PNMT - GENERAL PASOLINK NETWORK MANAGEMENT TERMINAL (PNMT) IS A MOBILE TERMINAL CONSISTING OF A PORTABLE COMPUTER WITH A SIMPLIFIED VERSION OF THE PASOLINK.

Similar presentations


Presentation on theme: "PNMT - GENERAL PASOLINK NETWORK MANAGEMENT TERMINAL (PNMT) IS A MOBILE TERMINAL CONSISTING OF A PORTABLE COMPUTER WITH A SIMPLIFIED VERSION OF THE PASOLINK."— Presentation transcript:

1 PNMT - GENERAL PASOLINK NETWORK MANAGEMENT TERMINAL (PNMT) IS A MOBILE TERMINAL CONSISTING OF A PORTABLE COMPUTER WITH A SIMPLIFIED VERSION OF THE PASOLINK NETWORK MANAGEMENT SOFTWARE DEVELOPED FOR MANAGEMENT OF NEC PASOLINK SERIES SHORT HAUL RADIO TRANSMISSION NETWORK. PNMT IS DESIGNED AS AN ONSITE MAINTENANCE TOOL TO BE USED BY THE FIELD ENGINEERS AND TECHNICIANS. IT CONNECTS DIRECTLY TO THE LA PORT OF THE PASOLINK IDU. PNMT CAN BE USED TO MONITOR LOCAL / REMOTE EQUIPMENT STATUS AND PROVIDES CONTROL CAPABILITIES SIMILAR TO THOSE AVAILABLE IN PNMS. PNMT IS ALSO USED TO DOWN LOAD THE SYSTEM AND CONFIGURATION FILES TO THE PM CARD AND UPGRADE THE SOFTWARE IN THE IDU WHEN CONNECTED TO AN IDU PNMT CAN MONITOR NOT ONLY THE LOCAL EQUIPMENT BUT ANY REMOTE NETWORK ELEMENT UNDER THE CONTROL OF THE CENTRAL PM CARD. TO USE THE PNMT, PM CARD SHOULD BE MOUNTED IN THE IDUs. PNMT

2 FUNCTIONS MICROSOFT WINDOWS 98/NT/200/XP WORKSTATION GRAPHICAL USER INTERFACE ONE HOP LINK DISPLAY ON THE PNMT SCREEN COMMUNICATE WITH REMOTE PM CARDS ON THE SAME NETWORK COLLECTS ALARM AND STATUS INFORMATION FROM THE LOCAL AND REMOTE PM CARDS TRANSMISSION EQUIPMENT CONTROL VIA LOCAL AND REMOTE PM CARDS SEVERAL LEVELS OF LOGIN / LOGOUT EVENT LOGGING WINDOW PERFORMANCE MONITORING FUNCTION WINDOW LOCAL / REMOTE EQUIPMENT CONTROL FUNCTION LOCAL/REMOTE PM CARD CONFIGURATION MANAGEMENT LOCAL/REMOTE UP GRADING OF APPLICATION SOFTWARE PNMT

3 PNMT COMMUNICATION INTERFACE
COMMUNICATION BETWEEN THE PNMT AND THE RADIO NETWORK EQUIPMENT CAN BE : VIA THE LA PORT OF THE LOCAL PASOLINK EQUIPMENT VIA THE DIGITAL SERVICE CHANNEL DSC TO A REMOTE PASOLINK EQUIPMENT LA PORT IS LOCATED ON THE FRONT OF THE EQUIPMENT AND CONSISTS OF A DB15 CONNECTOR. LA PORT CONNECT THE PM CARD IN THE IDU VIA A SERIAL CABLE TO THE RELEVANT COMMUNICATION PORT OF THE PNMT COMPUTER. PROPERTIES OF THE LA PORT ARE AS FOLLOWS: PORT CONFIGURATION RS-232 CONNECTOR TYPE D-SUB 15 (FEMALE) BITS PER SECOND RATE UP TO 19200 LA PORT PNMT

4 HARDWARE/SOFTWARE CONFIGURATION
RECOMMENDED PNMT MOBILE PC CONFIGURATION LAPTOP PC WITH TFT DISPLAY (IBM COMPATIBLE) CPU: PENTIUM-400 OR HIGHER RAM: 128 MB OR MORE HDD: 2 GB OR MORE FDD: 3.5INCH CD-ROM: 8 x OR HIGHER INTEGRATED SOUND CARD AND SPEAKER SOFTWARE CONFIGURATION ALL STRUCTURED AND MODULAR PROGRAMS USED IN PNMT ARE RESIDENT IN THE HARD-DISK AND RAM OF THE PERSONAL COMPUTER. THE WINDOWS OPERATING SYSTEM IS EMPLOYED WHICH IS CAPABLE OF MULTITASK PROCESSING. THE PNMT SOFTWARE BASICALLY CONSISTS OF TWO PARTS, THE OPERATING SYSTEM AND THE APPLICATION PROGRAM OPERATING SYSTEM WINDOWS 98 (ENGLISH VERSION) WINDOWS NT WORKSTATION Ver 4.0 (ENGLISH VERSION) WITH SP 6.0 OR HIGHER WINDOWS 2000 (ENGLISH VERSION) WITH SP3 OR HIGHER WINDOWS XP (ENGLISH VERSION) WITH SP1 OR HIGHER APPLICATION PROGRAM NEC PNMT SOFTWARE IE 5.0 OR HIGHER ACROBAT READER PNMT

5 START UP CONNECT THE PNMT PC COM1 PORT AND THE PASOLINK IDU LA PORT USING A RS232C CABLE PREPARATION From the Control Panel select Phone and Modem Options. Add a Standard bps Modem and assign it to the COM1 port ( or the COM port to be used) DOUBLE CLICK ON THE PNMT SHORTCUT ICON ON THE DESKTOP OR CLICK ON START>>PROGRAM>>PNMT>>PNMT Create a Dial-up connection using the above standard modem and name it as “pnmt” Install the NEC PNMT software See PNMT Install Manual for details PNMT PROGRAM STARTUP AND TRIES TO GET CONNECTED TO PASOLINK EQUIPMENT USING THE DIAL-UP CONNECTION “PNMT” AFTER CONNECTING TO THE PASOLINK EQUIPMENT TRIES TO ACQUIRE DATA FROM THE LOCAL EQUIPMENT AND THE REMOTE EQUIPMENT TO DISPLAY ON THE LINK SUMMARY WINDOW PNMT

