2 Computer System Architecture
A major disparity exists between CPU speed and memory speed. CPU technology is advancing faster than memory technology. The CPU can process data faster than it can be fetched from compatibly priced main memory units. Main memory is the bottleneck in terms of system speed and cost. Systems need to include very fast and expensive cache memory.

3 Memory Hierarchy Small amount of very fast, expensive, volatile cache memory. volatile: contents disappear when the power goes off Gigabytes of medium-speed, medium-price, volatile main memory. RAM: random access memory Gigabytes or terabytes of slow, cheap, non-volatile disk storage.

4 Memory/Storage Speed Comparisons
Suppose your computer ran at human speeds. 1 CPU cycle: 1 second Then the time to retrieve one byte from: SRAM 5 seconds DRAM 2 minutes Flash 1 day Hard drive 2 months Tape 1,000 years

5 B-Trees A B-tree is a tree data structure suitable for disk drives.
It may take up to 11 ms to access data on disk. Today’s modern CPUs can execute billions of instructions per second. Therefore, it’s worth spending a few CPU cycles to reduce the number of disk accesses. B-trees are often used to implement databases.

6 B-Trees A B-tree is an m-ary tree. Mark Allen Weiss
Data Structures and Algorithms in Java (c) 2006 Pearson Education, Inc. All rights reserved

7 B-Trees A B-tree of order 5 for a disk drive: Mark Allen Weiss
Data Structures and Algorithms in Java (c) 2006 Pearson Education, Inc. All rights reserved

8 B-Tree Insertion Mark Allen Weiss
Data Structures and Algorithms in Java (c) 2006 Pearson Education, Inc. All rights reserved

9 B-Tree Insertion Mark Allen Weiss
Data Structures and Algorithms in Java (c) 2006 Pearson Education, Inc. All rights reserved

10 B-Tree Insertion Mark Allen Weiss
Data Structures and Algorithms in Java (c) 2006 Pearson Education, Inc. All rights reserved

11 B-Tree Deletion Mark Allen Weiss
Data Structures and Algorithms in Java (c) 2006 Pearson Education, Inc. All rights reserved

12 Price per Megabyte of DRAM
Operating Systems Concepts, 9th edition Silberschatz, Galvin, and Gagne (c) 2013 John Wiley & Sons. All rights reserved

13 Price per Megabyte of Magnetic Hard Disk
Operating Systems Concepts, 9th edition Silberschatz, Galvin, and Gagne (c) 2013 John Wiley & Sons. All rights reserved

14 RAID II Prototype (FrankenRAID) Computer History Museum
Redundant Array of Independent Disks Initially, Redundant Array of Inexpensive Disks Term was coined in 1987 by David Patterson, Randy Katz and Garth A. Gibson. RAID II Prototype (FrankenRAID) Computer History Museum

15 RAID Redundancy RAID increases reliability by adding redundancy.
Mirroring Maintain multiple copies of data. Striping Spread data blocks of a file across multiple disks. Error correcting codes (ECC) Use parity bits and checksums. Recover lost data.

16 RAID Levels Different levels of RAID have different levels of reliability and performance costs. RAID levels 0 through 6 RAID level 1+0 or 10 Example: 4 disks of data C: copy of the data P: error-correcting bits Operating Systems Concepts, 9th edition Silberschatz, Galvin, and Gagne (c) 2013 John Wiley & Sons. All rights reserved

17 RAID 0 Striped data blocks No mirroring Best performance
No fault tolerance

18 RAID 1 Disk mirroring No striping Improved read performance

19 RAID 2 Striped data blocks Parity information Superseded by RAID 3

20 RAID 3 Cannot overlap I/O.
An I/O operation addresses all the drives at the same time. Best for single-user systems with long record applications. Striped data blocks One drive stores parity information.

21 RAID 4 All writes have to update the parity drive. Large stripes
No overlapped writes.  Large stripes Read entire records from any single drive. Overlapped reads.

22 RAID 5 Poor write performance. Block-level striping Striped parity
Array can function even if one drive fails.

23 RAID 6 Continues to function even if two disks fail simultaneously.
Higher cost per gigabyte and often has slower write performance than RAID 5. Similar to RAID 5. Includes a second parity scheme that is distributed across the drives in the array.

24 RAID 10 (1+0) The data is mirrored and the mirrors are striped.
Higher performance than RAID 1, but at a much higher cost. Combines RAID 1 and RAID 0.

25 RAID Tutorials

26 Solid-State Drives (SSDs)
No moving parts. Fail less often than hard drives. Lessens the need for RAID. Use wear leveling instead for data protection. Each block can tolerate a finite number of program/erase cycles before becoming unreliable. Distribute reads and writes evenly among all the blocks of the device.