Presentation is loading. Please wait.

Presentation is loading. Please wait.

Protection Specialist

Similar presentations


Presentation on theme: "Protection Specialist"— Presentation transcript:

1 Protection Specialist
SC B5 - Protection and Automation Report to the Canadian National Committee of CIGRÉ 2011 Simon R. Chano Protection Specialist Hydro Québec TransÉnergie 2, Complexe Desjardins, tour Est 9ième étage C.P Montréal, QC H5B 1H7

2 SC B5- STRATEGIC ACTIVITIES
Synthesizing and disseminating state-of-the-art practices and developing recommendations For the progress of engineering of power system protection, automation, monitoring and metering Simon R. Chano, Hydro Québec TransÉnergie

3 Simon R. Chano, Hydro Québec TransÉnergie
SC B5 Thematic Groups TG51 V. Leitoff (FR) TG52 S. Chano (CA) TG53 R. Adams (UK) TG54 I. Mesmaeker (CH) Substation Automation and Remote Control Protection & Monitoring of Main Plant and Circuits Monitoring, Metering, Recording and Overall Power System Protection Tutorials Simon R. Chano, Hydro Québec TransÉnergie

4 Simon R. Chano, Hydro Québec TransÉnergie
Substation Automation IEC – Widespread application and acceptance Documentation – Deficiencies in reference material Training – Lack of reference tutorials Testing – New requirements for commissioning and maintenance Engineering tools – The key for a efficient IEC implementation The Process Bus – The technology is mature for implementation in real projects. Current Issues Working Groups WG B5.39: Documentation Requirements for DSAS WG B5.42: Experience Concerning Availability and Reliability WG B5.45: Acceptance, Commissioning and Field Testing WG B5.40: Education and Qualification of Engineers in P & C Simon R. Chano, Hydro Québec TransÉnergie

5 Simon R. Chano, Hydro Québec TransÉnergie
Protection and Monitoring Current Issues FACTS & HVDC – Requirements and impacts on AC protection Special equipments – Protection requirements New Sensors – Modeling and transients Training – Guide lines for digital protection application Working Groups WG B5-23: Short Circuit Protection of Mixed Conductor Networks JWG B5/B4/C4-25: Impact of HVDC Station on AC Protection WG B5-37: Protection, Monitoring and Control of Shunt Reactors WG B5-24: Transients on V & I Digital Acquisition Chain WG B5-27: Benefits of Standardized Protection Schemes WG B5-36: Application for Protection Schemes Based on IEC61850 WG B5.44: Protection Schemes for Special Transformers Simon R. Chano, Hydro Québec TransÉnergie

6 Simon R. Chano, Hydro Québec TransÉnergie
Network Requirements Current Issues WAMPS – New requirements and impacts Communication – Coordination of communication performance and protection requirements. Information Systems – Protection management, automated fault analysis, asset management. Network of the future – Local and wide area Coordination of protection and control. Working Groups WG B5-14: Wide Area Protection & Control Technologies JWG B5/D2-30: Communications for Protection & WAMPS WG B5-31: Management of Protection Settings WG B5.41: Metering Systems for Billing Purposes WG B5.43: Coordination of P & C of Future Network Simon R. Chano, Hydro Québec TransÉnergie

7 SC B5 Next Colloquium and Future meetings
Switzerland 2011 – Preferential Subjects PS1 - IEC 61850: Which tools for which user PS2 - Protection of Hybrid Line/Cable PS3 - Performance of Protection Systems. Whilst the Network is under Stress France 2012 – Preferential Subjects PS1 - Coordination of Protection and Control for the Network of the Future PS2 - Use of remote access for protection and automation systems - application and developments Brazil 2013 • With local Protection & Automation Symposium Simon R. Chano, Hydro Québec TransÉnergie

8 Simon R. Chano, Hydro Québec TransÉnergie
Web site SC address : web site is Pour information additionnelle /For additional information, me contacter / you can contact me: Simon R. Chano, Hydro Québec TransÉnergie


Download ppt "Protection Specialist"

Similar presentations


Ads by Google