6 SHUT DOWN IF YOU HAVE NOT LOGIN FIRST THE EXIT MENU CANNOT BE SELECTED. TO EXIT THE PNMT PROGRAM CLICK ON EXIT IN THE SYSTEM DROPDOWN MENU AND CLICK YES. IN THE DIALOG BOX THAT OPENS CLICK YES THE SCREEN INDICATES NOW PNMT SHUTDOWN. IT WILL TAKE FEW MINUTES TO SHUTDOWN PNMT

7 PNMT MAIN SCREEN PNMT MAIN SCREEN IS SPLIT EVENLY TO DISPLAY THE DATA FROM THE TWO NEs IN THE HOP. PNMT WINDOW MENU BAR COMMON TOOL BAR LINK SUMMARY WINDOW NE-SPECIFIC MENU ITEMS BLOCK DIAGRAM NE-SPECIFIC DATA CLICK ON THE ARROW ICONS IN THE MIDDLE OF THE SCREEN TO EXPAND THE LEFT OR RIGHT DATA FIELD. CLICKING ON THE BLOCK WILL RETURN THE ORIGINAL SPLIT SCREEN. TAB SELECTION FOR OTHER EQUIPMENT VIEWS PNMT

8 PNMT MAIN SCREEN PNMT COMMON MENU BAR
COMMON MENU BAR OF THE PNMT WINDOW PRESENTS THE SYSTEM AND HELP MENU ITEMS. EACH MENU ITEM HAVE A DROP DOWN MENU SHOWING THE OPTIONS AVAILABLE. COMMON TOOL BAR COMMON TOOL BAR OF THE PNMT WINDOW HOLDS THE ICONS OF THE FREQUENTLY USED MENU ITEMS LINK SUMMARY WINDOW LINK SUMMARY WINDOW SHOWS THE SELECTED NETWORK ELEMENT (NE) AND ITS OPPOSITE NE AS A LINK (HOP). THE SELECTED NE IS SHOWN ON THE LEFT HAND SIDE WINDOW AND THE OPPOSITE NE ON THE RIGHT HAND SIDE WINDOW OF THE LINK SUMMARY WINDOW. IT SHOWS GRAPHICALLY THE STATUS OF THE PASOLINK EQUIPMENT IN BLOCK DIAGRAM FORM. NE-SPECIFIC PARAMETERS AND NE-SPECIFIC MENU ITEMS ARE ALSO SHOWN IN THIS WINDOW NE SPECIFIC DATA : TRANSMIT ATTENUATION NE SPECIFIC DATA ARE SHOWN IN SEVERAL DATA WINDOWS SELECTED BY THE TABS AT THE BOTTOM OF THE WINDOW OR BY CLICKING THE EQUIPMENT SYMBOLS IN THE BLOCK DIAGRAM. DATA DISPLAYED DEPENDS ON THE EQUIPMENT TYPE (PASOLINK +, V3, V4, ETC.) NE SPECIFIC MENU ITEMS: EQUIPMENT CONFIGURATION EQUIPMENT SETUP MAINTENANCE LINK PERFORMANCE MONITOR EVENT LOG TAB SELECTION DETAILED MONITORING STATUS AND ALARMS OF EACH MAIN UNIT IN THE PASOLINK EQUIPMENT (ODU, IDU, AUX I/P AND PMC) CAN BE VIEWED BY CLICKING ON THE RELEVANT TAB. NE BLOCK DIAGRAM: STATUS OF EACH MAIN UNIT IN THE PASOLINK EQUIPMENT (ODU, IDU, AUX I/P AND PMC) ARE SHOWN IN THE BLOCK DIAGRAM AS SYMBOLS. WHEN ANY SYMBOL IS CLICKED THE RELATED EQUIPMENT WINDOW OPEN AND SHOWS THE DETAILS OF ALARM AND STATUS DETAILS AND OTHER PARAMETERS, PNMT

9 PNMT WINDOW MENU ITEMS PNMT SYSTEM REFRESH HELP HELP
DISPLAY A LIST OF PNMT MANUALS IN PDF FILE FORMAT ABOUT DISPLAY THE PNMT VERSION NUMBER THIS FUNCTION ENABLES PNMT TO ACQUIRE ALL STATUS MANUALLY AND TO UPDATE EQUIPMENT INFORMATION THIS FUNCTION OPEN THE LOGIN/LOGOUT WINDOW TO ENTER THE USER NAME AND PASSWORD. THIS FUNCTION OPEN THE PASSWORD CHANGE WINDOW LOGIN / LOGOUT CHANGE PASSWORD THIS FUNCTION IS USED TO ENABLE/DISABLE THE BUZZER FUNCTION AND DEFINE THE BUZZER SOUND ALARM BUZZER CONNECT THIS FUNCTION IS USED TO DISPLAY THE SUMMARY LIST OF THE NETWORK ELEMENTS IN THE NETWORK EXIT THIS FUNCTION IS USED TO CLOSE THE PNMT PROGRAM PNMT

10 LINK PERFORMANCE MONITOR
NE SPECIFIC MENU ITEMS CONFIGURATION EVENT LOG LINK PERFORMANCE MONITOR THIS FUNCTION OPEN THE G826 LINK PERFORMANCE INFORMATION WINDOW. THIS FUNCTION UPLOAD THE EVENT LOG INFORMATION FROM THE SELECTED NE AND DISPLAY THE INFORMATION IN EVENT LOG WINDOW FREQUENCY SETTING TX POWER CONT BIT RATE EQUIPMENT SETUP SYSTEM CONFIG MAINTENANCE LAN SETTING FRAME ID BER THRESHOLD AIS SEND ON/OFF MAINT MODE ON/OFF AIS RCVD ON/OFF TX MUTE ON/OFF SC4 & SC5 SETTING CW ON/OFF NE NAME BER AIS ON/OFF NOTE SWITCHOVER (1+1) PNMT

11 PNMT LOGIN / LOGOUT & EXIT
CLICK ON SYSTEM IN THE MENU BAR AND THEN CLICK ON LOGIN/LOGOUT IN THE DROP DOWN MENU TO OPEN THE LOGIN/LOGOUT WINDOW TO LOGIN SELECT LOGIN IN THE LOGIN/LOGOUT WINDOW. ENTER THE USER NAME ACCORDING TO THE PRIVILEGES AND THE PASSWORD. CLICK OK TO LOGIN TO PROTECT THE NETWORK AND NETWORK MANAGEMENT SYSTEM FROM UNAUTHORIZED ACCESS OR MODIFICATIONS, FIVE LEVELS OF USERS ARE DEFINED WITH DIFFERENT PRIVILEGES. THE FUNCTIONS AVAILABLE DEPENDS ON THE USER ACCESS LEVEL, (SEE THE TABLE NEXT PAGE) TO LOGOUT SELECT LOGOUT IN THE LOGIN/LOGOUT WINDOW AND CLICK OK. PNMT

