOR"— Presentation transcript:

1 SILICON PIXELS DETECTOR
FORCED CONVECTION COOLING TEST COOLING PRINCIPLE Vittore Carassiti, Marco Statera, Ferruccio Petrucci, Luca Landi, Stefano Squerzanti, Stefano Chiozzi, Manuel Bolognesi, Michele Melchiorri, Claudio Padoan CERN , 11/12/2007

2 Vittore Carassiti - INFN FE
SUMMARY DESIGN CONCEPT DESIGN DEVELOPMENT TEST SETUP PEOPLE INVOLVED NA62 GTK Meeting , CERN Vittore Carassiti - INFN FE CERN , 11/12/2007

3 Vittore Carassiti - INFN FE
DESIGN CONCEPT THE DESIGN OF THE DETECTOR REQUIRES TO MINIMIZE THE MATERIAL BUDGET THE COOLING SYSTEM CONCEPT DESIGN FOLLOWS THE SAME REQUIREMENT NA62 GTK Meeting , CERN Vittore Carassiti - INFN FE CERN , 11/12/2007

4 STARTING DESIGN CONCEPT - 1
Nr ELEMENT THERMAL CONDUCTIVITY (W/mK) THICKNESS (mm) 1 K1100 CARBON FIBER 1000 0,1 2 THERMAL COMPOUND 8,7* 0,2 3 PIXELS 205 4 BUMPS 0,4** 0,01 5 SENSORS COOLING PLATE HEAT FLUX CONDUCTIVE COOLING THIN COOLING PLATE + COOLING CIRCUIT SURROUNDING THE DETECTOR NA62 GTK Meeting , CERN Vittore Carassiti - INFN FE

5 STARTING DESIGN CONCEPT -2
Cooling system BOUNDARY CONDITIONS SURFACE COLLECTING THE POWER SCP = 27 x60 mm^2 HEAT FLUX UNIFORM HF = 2 W/cm^2 = 2E+04 W/m^2 Supporting plate Heat flux TEMPERATURE DISTRIBUTION ON THE DETECTOR NOT UNIFORM (>30°C) NA62 GTK Meeting , CERN Vittore Carassiti - INFN FE

6 MOVING TOWARD A DIFFERENT COOLING CONCEPT - 1
CONVECTIVE COOLING USING A NITROGEN GAS FLOW AND THIN FLAT WALLS CONVECTION COEFFICENT = 55 W/m^2K MAX DETECTOR TEMP = 2,6 °C GOOD TEMPERATURE UNIFORMITY COOLING FLOW NA62 GTK Meeting , CERN Vittore Carassiti - INFN FE

7 MOVING TOWARD A DIFFERENT COOLING CONCEPT - 2
MAX DISPL = 1,3 mm MAX STRESS = 700 Mpa WALL THICKNESS = 0,2 mm PRESSURE INSIDE = 0,1 MPa THE FLAT WALL NEEDS A THICKNESS > 0,2 mm TOO MUCH MATERIAL !! NA62 GTK Meeting , CERN Vittore Carassiti - INFN FE

8 Vittore Carassiti - INFN FE
THE DEVELOPED DESIGN – 1 SHARING THE JOBS : CYLINDRICAL WALLS SUPPORTING THE PRESSURE FLAT WALLS DEFINING THE FLOW CROSS SECTION CHOSEN MATERIAL = KAPTON TYPE H THINNER THICKNESSES REQUIRED : CYLINDRICAL WALL = 40 MICRONS FLAT WALL = 10 MICRONS ROUND WALL KAPTON RADIATION LENGTH = 28,6 cm COOLING VESSEL RADIATION LENGTH = 0,035% Xo FLAT WALL NA62 GTK Meeting , CERN Vittore Carassiti - INFN FE

9 Vittore Carassiti - INFN FE
THE DEVELOPED DESIGN - 2 MAKING THE PARTS ALL PARTS MADE BY FERRARA WORKSHOP NA62 GTK Meeting , CERN Vittore Carassiti - INFN FE CERN , 11/12/2007

