1

2

3 Code Jeopardy Lori Greene, AHC/CDC, CCPR, FDAI Steve Monroe, AHC, CDT, FDAI Lindsey Weiss Ingersoll Rand Security Technologies

4 www.iHATEhardware.com or www.iDIGhardware.com

5 Let Me Let Me Hot Wired! In! Out! Stuff! $400 $400 $400 $400 $600 $600
$800 $800 $800 $800 This slide plays the Jeopardy music. When you’re sick of the music, advance to the next slide which is the game board. $1000 $1000 $1000 $1000

6 Let Me Let Me Hot Wired! In! Out! Stuff! $400 $400 $400 $400 $400 $400
$600 $600 $600 $600 $600 $600 $600 $600 $800 $800 $800 $800 $800 $800 $800 $800 Prior to beginning the game, I have the teams choose team names and write them on a tent card. I pick the name I like best to go first. That team chooses a category and a dollar amount (they don’t have to go in any particular order). The categories are: Let Me In = Accessibility Let Me Out = Egress Hot Stuff = Fire Doors Wired = Electrified Hardware Don’t click on Alex Trebeck until you’re ready for Final Jeopardy. Clicking twice on a dollar value will take you to the applicable question. Then advance through the slides until you reach a black slide (don’t advance past the black slide). Click anywhere on the black slide to return to the board. You can change the questions and answers, and you can add more slides, as long as you add them before the black slide. The team that rings in first gets to answer the question. If they answer correctly, the dollar value is added to their score. If they answer incorrectly, the dollar value is subtracted from their score and the teams can ring in again. I let two teams try and if they’re still incorrect I just tell them the answer. It’s hard to play this game with only one instructor. I bring another SSC person with me to be the spotter (see who rings in first) and the scorekeeper. I hand out a bell or horn to each team, and I’ve also used flags when I’ve had large teams in a big room. When all of the questions have been asked/answered, click on Alex Trebeck to go to Final Jeopardy. Teams have to write down their wager before they see the question. They can wager up to their current point value. If any teams are in the red (always), I add enough points to each team to get the negatives into the positive. I collect the wagers and then read the question. I like to make it an open book question and let them use the code booklet. That gets them to open it up and check it out a bit. I collect the answers to Final Jeopardy. If a team gets it wrong, their wager is subtracted from their score. If they get it right, the wager is added to their score. I give out $10 Dunkin’ Donuts gift cards to the winners and $5 DD gift cards to the losers. $1000 $1000 $1000 $1000 $1000 $1000 $1000 $1000

7 What is the maximum height for a threshold on an accessible door?
$400

8 What is the maximum height for a threshold on an accessible door?
Ramp $400

9

10 According to ADA and ICC/ANSI A117
According to ADA and ICC/ANSI A is a lever handle required to return back toward the door? A) Yes B) No C) Only if the door is fire rated. $600

11 According to ADA and ICC/ANSI A117
According to ADA and ICC/ANSI A is a lever handle required to return back toward the door? A) Yes B) No, it is not required by either of these publications. C) Only if the door is fire rated. $600

12

13 What is the minimum clearance required for accessible door pulls?
D) No specific requirement. $800

14 What is the minimum clearance required for accessible door pulls?
D) No specific requirement. $800

15 Pulls GOOD ??? Projection of pull is not specified.
Pull must be open so hand can slide through. GOOD ???

16

17 What is the minimum clear width of an accessible door?
A) 36”, measured between jambs B) 36”, measured between the face of the door at 90 degrees and the stop on the strike jamb C) 32”, measured between jambs D) 32”, measured between the face of the door at 90 degrees and the stop on the strike jamb $1000

18 What is the minimum clear width of an accessible door?
A) 36”, measured between jambs B) 36”, measured between the face of the door at 90 degrees and the stop on the strike jamb C) 32”, measured between jambs D) 32”, measured between the face of the door at 90 degrees and the stop on the strike jamb $1000

19

20

21

22 According to the IBC - where is it acceptable to install a deadbolt in a means of egress?
A) On the back door of a restaurant that is equipped with a lockset. B) On a door with panic hardware. C) On an individual public bathroom or fitting room that has a privacy set. D) On a guest room at the No-Tell Motel. E) Deadbolts are never allowed in a means of egress. $400

23 According to the IBC - where is it acceptable to install a deadbolt in a means of egress?
A) On the back door of a restaurant that is equipped with a lockset. B) On a door with panic hardware. C) On an individual public bathroom or fitting room that has a privacy set. D) On a guest room at the No-Tell Motel. E) Deadbolts are never allowed in a means of egress. $400

24 Egress doors must open with one motion and no prior knowledge or special tools (keys).

25 IBC “Exception 4: Doors from individual dwelling or sleeping units of Group R occupancies having an occupant load of 10 or less are permitted to be equipped with a night latch, dead bolt or security chain, provided such devices are openable from the inside without the use of a key or tool.”