12 USER NAMES & PRIVILEGES
Category Item Monitor(0) User(1) Local(2) Remote(3) Admin(4) MENU-SYSTEM DATE TIME ALARM BUZZER DOWNLOAD PMC PROGRAM FILE CONNECT (REMOTE LOGIN) MENU-CONFIGURATION FILE DOWNLOAD FILE/ UPLOAD FILE UPDATE IDU WS ALARM INHIBIT (OPTION) CH (LB1) / CH(LB2) CH (ALARM INHIBIT) MAINTENANCE MAINTENANCE MODE TX MUTE CW BER AIS SWITCH OVER (1+1) EQUIPMENT CONFIGURATION FREQUENCY PLAN (CH) TX ATTENUATION BIT RATE FRAME ID BER THRESHOLD AIS RCVD ALARM ON/OFF AIS SEND ALARM ON/OFF SC4 AND SC5 PASOLINK NAME NOTE AUX I/O OPTO ITEM TYPE OPTO NAME RELAY NAME RELAY CONTROL PMON PMON THRESHOLD PMON DATA RESET SAVE TO DISK LOGGING PMC RESET PNMT

13 OVERALL WINDOW PNMT OVERALL WINDOW FOR (1+1) CONFIGURATION
OVERALL WINDOW DISPLAY THE FOLLOWING INFORMATION: TX ATTENUATION USED TX AND RX FREQUENCIES USED BIT RATE USED MAINTENANCE MODE ON OR OFF STATUS. IF ON, BACK GROUND COLOR CHANGE TO YELLOW. SELECTED TX AND RX CHANNEL IN (1+1) HOT STANDBY CONFIGURATION FRAME ID USED ODU TYPE USED V3 OR V4 CLICK THE OVERALL TAB TO DISPLAY THE OVERALL WINDOW TX POWER CONTROL USED PNMT

14 ODU WINDOW CLICK THE ODU SYMBOL IN THE BLOCK DIAGRAM TO OPEN THE ODU WINDOW TO VIEW THE ODU DETAILS ODU WINDOW FOR (1+1) CONFIGURATION ODU WINDOW FOR (1+0) CONFIGURATION CLICK THE ODU TAB TO OPEN THE ODU WINDOW TO VIEW THE ODU DETAILS PNMT

15 ODU DETAIL PNMT TX SIDE ALARMS AND STATUS /MONITORING ALARMS
IF INPUT – IF INPUT LEVEL IN THE ODU FALLS BELOW (APPROXIMATELY) -63 dB TX APC – ODU TX SIDE SYNTHESIZER IS UNLOCKED TX POWER – TRANSMIT POWER DECREASED BY 3 TO 5 dB STATUS AND MONITORING TX ATTENUATION – INDICATES THE ATTENUATION VALUE USED IN MTPC MODE TX POWER – INDICATES THE ODU TRANSMIT POWER AS DETECTOR VOLTAGE AND IN dBm (1+1) CONFIGURATION SELECTED/NOT SELECTED STATUS GREEN SELECTED WHITE NOT SELECTED RX SIDE ALARMS AND STATUS /MONITORING ALARMS RX LEVEL – ODU RECEIVE LEVEL FALLS BELOW SQUELCH LEVEL RX APC – ODU RX SIDE SYNTHESIZER IS UNLOCKED STATUS AND MONITORING RX LEVEL – INDICATES THE ODU RX LEVEL AS THE AGC VOLTAGE AND IN dBm COMMON ALARMS AND STATUS /MONITORING ALARMS ODU-IDU LINK – INDICATES THE STATUS OF THE COMMUNICATION BETWEEN IDU AND ODU STATUS AND MONITORING ODU TYPE – INDICATES THE TYPE OF ODU CONNECTED TO THE V4 PASOLINK STATUS COLORS GREEN NORMAL RED ALARM PNMT

16 IDU WINDOW CLICK THE IDU SYMBOL IN THE BLOCK DIAGRAM TO OPEN THE IDU WINDOW TO VIEW THE IDU DETAILS IDU WINDOW FOR (1+0) CONFIGURATION IDU WINDOW FOR (1+1) CONFIGURATION CLICK THE IDU TAB TO OPEN THE IDU WINDOW TO VIEW THE IDU DETAILS PNMT

17 IDU DETAIL PNMT TX SIDE IDU ALARMS
MOD – MODULATOR 850 MHz PLL OSCILLATOR UNLOCK ALARM TX DPU – LOSS OF TX SIDE CLOCK (1+1) CONFIGURATION ON LINE SELECTED/NOT SELECTED STATUS STATUS COLORS GREEN SELECTED GREEN NORMAL WHITE NOT SELECTED RED ALARM PINK MINOR ALARM RX SIDE IDU ALARMS DEM – RX CARRIER NOT SYNCHRONIZED OR LOST LOW BER – WHEN THE RECEIVE BER IS > 10-6 HIGH BER – WHEN THE RECEIVE BER IS >10-3 BER ALARM – ALARM TRIGGER POINT SELECTABLE (10-3,10-4,10-5 AND 10-6) FRAME ASYNC – LOSS OF RX FRAME SYNCHRONIZATION AT THE RX DPU RX CLK LOSS – LOSS OF RX SIDE CLOCK IDU COMMON ALARMS ODU-IDU LINK – STATUS OF THE ODU-IDU IF LINK CPU – STATUS OF THE IDU CPU WAY SIDE( OPTION) ALARMS INPUT – LOSS OF WS INPUT SIGNAL IN THE WS INTFC CARD BP OUTPUT – RX WS SIGNAL LOSS FROM DEMODULATOR (WS INTFC CARD) AIS SEND – STATUS AIS SENT OUT FORM THE WS INTFC CARD AIS RECEIVED – AIS DETECTED IN WS INPUT SIGNAL ALARM INHIBIT – WHEN WS SIGNAL IS NOT USED ALARM INHIBIT STATUS Normal LAN INTFC (OPTION) ALARMS Port 1 Port 2 LAN INTFC – LAN INTERFACE OPTION CARD IS NORMAL OR FAULTY Normal Normal LAN LINK – LAN PORT 1 & 2 LINK STATUS NORMAL OR ALARM Normal Normal LAN COLLISION – COLLISION STATUS OF THE LAN PORT 1 & 2 PNMT

