1 First Look at Housekeeping Data
The goal Demonstrate the ability to correlate housekeeping data with “science” data Generate a list of distributions to be monitored for the LAT tests during I&T Improve and tailor the system to match ISOC needs Today’s Test Correlate hit multiplicity in a layer with temperature from CAL and TKR sensors The method Verify that temperature values agree with expectation Correlate temperature with layers in the TKR

2 Location of TKR sensors
There are 2 sensors attached to each of the 8 TKR cables In the diagram above we only highlighted 8 of the 16 sensors

3 Location of temperature sensor in TKR

4 Location of CAL sensors
Thermistor

5 What do we expect for 2 towers?
Grid temperature is close to that of CAL OK Bottom sensor of TKR could be a few degrees above the grid temperature Top sensor of TKR should be at a higher temperature than bottom sensor Oops, this is not what we see. See next slides TKR top sensors TKR bottom sensors CAL sensor

6 CAL temperature for Towers 0 and 4
Sensor 0 is not used Sensor 0 is not used Time Time Temperature Temperature Sensor 1 only Sensor 1 only Temperature is uniform within 0.50C Time Time

7 TKR temperature for Towers 0 and 4
Temperature is uniform within 0.50C Time Time Temperature Temperature Puzzle: Top sensor temperature is systematically higher than that of the lower sensor Time Time

8 What’s up with the discrepancy?
There are three reasons why the TKR top could be at lower temperature than TKR bottom? Error in data analysis code that plots the distributions Xin already checked this is not the case Variations as function of time Error in mapping the thermistor when reading it out and before loading into the database Error in loading the values in the ISOC database Jim Panetta is checked that this is not the case Expectations based on current configuration are actually wrong Will ask Martin Nordby about that Could be an issue in converting values in the TEM Will ask Mike/Leonid about it

9 Monitor Peak Temperature
TKR Cable Number Tower 4 3 2 1 4 Y 5 6 7 X Tower 0 3 2 Expect these 4 values to be higher than the other ones 4 1 5 6 7 These should be monitored as we assemble more towers

10 Science Data vs. Housekeeping Data
From Xin… Temperature Hit multiplicity Temperature Hit multiplicity Tower 0, bottom layer Tower 0, top layer Time Time Temperature Temperature Hit multiplicity Hit multiplicity Tower 4, bottom layer Tower 4, top layer Time Time