10 TESTS @ ROOM TEMPERATURE
THE DEVELOPED DESIGN – 3 ROOM TEMPERATURE THE FOLLOWING TESTS HAVE BEEN DONE : KAPTON CREEP KAPTON FAILURE PRESSURE QUALITY OF THE JOINT KAPTON-RESIN-ALUMINUM NA62 GTK Meeting , CERN Vittore Carassiti - INFN FE CERN , 11/12/2007

11 TEST 1 -BONDING ALUMINUM FRAME & KAPTON FOIL
PREPARATION OF THE JOINTS : ALUMINUM JOINT ABRADED AND DEGREASED KAPTON JOINT LIGHTLY ABRADED AND DEGREASED CURING TIME : 16 40°C NA62 GTK Meeting , CERN Vittore Carassiti - INFN FE CERN , 11/12/2007

12 TEST 2 - BONDING ALUMINUM FRAME & KAPTON FOIL
NA62 GTK Meeting , CERN Vittore Carassiti - INFN FE CERN , 11/12/2007

13 TEST 3 - KAPTON CREEP TEST
Working pressure Wp = 1 bar Test pressure Tp = 2Wp = 2 bar AFTER TWO Tp NO EVIDENCE OF CREEP NA62 GTK Meeting , CERN Vittore Carassiti - INFN FE CERN , 11/12/2007

14 TEST 4 - KAPTON FAILURE PRESSURE
STRESS ON THE VESSEL BOUNDARY CONDITIONS Pi = 0,1 Mpa (inner pressure) Pe = 0 (outher pressure) s = 5E-05 m (wall thickness) Di = 47E-03 m (inner diameter) FAILURE PRESSURE CALCULATION EQUIVALENT TENSILE STRESS (Guest criterion) NA62 GTK Meeting , CERN Vittore Carassiti - INFN FE CERN , 11/12/2007

15 TEST 5 - JOINT KAPTON-RESIN-ALUMINUM
LENGTH OF THE OVERLAP CALCULATION NA62 GTK Meeting , CERN Vittore Carassiti - INFN FE CERN , 11/12/2007

16 TEST BENCH & READUT SYSTEM
VACUUM POWER & TEMPERATURES FLOW RATE NA62 GTK Meeting , CERN Vittore Carassiti - INFN FE CERN , 11/12/2007

17 OPTIMIZING THE GAS INJECTION -1
Injection channels : Share the flow rate & avoid the temperature drop on the inner edge of the detector lateral channels : the flow is injected cooled until the exit NA62 GTK Meeting , CERN Vittore Carassiti - INFN FE CERN , 11/12/2007

18 OPTIMIZING THE GAS INJECTION - 2
SILICON WINDOW DETECTOR MOCK UP & DISTRIBUTING CHANNELS THERMO-CAMERA NA62 GTK Meeting , CERN Vittore Carassiti - INFN FE CERN , 11/12/2007

19 COMPARING THE THERMOCAMERA RESULTS WITH THE THERMAL MODEL
THERMOCAMERA IMAGE NA62 GTK Meeting , CERN Vittore Carassiti - INFN FE CERN , 11/12/2007

20 THE TESTED PROTOTYPE REALIZATION
THE PROTOTYPE ROUND WALLS = 40 microns FLAT WALLS = 10 microns CROSS SECTION = 8x46 mm^2 NA62 GTK Meeting , CERN Vittore Carassiti - INFN FE CERN , 11/12/2007

21 TESTING THE WIRES STABILITY UNDER GAS FLOW
(6 groups of 10 wires) NITROGEN FLOW RATE RANGE : FROM 0 TO 12 m^3/h (1,5 the nominal rate) ; THE WIRES ARE STEADY NA62 GTK Meeting , CERN Vittore Carassiti - INFN FE CERN , 11/12/2007

22 Design, simulation, tests, development & construction
Vittore CARASSITI (mech. service) Marco STATERA (vacuum & cryo service) Manuel BOLOGNESI (electr. service) Stefano CHIOZZI (electr. service) Angelo COTTA RAMUSINO (electr. service) Luca LANDI (mech. service) Roberto MALAGUTI (electr. service) Michele MELCHIORRI (mech. service) Claudio PADOAN (electr. service) Stefano SQUERZANTI (mech. service) NA62 GTK Meeting , CERN CERN , 11/12/2007