18 IDU DETAIL PNMT CLICK THE CH BUTTON TO OPEN THE CHANNEL CONTROL WINDOW
LOOPBACK 1 CONTROL LOOPBACK 2 CONTROL CH ALARM INHIBIT CONTROL STATUS COLORS GREEN NORMAL RED ALARM YELLOW MAINTENANCE BP OUTPUT – RX 2MB SIGNAL LOSS DETECTED FROM DEMODULATOR NORMAL/ALARM/INHIBIT NORMAL/ALARM NORMAL/SEND NORMAL/RECEIVED ON/OFF 2MB CH STATUS AND ALARMS ON/OFF INPUT – LOSS OF 2MB INPUT SIGNAL ON/OFF BP OUTPUT – RX 2MB SIGNAL LOSS DETECTED FROM DEMODULATOR AIS SEND – AIS SENT OUT STATUS FORM THE 2MB INTFC CARD ALARM INHIBIT AIS RECEIVED – AIS DETECTED STATUS IN 2MB INPUT SIGNAL WS OFF LB-1– UNDER MAINTENANCE MODE NEAR END LOOPBACK STATUS LB-2 – UNDER MAINTENANCE MODE, TO FAR END LOOPBACK STATUS ALARM INHIBIT – ALARM INHIBIT STATUS OF NOT USED 2MB STREAMS WS CH STATUS AND ALARMS INPUT – LOSS OF 2MB WS INPUT SIGNAL BP OUTPUT – RX 2MB WS SIGNAL LOSS DETECTED FROM DEMODULATOR AIS SEND – AIS SENT OUT STATUS FORM THE WS INTFC CARD AIS RECEIVED – AIS DETECTED STATUS IN WS INPUT SIGNAL ALARM INHIBIT – ALARM INHIBIT STATUS OF NOT USED 2MB STREAMS PNMT

19 CHANNEL CONTROL INDICATE LOOPBACK ON, YELLOW BACKGROUND INDICATE MAINTENANCE MODE IN THE IDU WINDOW CLICK ON THE CH # TO BE CONTROLLED. SELECTED CHANNEL CONTROL WINDOW OPENS INDICATE CHANNEL ALARMS INHIBIT ON INDICATE CHANNEL ALARMS INHIBIT ON LB1 TAB PROVIDES NEAR END LOOPBACK. SELECT ON OR OFF AND CLICK ON EXECUTE TO ENABLE NEAR END LOOPBACK ON THE SELECTED CHANNEL. BEFORE ENABLING LOOPBACK SELECT MAINTENANCE MODE ON. OTHERWISE AN ERROR MESSAGE. IS DISPLAYED ALARM TAB PROVIDES INHIBIT OF ALARM ON THE SELECTED CHANNEL. USED TO INHIBIT ALARMS FROM THE UNUSED 2 MB CHANNELS. ON – INHIBIT ALARMS OFF - ENABLE ALARMS CLICK EXECUTE TO SELECT THE CHANGE LB2 TAB PROVIDES FAR END LOOPBACK. SELECT ON OR OFF AND CLICK ON EXECUTE TO ENABLE FAR END LOOPBACK ON THE SELECTED CHANNEL.. PNMT

20 CHANGE PASSWORD CLICK ON CHANGE PASSWORD IN THE SYSTEM DROPDOWN MENU TO OPEN THE CHANGE PASS WORD WINDOW. ENTER THE OLD PASSWORD ENTER THE NEW PASSWORD RE-ENTER THE NEW PASSWORD TO CONFIRM CLICK OK TO CHANGE THE PASSWORD. CLICK CANCEL TO EXIT WITHOUT CHANGING PASSWORD PNMT

21 ALARM BUZZER CLICK ON ALARM BUZZER ON THE SYSTEM DROP DOWN MENU TO OPEN THE ALARM BUZZER SETTING WINDOW. SELECT NO SOUND TO DISABLE THE BUZZER SELECT WAVE FILE TO ENABLE THE BUZZER. THE BUZZER SOUND CAN BE CHANGED BY SELECTING A DIFFERENT WAV FILE. USE BROWSE TO LOCATE THE PATH TO THE WAV FILE. CLICK HERE TO TEST THE BUZZER SOUND CLICK OK TO IMPLEMENT THE OPTION SELECTED OR CLICK CANCEL TO EXIT WITHOUT CHANGING THE SETTINGS. SELECT BEEP TO ENABLE THE BUZZER WITH BEEP FREQUENCIES INSTEAD OF WAVE FILE SOUND BEEP FREQUENCY CAN BE DEFINED BY CLICKING ON EDIT AND SELECTING THE FREQUENCIES AND DURATION FOR EACH FREQUENCY. CLICK THE ARROW KEY TO ADD TO THE LIST. SEVERAL FREQUENCIES CAN BE ADDED TO THE BEEP SIGNAL. SELECTED FREQUENCIES CAN BE DELETED BY SELECTING THE FREQUENCY FROM THE LIST AND CLICKING ON THE DELETE SYMBOL. PNMT

22 SEARCH / CONNECT TO NETWORK ELEMENT
CLICK CONNECT ON THE SYSTEM DROP DOWN MENU TO LIST THE LOCAL NEs THE PNMT IS CONNECTED TO. LIST MENU CLICK THE SEARCH FOR NETWORK ELEMENT TO SEARCH AND LIST THE OTHER NEs IN THE NETWORK TO VIEW A REMOTE NE FROM THE NETWORK ELEMENT LIST, SELECT AND HIGHLIGHT THE NE IN THE LIST. THEN CLICK THE CONNECT TO NETWORK ELEMENT FROM THE LIST DROP DOWN MENU. SELECT YES FROM THE DIALOG BOX. THE SELECTED NE AND ITS OPPOSITE NE WILL BE DISPLAYED IN THE LINK SUMMARY WINDOW. TOOL BAR ITEMS CONNECT TO NETWORK ELEMENT SEARCH FOR NETWORK ELEMENT PNMT

23 HELP FUNCTION PNMT HELP FUNCTION IS AVAILABLE AS PNMT MANUAL IN PDF FILE FORMAT. IF THE ACROBAT READER IS INSTALLED IN THE PNMT PC, CLICKING HELP AND SELECTING THE RELEVANT PNMT FILE WILL OPEN THE PDF FILE TO PROVIDE HELP FUNCTION TO THE USER. BUZZER STOP – ICON IS ACTIVE ONLY WHEN THE, THE ALARMED EQUIPMENT DISPLAY WINDOW IS SELECTED FROM THE TABs OR FROM THE BLOCK DIAGRAM SYMBOLS. DISPLAY THE PNMT SOFTWARE VERSION INFORMATION REFRESH – REFRESH METERING ITEMS CONNECT - OPEN THE NE LIST WINDOW OPEN THE LOGIN/LOGOUT WINDOW PNMT