26

27

28

29

30 Are panic devices required on electric rooms?
A) Yes, all electric rooms. B) No, as long as it is not a high hazard occupancy. C) Yes, if required by NFPA 80. D) Yes, if required by NFPA 70. $600

31 Are panic devices required on electric rooms?
A) Yes, all electric rooms. B) No, as long as it is not a high hazard occupancy. C) Yes, if required by NFPA 80. D) Yes, if required by NFPA 70. $600

32 National Electric Code
>600 volts >1200 amps transformer vaults “...door(s) shall open in the direction of egress and be equipped with panic bars, pressure plates, or other devices that are normally latched but open under simple pressure.”

33

34 According to the 2003 IBC - where is panic hardware required?
$800

35 According to the 2003 IBC - where is panic hardware required?
A) Any door serving more than 100 people. B) Any door serving more than 50 people. C) Doors serving certain occupancy types with more than 100 people. D) Doors serving certain occupancy types with more than 50 people. $800

36 According to the 2003 IBC - where is panic hardware required?
A) Any door serving more than 100 people. B) Any door serving more than 50 people. C) Doors serving certain occupancy types with more than 100 people. IBC 2006/2009 changes this to 50 people. D) Doors serving certain occupancy types with more than 50 people.

37 Bonus Question! Which occupancy types require panics when occupied by more than 100 people? Assembly Educational Day Care (NFPA 101)

38 Exit Devices Where panic hardware is required, actuating portion of device (touch-pad or cross-bar) must be at least half the width of the door.

39

40

41

42 Exit Devices No additional locking device (padlock, hasp, chain, deadbolt, etc.) shall be installed on a door which requires panic hardware.

43

44

45

46 According to the 2003 IBC - where are manual flush bolts allowed?
Entrance doors to retail establishments. Storage or equipment rooms. Doors that are left unlocked during the day. All of the above. $1000

47 According to the 2003 IBC - where are manual flush bolts allowed?
Entrance doors to retail establishments. Storage or equipment rooms. Doors that are left unlocked during the day. All of the above. $1000

48 The 2009 IBC contains new requirements related to flush bolts.
Doors not required for egress in dwelling units, and storage/equipment rooms. B, F, or S occupancy where doors serve an occupant load of <50 B, F, or S occupancy with sprinklers where inactive leaf is not needed for egress width I-2 patient rooms – self-latching bolts No dummy lever, push rail, etc. on inactive leaf for the 3

49

50 Where are door closers required?
A) Fire doors. B) Doors in smoke barriers. C) Storage rooms > 100 square feet. D) All of the above. $400

51 Where are door closers required?
A) Fire doors. B) Doors in smoke barriers. C) Storage rooms > 100 square feet. D) All of the above. Table $400

52 Bonus Question! Name a door that is fire-rated, but is not required to be self-closing or automatic-closing. Communicating door between hotel rooms.

53

54 What field modifications can be performed on a fire rated opening?
A) Any preparations as long as they are done by a certified installer. B) Prep for electric strike. C) Prep for mortise lock body. D) Prep for fire exit hardware with lever trim. E) Add a 10” x 10” glass lite. F) None of the above. $600

55 What field modifications can be performed on a fire rated opening?
A) Any preparations as long as they are done by a certified installer. B) Prep for electric strike. C) Prep for mortise lock body. D) Prep for fire exit hardware with lever trim. E) Add a 10” x 10” glass lite. F) None of the above. $600

56

57 Is there a product available that allows a fire door to be push/pull function?
A) No, fire doors have to latch. B) Yes, a fail-secure electric strike. C) Yes, fire exit hardware with electrified lever trim. D) Yes, fire exit hardware with electric latch retraction. $800

58 Is there a product available that allows a fire door to be push/pull function?
A) No, fire doors have to latch. B) Yes, a fail-secure electric strike. C) Yes, fire exit hardware with electrified lever trim. D) Yes, fire exit hardware with electric latch retraction. $800

59

60 What are the maximum clearances allowed for fire-rated wood doors?
$1000

61 What are the maximum clearances allowed for fire-rated wood doors?
$1000

62 What are the maximum clearances allowed for fire-rated wood doors?
A) 1/16” at the perimeter and meeting stiles, ¾” at the bottom. B) 1/8” at the perimeter and meeting stiles, ¾” at the bottom. C) 3/16” at the perimeter and meeting stiles, ¾” at the bottom. D) ¼” at the perimeter and meeting stiles, ¾” at the bottom. $1000

