Presentation is loading. Please wait.

Presentation is loading. Please wait.

X-Ray PHA Data Acquisition - Lynx Tool (Ch. Veth) -

Similar presentations


Presentation on theme: "X-Ray PHA Data Acquisition - Lynx Tool (Ch. Veth) -"— Presentation transcript:

1 X-Ray PHA Data Acquisition - Lynx Tool (Ch. Veth) -
● start Lynx Tool (lynx.exe) under ● Shot synchronized DAQ ● Lynx C++ software using Canberra toolkit routines for Lynx control & data transfer ● Lynx data (ascii, 40 spectra (default) temporarily saved (default) in c:\lynxpha ● rawfiles manually copied into afs at end of the day: /afs/ipp/u/phaspo/pha/rawfiles ● file names: Lynx_<shot-nr>_MSSdata_acq.txt ● add additional parameters from aug_pha_parm.txt and store data in /afs/augd/rawfiles/PHB (manually by idl tool) A. Weller, Garching 2011

2 Lynx (Digital Signal Analyzer)
SIO HOTLINK (2x2 ch latching count.) PHB Ethernet gigepc.aug.ipp.mpg.de user: phaspo Lynx Tool (C++) data (shot synchronized, default path): c:\lynxpha\ Lynx_<shot-nr>_MSSdata_acq.txt sxaug20.aug.ipp-garching.mpg.de user: phaspo data analysis tool (IDL, offline) merge data tool (IDL, offline) manual corr. (few cases) manual transfer afs: user: phaspo path: afs/ipp/u/phaspo/pha/rawfiles data files: Lynx_<shot-nr>_MSSdata_acq.txt add. parameter file: aug_pha_parm.txt manual manual afs: path: afs/augd/rawfiles/PHB/<shot-nr(0:1)> data files: <shot-nr> A. Weller, Garching 2011

3 afs/ipp/u/phaspo/pha/rawfiles/Lynx_27392_MSSdata_acq.txt afs/ipp/u/phaspo/pha/rawfiles/aug_pha_parm.txt Rise Time(uS): 0.2 Flat Top Time (uS): 0.2 Fast Disc(%): 8 Preamp- Type: TRP PUR/LTC Mode: On Preset Mode: Real Preset time(s): Number of spectra: 40 Total record time(s): Fine Gain: 1 LLD(%): 1.8 ULD(%): 100 LT Trim: 250 Coarse Gain: 4 Conversion Gain: 1024 TRP Inhibit(uS): 20 High Voltage: High Voltage Polarity: Negative Calibration Energy Offset(keV): E-02 Calibration Energy Slope(keV): E-02 Calibration Energy Quad(keV): 0 Spectrum: 1 Start time: 0:0:0.0 Live time (uS): Real time (uS): Status: Idle Time Preset reached Spectrum: channel counts 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 0 ; start shot ; thickness Be-filter (Micron) ; aperture diameter (mm) ; start shot ; aperture diameter (mm) ; start shot ; aperture diameter (mm) ; start shot ; aperture diameter (mm) ; start shot ; aperture diameter (mm) ; start shot ; aperture diameter (mm) ; start shot ; thickness Be-filter (Micron) ; start shot ; aperture diameter (mm) ; start shot ; start shot ; thickness Be-filter (Micron) ; start shot ; start shot ; start shot ; aperture diameter (mm) A. Weller, Garching 2011

4 additional parameters
afs/ipp/u/augd/rawfiles/PHB/27/27392 aperture: 2.60 filter: thbesdd: thsia: Rise Time(uS): 0.2 Flat Top Time (uS): 0.2 Fast Disc(%): 8 Preamp- Type: TRP PUR/LTC Mode: On Preset Mode: Real Preset time(s): Number of spectra: 40 Total record time(s): Fine Gain: 1 LLD(%): 1.8 ULD(%): 100 LT Trim: 250 Coarse Gain: 4 Conversion Gain: 1024 TRP Inhibit(uS): 20 High Voltage: High Voltage Polarity: Negative Calibration Energy Offset(keV): E-02 Calibration Energy Slope(keV): E-02 Calibration Energy Quad(keV): 0 Spectrum: 1 Start time: 0:0:0.0 Live time (uS): Real time (uS): Status: Idle Time Preset reached Spectrum: channel counts 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 0 additional parameters A. Weller, Garching 2011


Download ppt "X-Ray PHA Data Acquisition - Lynx Tool (Ch. Veth) -"

Similar presentations


Ads by Google