24 EQUIPMENT CONFIGURATION WINDOW
INDICATES THE ODU FREQUENCY BAND INFORMATION AND TX/RX FREQUENCIES INDICATES THE TX POWER CONTROL MODE AND TX ATT SHOW THE TYPE AND NUMBER OF OPTIONAL INTERFACE CARDS MOUNTED SHOW THE CURRENT IDU CONFIGURATION SHOW THE LAN SIGNAL STATUS FOR PORT1 AND PORT2, WHEN MAIN LAN INTFC OPTION IS USED SHOW THE WS CHANNEL INFORMATION SHOW THE SERVICE CHANNEL INFORMATION SHOW IP ADDRESS AND NAME OF THE SELECTED NE PNMT

25 FREQUENCY AND POWER SETTING
ODU SECTION OF THE EQUIPMENT SETUP WINDOW FOR THE SELECTED PASOLINK HAS THREE CONTROLS, FREQUENCY PLAN , TX ATTENUATION AND TX POWER CONTROL SETTING. IN THE CASE OF (1+1) HOT STANDBY CONFIGURATION, FREQUENCY IS SET FOR BOTH ODUs. CLICK ON THE FREQUENCY PLAN BUTTON TO SELECT THE ODU TX AND RX FREQUENCIES. INFORMATION ABOUT THE ODU FREQUENCY BAND ARE DISPLAYED This information may include : TX frequency used is High band or Low band Frequency Sub band used A, B, C, or D. Default Channel and TX frequency set in the ODU. CH Separation shift frequency CLICK ON THE TX ATTENUATION BUTTON TO SET THE TX ATTENUATION FOR MTPC. REFER TO THE RADIO FREQUENCY ASSIGNMENT TABLES TO SELECT THE CHANNEL NUMBER CORRESPONDING TO THE REQUIRED TRANSMIT AND RECEIVE FREQUENCIES. SELECT THE CHANNEL NUMBER AND THE CORRESPONDING TX AND RX FREQUENCIES FOR THE SELECTED CHANNEL. ARE DISPLAYED CLICK THE EXECUTE BUTTON TO CHANGE THE FREQUENCIES. THIS OPERATION WILL INTERRUPT THE TRAFFIC CLICK THE CLOSE BUTTON TO EXIT THE FREQUENCY PLAN WINDOW. SELECT THE AMOUNT OF ATTENUATION REQUIRED AND CLICK THE EXECUTE BUTTON. THE TX ATTENUATION RANGE OF ODU IS 0 TO 30 dB CLICK CLOSE TO EXIT THE TX ATTENUATION SETTING WINDOW. PNMT

26 ATPC SETTING PNMT TX POWER CONTROL RX THRESHOLD LEVEL
SELECTS THE TX POWER CONTROL MODE ATPC OR MTPC. WHEN ATPC IS SELECTED, “ATPC RX THRESHOLD” , ”ATPC MAX POWER” AND “ATPC MIN POWER” BUTTONS ARE ACTIVE. WHEN TC CONTROL MODE IS ATPC, TX ATTENUATION SETTING VALUE IS IGNORED WHEN TX CONTROL MODE IS CHANGED FROM ATPC TO MTPC, THE TX ATTENUATION SETTING IS AUTOMATICALLY SET TO THE ATPC MAX POWER SETTING VALUE. RX THRESHOLD LEVEL WHEN THE MONITORED RX SIGNAL LEVEL FALLS BELOW THIS LEVEL, CONTROL SIGNAL SENT TO THE OPPOSITE STATION INITIATE THE ATPC FUNCTION. THIS IS EFFECTIVE ONLY WHEN THE OPPOSITE STATION IS SET TO ATPC MODE AUTOMATIC TX POWER MAX AND MIN RANGE CLICK THE APPROPRIATE BUTTON TO OPEN THE SELECTED SETTING WINDOW.. ATPC RANGE DEFINES THE MAXIMUM AND MINIMUM TRANSMISSION POWER DURING ATPC OPERATION. IN MTPC MODE THIS MENU ITEM DOES NOT APPEAR. AFTER SELECTING OR SETTING THE PARAMETER CLICK EXECUTE BUTTON TO IMPLEMENT THE SETTING. VALUE SET IS THE ATTENUATION IN dB FROM MAX ODU POWER. IF THE MAXIMUM OUTPUT POWER OF THE ODU IS +20 DBM, THEN FOR AN ATPC MAX PWR SETTING OF 0DB AND ATPC MIN PWR SETTING OF -10DB, THE ODU OUTPUT POWER DURING ATPC OPERATION CAN VARY BETWEEN +20 DBM AND +10 DBM IN ALL SETTING WINDOWS, CLICK CLOSE TO EXIT THE WINDOW PNMT

27 IDU SETTING PNMT BIT RATE SETTING
IDU SECTION OF THE EQUIPMENT SETUP WINDOW FOR THE SELECTED PASOLINK HAS CONTROL SETTINGS FOR THE MAIN SIGNAL. CLICK BIT RATE BUTTON TO OPEN THE BIT RATE SETTING WINDOW. THIS FUNCTION APPLIES TO THE VARIABLE BIT RATE IDUs. SELECT THE BIT RATE AND CLICK THE EXECUTE BUTTON TO CHANGE THE BIT RATE SETTING.. REDUNDANCY CLICK REDUNDANCY BUTTON TO OPEN THE REDUNDANCY CONFIGURATION SETTING WINDOW. SELECT THE REQUIRED CONFIGURATION. CLICK ON THE EXECUTE BUTTON TO SET THE REDUNDANCY CONFIGURATION. BER THRESHOLD SETTING CLICK BER THRESHOLD BUTTON TO OPEN THE BER THRESHOLD SETTING WINDOW. SELECT THE DESIRED VALUE FOR THE BER THRESHOLD. CLICK ON THE EXECUTE BUTTON TO SET THE BER THRESHOLD VALUE. FRAME ID CLICK FRAME ID BUTTON TO OPEN THE FRAME ID SETTING WINDOW. SELECT THE FRAME ID AND CLICK ON THE EXECUTE BUTTON TO SET IT. AT THIS BER THRESHOLD VALUE AIS SIGNAL IS INSERTED TO THE 2MB STREAMS MAKE SURE THAT BOTH NEs IN THE HOP HAVE THE SAME FRAME ID VALUE. PNMT