63 What are the maximum clearances allowed for fire-rated wood doors?
A) 1/16” at the perimeter and meeting stiles, ¾” at the bottom. B) 1/8” at the perimeter and meeting stiles, ¾” at the bottom. C) 3/16” at the perimeter and meeting stiles, ¾” at the bottom. D) ¼” at the perimeter and meeting stiles, ¾” at the bottom. $1000

64

65 According to ICC/ANSI A117
According to ICC/ANSI A which exterior doors require automatic operators? A) One exterior door of each public building must have an automatic operator. B) If the building has an occupant load of > 100, one exterior door must have an automatic operator. C) Automatic operators are not required by this publication. $400

66 According to ICC/ANSI A117
According to ICC/ANSI A which exterior doors require automatic operators? A) One exterior door of each public building must have an automatic operator. B) If the building has an occupant load of > 100, one exterior door must have an automatic operator. C) Automatic operators are not required by this publication. $400

67 Opening Force Exterior Hinged Doors – ???
(Of the New England states, only Massachusetts currently includes the 15-pound limit) Interior Hinged Doors - 5 pounds Sliding or Folding Doors - 5 pounds Fire doors shall have the minimum opening force allowable by the appropriate administrative authority (size 3 closer recommended). $400

68

69 If a high school is having trouble with books “disappearing” out of the library’s emergency exit which code-compliant product would help? A) An electric latch retraction panic device. B) A panic device with electrified lever trim. C) A delayed egress lock. D) An alarmed exit device. $600

70 If a high school is having trouble with books “disappearing” out of the library’s emergency exit which code-compliant product would help? A) An electric latch retraction panic device. B) A panic device with electrified lever trim. C) A delayed egress lock. D) An alarmed exit device. $600

71 Per the IBC, delayed egress devices are not allowed on Assembly, Educational, or High Hazard occupancies.

72 Delayed Egress Locks Not allowed on Assembly, Educational, or High Hazard occupancies. Must release upon fire alarm Must release upon loss of power Must be capable of being unlocked by a signal from an emergency control station

73 Delayed Egress Locks Must release within 15 seconds after force is applied for 1 second Manual rearm Audible local alarm Signage Occupant must not encounter more than 1 delay before entering an exit

74

75 According to the 2003 IBC - doors with electromagnetic locks require which of the following?
$800

76

77

78 According to the 2003 IBC - doors with electromagnetic locks require which of the following?
A) Motion Sensor B) Emergency Push Button C) Unlock on Fire Alarm/Sprinkler D) Unlock on Power Failure E) All of the above $800

79 According to the 2003 IBC, doors with electromagnetic locks require which of the following?
A) Motion Sensor B) Emergency Push Button C) Unlock on Fire Alarm/Sprinkler D) Unlock on Power Failure E) All of the above $800

80 Access-Controlled Egress Doors
Allowed in occupancies: Assembly, Business, Educational, Mercantile, R-1 (hotels), R-2 (multiple-family dwellings, dormitories) Lock must be released by all of the following: Sensor on egress side (or switched panic device?) Push button on egress side, unlocks door for 30 seconds Fire alarm or sprinkler system Loss of power

81

82

83 The stair doors in a high rise building must be equipped with what type of lock?
A) Fail safe electric lock B) Fail secure electric lock C) Fail safe electric strike D) Classroom function lockset E) Panic device with lockable lever handle $1000

84 The stair doors in a high rise building must be equipped with what type of lock?
A) Fail safe electric lock B) Fail secure electric lock C) Fail safe electric strike D) Classroom function lockset E) Panic device with lockable lever handle $1000

85 Stairwell Re-Entry Stairwell doors are often locked to prevent entry to restricted floors. During a fire, occupants must be able to move from the stairwell onto floors through doors that are normally locked.

86 Stairwell Re-Entry BOCA National Building Code
passage sets, or all doors unlock upon fire alarm ICC International Building Code stairs serving 4 stories or less are exempt ICC International Building Code – 2006, 2009 stairs serving 4 stories or less – doors must have the ability to be unlocked from the fire command center NFPA 101 / NFPA 5000 passage sets, or all doors unlock upon fire alarm, or “Selected Re-Entry”

87

88 Final Jeopardy! How much will you wager?

89 According to the 2003 IBC, what test standard must be used for fire doors?

90 According to the 2003 IBC, what test standard must be used for fire doors?
Positive pressure test – UL10C or NFPA 252 with the neutral pressure plane at 40” above the sill after 5 minutes.