28 AIS SEND / RCVD SETTING PNMT
IN THE PASOLINK SYSTEM WHEN AIS IS DETECTED FROM THE INPUT 2MB STREAM AIS RCVD CONDITION IS DECLARED. THIS CONDITION CAN BE DEFINED AS AN ALARM CONDITION OR STATUS CHANGE EVENT. SIMILARLY AIS IS SENT TO THE 2MB STREAM IN THE RECEIVE DIRECTION UNDER CERTAIN CONDITIONS. AIS SEND CAN ALSO BE DEFINED AS AN ALARM CONDITION OR STATUS CHANGE EVENT. CLICK AIS RCVD BUTTON TO OPEN THE AIS RCVD SETTING WINDOW. CLICK AIS SEND BUTTON TO OPEN THE AIS SEND SETTING WINDOW. SELECT AIS SEND CONDITION AS AN ALARM CONDITION OR STATUS CONDITION. SELECT AIS RECEIVED CONDITION AS AN ALARM CONDITION OR STATUS CONDITION. CLICK EXECUTE TO CARRY OUT THE SETTING. CLICK EXECUTE TO CARRY OUT THE SETTING. CLICK CLOSE TO EXIT CLICK CLOSE TO EXIT PNMT

29 SERVICE CHANNEL SETTING
OPTION PANEL STATUS SHOWS THE OPTION CARDS MOUNTED IN THE IDU. OVERHEAD SERVICE CHANNELS SC1 EOW Analog SC2 DSC3 ASC INTFC or DSC INTFC Option SC3 DSC4 Digital SC4 DSC1 9.6Kbps RS 232C or 64Kbps with G703/V11 card SC5 DSC2 9.6Kbps RS232C / RS422 / RS485 SC6 NMS SERVICE CHANNELS USED IN THE PASOLINK IS SHOWN ON THE TABLE. SC2 AND 3 NEEDS OPTIONAL ANALOG OR DIGITAL SERVICE CHANNEL INTERFACE CARD. SC4 AS A DEFAULT USE A 9.6K RS232 INTERFACE. IF THE OPTIONAL 64K INTERFACE CARDS ARE MOUNTED. THEN THE SC4 BUTTON IS ACTIVE TO SELECT EITHER 9.6 OR 64K. INTERFACE WHEN OPTIONAL 64K INTERFACE IS MOUNTED THIS BUTTON IS ACTIVE.. CLICK ON SC4 BUTTON TO OPEN THE SC4 SETTING WINDOW. CLICK ON SC5 BUTTON TO OPEN THE SC5 SETTING WINDOW. 64K V.11 64K G703 9.6K RS-232 SC4 SELECT THE REQUIRED OPTION AND CLICK EXECUTE. CLICK CLOSE TO EXIT THE WINDOW PNMT

30 PMC CARD SETTING THE NAME ENTERED TO IDENTIFY THE NETWORK ELEMENT CAN BE CHANGED FORM THIS WINDOW. A MAXIMUM OF 32 CHARACTERS CAN BE USED. FROM THE EQUIPMENT SETUP WINDOW CLICK THE NE NAME BUTTON TO OPEN THE NE NAME SETTING WINDOW. ENTER THE NAME AND CLICK EXECUTE TO SHOW THE NAME IN THE EQUIPMENT SETUP WINDOW. CLICK THE NOTE BUTTON TO OPEN THE NOTE WINDOW. A NOTE DESCRIBING THE NETWORK ELEMENT CAN BE ENTERED FROM THIS WINDOW. UP TO 80 CHARACTERS CAN BE USED IN THIS FIELD ENTER THE NOTE AND CLICK EXECUTE TO SHOW THE NOTE IN THE EQUIPMENT SETUP WINDOW. PNMT

31 MAINTENANCE CLICK MAINTENANCE, ON THE, CONFIGURATION DROP DOWN MENU TO OPEN THE MAINTENANCE WINDOW TO CARRY OUT ANY MAINTENANCE CONTROL ,SET THE SELECTED NE TO MAINTENANCE MODE. CLICK THE MAINT BUTTON ON THE MAINTENANCE WINDOW TO OPEN MAINTENANCE MODE SELECTION WINDOW. SELECT MAINT MODE ON OR OFF AND CLICK EXECUTE TO IMPLEMENT THE MODE SELECTION THIS CONTROL TRANSMIT AN UN- MODULATED CARRIER FOR MEASUREMENT PURPOSE. CLICK THE CW BUTTON ON THE MAINTENANCE WINDOW TO OPEN THE CW CONTROL WINDOW. CLICK ON/OFF AND EXECUTE TO IMPLEMENT THE CONTROL. THIS CONTROL INHIBIT INSERTION OF AIS DURING BER ALARM CONDITION FOR MEASUREMENT PURPOSE. CLICK THE BER AIS BUTTON ON THE MAINTENANCE WINDOW TO OPEN THE BER AIS CONTROL WINDOW. CLICK ON/OFF AND EXECUTE TO IMPLEMENT THE CONTROL. THIS CONTROL MUTE THE OUTPUT POWER OF THE SELECTED PASOLINK CHANNEL . CLICK THE TX MUTE BUTTON ON THE MAINTENANCE WINDOW TO OPEN THE TX MUTE CONTROL WINDOW. CLICK ON/OFF AND EXECUTE TO IMPLEMENT THE CONTROL. THESE CONTROL ARE AVAILABLE FOR (1+1) CONFIGURATION. PROVIDES MANUAL SWITCH OVER OF PASOLINK CHANNEL FOR NORMAL OPERATION SELECT AUTO FOR AUTO REDUNDANCY SWITCHING.. TO CLOSE ANY MAINTENANCE CONTROL WINDOW CLICK CLOSE BUTTON. TO NORMALIZE MAINTENANCE MODE NORMALIZE MAINTENANCE CONTROLS FIRST. PNMT

32 AUX I/O WINDOW - MONITORING
AUXILIARY INPUT / OUTPUT FACILITY CAN BE USED TO MONITOR SIX EXTERNAL MONITOR ITEMS AND FOUR EXTERNAL CONTROL ITEMS USING THE PASOLINK MANAGEMENT SYSTEM. MONITORING ITEMS ARE CONNECTED THROUGH OPTICAL COUPLERS AND CONTROLS VIA RELAYS. THESE ITEMS ARE ALSO KNOWN AS HOUSEKEEPING ALARMS AND CONTROLS. CLICK THE AUX SYMBOL IN THE BLOCK DIAGRAM OR AUX I/O TAB TO VIEW THE AUX ALARM/STATUS/CONTROL DISPLAY CONFIGURE CONTROL RELAY OUTPUTS CLICK THE OUTPUT 1-4 BUTTONS TO CONFIGURE THE EXTERNAL CONTROLS ENTER THE NAME TO APPEAR FOR SELECTED CONTROL ITEM ( UP TO 32 CHARACTERS) ENTER THE LABEL FOR EACH CONDITION EVENT ON AND EVENT OFF CLICK EXECUTE TO CARRY OUT THE CHANGE ENTER THE SELECTED EXTERNAL ALARM NAME, (UP TO 32 CHARACTERS) CONFIGURE ALARM INPUTS CLICK THE INPUT 1-6 BUTTONS TO CONFIGURE THE EXTERNAL ALARM SELECT THE CONDITION FOR ALARM, EVENT ON OR EVENT OFF EXTERNAL MONITORING ITEMS CAN BE DEFINED AS ALARMS OR AS STATUS CHANGE. ENTER THE LABEL FOR ALARM/ STATUS EVENT ON AND EVENT OFF. CLICK EXECUTE TO CARRY OUT THE CHANGE CLICK THE CLOSE BUTTON TO CLOSE THE WINDOW PNMT

33 PMC & VERSION WINDOWS PNMT
CLICK THE PMC SYMBOL ON THE BLOCK DIAGRAM OR THE PMC TAB TO DISPLAY THE PMC WINDOW FOR THE SELECTED NE. CLICK THE VERSION TAB TO DISPLAY THE VERSION INFORMATION WINDOW FOR THE SELECTED NE. VERSION WINDOW DISPLAY THE DATE OF MANUFACTURE , SOFTWARE VERSIONS, SERIAL NUMBER, CODE NUMBER ETC.. OF THE PASOLINK EQUIPMENT IN THE SELECTED NETWORK ELEMENT. CONFIGURATION AND SETTING OF THE PASOLINK MANAGEMENT CARD IS PROVIDED IN THIS WINDOW. PNMT

34 DATE TIME SETTING DATE AND TIME STORED IN THE SELECTED NETWORK ELEMENT’S PM CARD CAN BE DISPLAYED AND ADJUSTED FORM THIS CONTROL ITEM [PMC WINDOW] TO DISPLAY THE CURRENT DATE/TIME STORED IN THE PM CARD, SELECT GET DATE/TIME AND CLICK EXECUTE. CLICK DATE/TIME BUTTON IN THE PMC WINDOW TO OPEN THE DATE/TIME SETTING CONTROL WINDOW THE CURRENT DATE/TIME STORED IN THE PM CARD, IS DISPLAYED. TO CHANGE THE PM CARD DATE TIME SETTING, SELECT SET DATE/TIME. TO CHANGE THE PM CARD DATE TIME SETTING, SELECT SET DATE/TIME. CHANGE THE DATE /TIME SETTING AS REQUIRED, CLICK THE EXECUTE BUTTON. TO DISPLAY AND SET THE DATE/TIME SET IN THE PNMT PC TO THE PM CARD, SELECT DISPLAY PC TIME BOX AND CLICK THE EXECUTE BUTTON. PNMT

35 DOWN LOAD CONFIGURATION FILES
THIS FUNCTION IS USED TO DOWN LOAD CONFIGURATION FILES CREATED BY THE NETWORK CONFIG TOOL TO THE PM CARD IN THE SELECTED NETWORK ELEMENT. THERE ARE TWO FILES CREATED FOR EACH NE, SYSTEM.CFG CONTAINS THE IP ADDRESS OF THE PM CARD AS WELL AS THE IP ADDRESS OF THE OPPOSITE STATION. THE NETWORK.CFG FILE CONTAINS THE INFORMATION ABOUT THE PASOLINK NETWORK WHERE THE PM CARD IS LOCATED. CLICK THE CONFIGURATION FILE BUTTON UNDER THE DOWNLOAD (PC>>PMC) IN THE PMC WINDOW, TO OPEN THE DOWNLOAD CONFIGURATION FILE WINDOW. DOWN LOAD SELECT EACH CONFIG FILE ONE BY ONE FROM THE TYPE WINDOW [PMC WINDOW] BROWSE AND SELECT THE PATH/LOCATION TO THE FILE SELECTED IN THE TYPE WINDOW. CLICK EXECUTE BUTTON TO DOWN LOAD THE SELECTED CONFIG FILE.. REPEAT THE DOWNLOAD PROCEDURE FOR THE OTHER CONFIG FILE.. UPDATE A MESSAGE WINDOW INDICATE THE STATUS OF THE DOWNLOAD OPERATION AND IT WILL CLOSE AUTOMATICALLY ONCE THE OPERATION IS OVER AFTER THE SUCCESSFUL DOWN LOAD OF THE CONFIGURATION FILES. CLICK UPDATE BUTTON. UPDATE CONFIGURATION FILE WINDOW OPENS. System Config WARNING SELECT THE APPROPRIATE BOX FOR THE TYPE OF CONFIGURATION FILE(S) THAT WILL BE UPDATED. Network Config MAKE SURE THAT THE CORRECT CONFIGURATION FILE IS DOWN LOADED TO THE PM CARD IN THE CORRECT NE. INCORRECT CONFIGURATION FILE WILL LEAD TO PM CARD OR NETWORK FAILURE ME Config PPP Config CLICK OK BUTTON TO START THE UPDATE OPERATION.. MAKE SURE THAT YOU HAVE SUCCESSFULLY DOWN LOADED THE CONFIGURATION FILE BEFORE DOING UPDATE. OTHERWISE THE PM CARD WILL SWITCH TO AN EMPTY ROM THAT MAY CAUSE PM CARD FAILURE. With ROM (PMC Program ) Switching WHEN UPDATING SYSTEM.CFG FILE , PMC TO PMC COMMUNICATION WILL BE LOST WHEN PM CARD INITIALIZES TO THE NEW SYSTEM CONFIGURATION. DURING THIS TIME PNMT CONNECTION TO THE PASOLINK WILL BE LOST BUT WILL AUTOMATICALLY BE RECONNECTED AFTER THE PMC RESETS Execute CLICK CLOSE BUTTON WHEN DONE PNMT

36 DOWN LOAD PROGRAM FILE PNMT
THIS FUNCTION IS USED TO UPDATE THE APPLICATION PROGRAM ON THE PM CARD. THIS OPERATION AFFECTS THE ONLY THE PMC TO PMC COMMUNICATION. AND WILL NOT DISRUPT THE RADIO LINK. CLICK ON THE PROGRAM FILE BUTTON UNDER THE DOWNLOAD (PC>>PMC) IN THE PMC WINDOW. [PMC WINDOW] ENTER THE PATH TO THE PROGRAM FILE TO BE DOWNLOADED OR CLICK BROWSE TO LOCATE THE PROGRAM FILE. A:\pm.pof PM CARD CAN BE RESET USING THIS FUNCTION CLICK THE PMC RESET BUTTON ON THE PMC WINDOW. CLICK THE EXECUTE BUTTON TO START DOWNLOAD OPERATION A MESSAGE WINDOW APPEARS TO SHOW THE STATUS OF THE DOWNLOAD OPERATION, AND WILL CLOSE AUTOMATICALLY ONCE THE DOWNLOAD IS COMPLETED. CLICK ON THE PMC RESET BUTTON TO SWITCH TO THE NEW PROGRAM FILE WARNING MAKE SURE THAT THE CORRECT PROGRAM FILE IS DOWNLOADED TO THE PM CARD. INCORRECT PROGRAM FILE WILL LEAD TO PM CARD FAILURE. SELECT WITH ROM (PMC PROGRAM) SWITCHING OPTION IF YOU WANT TO SWITCH TO A NEWLY DOWNLOADED PMC PROGRAM FILE RESETTING THE PMC WILL NOT AFFECT THE TRAFFIC. THE CONNECTION TO THE SELECTED PASOLINK WILL BE LOST FOR FEW MINUTES AND WILL BE RECONNECTED AUTOMATICALLY. CLICK EXECUTE BUTTON TO RESET THE PM CARD. PNMT

37 UPLOAD CONFIGURATION FILE
THIS FUNCTION IS USED TO UPLOAD THE CONFIGURATION FILES FROM THE PM CARD OF THE SELECTED NE TO THE PNMT PC. [PMC WINDOW] CLICK THE CONFIGURATION FILE UNDER THE UPLOAD (PM>>PC) TO OPEN THE UPLOAD CONFIGURATION FILE WINDOW. SELECT THE TYPE OF CONFIG FILE TO BE UPLOADED FROM THE TYPE WINDOW., SYSTEM CONFIG OR NETWORK CONFIG. ENTER THE LOCATION THE FILE TO BE UPLOADED AND THE FILE NAME IN THE FILE WINDOW. USE BROWSE TO LOCATE THE DIRECTORY IF NECESSARY. CLICK EXECUTE BUTTON TO START THE UPLOAD OPERATION. A MESSAGE WINDOW APPEARS TO SHOW THE STATUS OF THE UPLOAD OPERATION, AND WILL CLOSE AUTOMATICALLY ONCE THE OPERATION IS COMPLETED.. AFTER THE UP LOAD IS FINISHED CLICK THE CLOSE BUTTON TO CLOSE THE WINDOW. PNMT

38 EVENT LOG PNMT NE SPECIFIC MENU BAR
A MESSAGE WINDOW SHOWS THE PROGRESS OF THE UPLOAD CLICK ON THE EVEN LOG IN THE NE SPECIFIC MENU BAR TO UPLOAD THE EVEN LOG ITEMS FROM THE SELECTED NE. EVENT LOG VIEW WINDOW SHOWS ALARM EVENTS, COMMAND EVENTS AND STATUS CHANGES. DIFFERENT COLORS SHOWS THE TYPE OF EVENT. EVENT LOG IS PRESENTED IN A TABLE FORM SHOWING THE DATE OF THE EVENT , THE ITEM THAT TRIGGERED THE EVENT AND THE STATUS CHANGE. CLICK FILE-UPLOAD TO REFRESH THE EVENT LOG DISPLAY CLICK FILE-SAVE AS TO SAVE THE EVENT LOG TO CLICK FILE-PRINT TO PRINT THE EVENT LOG INFORMATION PNMT

39 LINK PERFORMANCE MONITOR
NE SPECIFIC MENU BAR THE FOLLOWING PERFORMANCE ITEMS CAN BE MONITORED ACCORDING TO THE G.826 RECOMMENDATIONS. CLICK ON THE LINK PERFORMANCE MONITOR IN THE NE SPECIFIC MENU BAR OF THE LINK SUMMARY WINDOW OF THE PASOLINK TO BE MONITORED. ES ERROR SECONDS SES SEVERELY ERROR SECONDS UAS UNAVAILABLE SECONDS BBE BACKGROUND BLOCK ERRORS CURRENT BER VALUE IS SHOWN IN THIS FIELD THE RED COLOR IN THE PERFORMANCE MONITOR WINDOW INDICATES THE OCCURRENCE OF PERFORMANCE ITEMS EXCEEDING THE THRESHOLD VALUE. THE THRESHOLD VALUES CAN BE SET IN THRESHOLD WINDOW. ALL DATA CAN BE RESET BY USING ALL DATA RESET BUTTON. ( MAKE SURE THAT THE CURRENT DATA HAS BEEN SAVED AS THIS OPERATION WILL DELETE ALL THE PERFORMANCE DATA IN THE CURRENT WEEK.) THRESHOLD VALUE SETTING CLICK THE THRESHOLD(%) BUTTON TO OPEN THE THRESHOLD SETTING WINDOW. SELECT THE PERFORMANCE ITEM THAT IS TO BE CONFIGURED ON THE TABLE SHOWN. SET THE VALUE WHEN THE ALARM OCCUR AND WHEN THE ALARM RECOVER IN THE APPROPRIATE FIELD. AFTER SETTING ALL THE THRESHOLD VALUES CLICK EXECUTE TO ACTIVATE THE NEW SETTING. CLOCK CLOSE TO CLOSE THE THRESHOLD SETTING WINDOW.. PNMT

40 LINK PERFORMANCE MONITOR
THIS WINDOW CONTAINS THE LINK PERFORMANCE DATA OF THE LAST .8 DAYS. CLICK ON THE DETAIL BUTTON IN THE LINK PERFORMANCE MONITOR WINDOW TO DISPLAY THE WEEKLY DETAIL WINDOW. CLICK ON A DATE BUTTON TO DISPLAY THE DAILY DATA WINDOW FOR THE SELECTED DATE THE DATE BUTTONS ON THE RIGHT HAND SIDE OF THE TABLE ARE SELECTABLE. AND CAN OPEN THE SUMMARY DATA FOR THAT SPECIFIC DATE.. THE LINK PERFORMANCE MONITOR DAILY DATA WINDOW DISPLAY THE DETAILED 15MIN PERFORMANCE DATA CLICK FILE – SAVE AS TO SAVE THE DATA IN TEXT FORMAT CLICK FILE - UPLOAD TO REFRESH THE DATA PNMT

41 NEC International Training, Ltd. Yokohama Training Center
PASOLINK V4 SOFTWARE NEC International Training, Ltd. Yokohama Training Center PNMT