Presentation is loading. Please wait.

Presentation is loading. Please wait.

EMI Analysis & Debugging Solution

Similar presentations


Presentation on theme: "EMI Analysis & Debugging Solution"— Presentation transcript:

1 EMI Analysis & Debugging Solution
March 2016 EMI Analysis & Debugging Solution

2 Core Technology 20 World Patents on EMC Techniques Since 1999 ~
Filter Design and Analysis Instrument EMI Noise source Separation Instrument Spectrum Analyzer with the noise source Separation Function Since 1999 ~ EMCIS Market Military Aerospace University Research Lab Automotive Telecommunication Semi Conductor 6 Overseas Distributors

3 EMI Analyzer World-FIRST EMI solution provider
Capable of perfect EMI Noise solution Enabling EMI component selection in advance Model : EA-300 Noises from EUT through LISN is displayed on EMI Receiver and the displayed noise is the mixture of Common-Mode(CM) noise and Differential-Mode(DM) noise. Because two different type of noises are shown as the mixed results, it is not-an-easy target to reach EMI solution(debugging)., causing a lot of time and effort (Try and Error) By measuring and analyzing each noise (CM & DM) respectively, the approach to the solution can be clearly correct and accurate path. The solution results – in general, EMI Filters - can be designed easier, quicker and in accurate performance Furthermore, the solution is possible to be proved by theoretic and visual data. Key Characteristics of EMI ANALYZER Analyzing EMI noises in characteristics respectively, Common-Mode(CM) and Differential-Mode(DM) EUT Source Impedance Analysis Most powerful EMI Debugging Instruments Components performance Evaluation (Coil and Capacitor) Trial EMI Filter Design and performance simulation Providing Insertion Loss graph of the selected components Theoretic Noise analysis and Solution approach System Configuration Impedance module

4 EMI Analyzer EA-300 EA-2100 EA-100
* 1). EA-2100 ; 4 Front Button Control EA-100 ; 1 Front Button Control

5 Line Impedance Stabilization
DESIGNED TO CISPR REQUIREMENT EMCIS’ OWN UNIQUE FUNCTION (Test & Analysis mode) Characteristics Specification EUT EMI Analyzer Spectrum Analyzer LISN LN2-16N Frequency Range 9kHz~30MHz Artificial Hand Yes Supply Line/Phase 2 / 1 Network 50Ω / 50uH+5Ω+250uH Inductance 16A Max. Voltage 250V Power frequency DC~60Hz Output mode Test, Analysis RF output BNC 50Ω Phase / Lines 1/2 Dimension W355 D145 H325 (mm) Weight 10.5 kg LISN(Line Impedance Stabilization Network) is used in test of Conducted Emission noise measurement, carrying noises generated from power line, to EMI receiver. LISN supply the power to EUT ; isolates the EUT from interference from external power source ; stabilizes the line impedance ; provides a 50Ohm RF output for connecting it to EMI receiver. Design equal circuits per lines (Live and Neural in single phase) Satisfy CISPR requirements. As EMCIS’ own unique function, LISN has the two different mode selection, Test mode(L1 & L2) and Analysis mode (Common-Mode & Differential-Mode). Test mode is for same application as conventional LISN and Analysis mode is for application combined with EA-2100, DM and CM mode noise separation. Front control panel

6 Line Impedance Stabilization
CISPR CISPR 25 Vehicle LN4-50N / 100A LN1-100C MODEL LN4-50 LN4-100 Frequency Range 9kHz~30MHz Power in/output Terminal Type Artificial Hand 220pF +510Ω Supply Line/Phase 4 / 3 Network Inductance 50Ω/50uH + 5Ω ±20% Coupling Capacitor 0.25uF Max. Current 50A 100A Max. Voltage AC 60Hz : 380V DC : 530V AC 400Hz : 75V Line to Earth Power frequency DC~60Hz, 400Hz Output mode Test, Analysis RF output BNC 50Ω Phase / Lines 3/4 Dimension W705 D500 H261 (mm) W720 D634 H242 (mm) Weight 60 kg 50 kg Frequency Range 150kHz~108MHz Max. Voltage DC 600V, AC 250V 60Hz Max. Current 100A Network 50Ω / 5uH+1Ω Supply Line / Phase 2 / 1 Impedance Tolerance ± 20% Phase Tolerance ± 11.5° RF Output Connector N type 50Ω Female Dimension W139 D308 H118 (mm) Weight 4.3 kg Analysis control panel Hand-hold type In/Output connection

7 Hand-hold type In/Output connection
Line Impedance Stabilization MIL-STD-461E/F CISPR LN1-50 / 100 LN2-50N / 100A MODEL LN1-50 LN1-100 Frequency Range 10kHz~10MHz Power in/output Terminal Type Supply Line/Phase 2 / 1 Network Inductance 50Ω/50uH + 5Ω ±20% Coupling Capacitor 0.25uF Max. Current 50A 100A Max. Voltage AC 60Hz 440V DC 530V AC 400Hz 115V(Line to Earth) Power frequency DC~400Hz Output mode Test, Analysis RF output N-Type 50Ω Dimension W400 D500 H280 (mm) W420 D520 H300 (mm) Weight 10.5 kg 13.8 kg MODEL LN2-50N LN2-100A Frequency Range 9kHz~30MHz Power in/output Terminal Type Artificial Hand 220pF +510Ω Supply Line/Phase 2 / 1 Network Inductance 50Ω/50uH + 5Ω + 250uH Coupling Capacitor 0.25uF Max. Current 50A 100A Max. Voltage AC 250V Power frequency DC~60Hz Output mode Test, Analysis RF output BNC 50Ω Dimension W300 D705 H262 (mm) W350 D530 H241 (mm) Weight 30 kg 28 kg front control Hand-hold type In/Output connection

8 DC–LISN for Photovoltaic Inverter
Switch for Network-V-Y-Delta type Continuous DC 100A Dual Line Characteristics Specially design for Solar Power system application, using in test of Conducted Emission noise measurement, carrying noises generated from power line, to EMI receiver. LISN supply DC power to GCPC ; isolates the EUT from interference from external power source ; stabilizes the line impedance Design equal circuits per lines (Live and Neural in single phase) Operation continuously in Dual Line-100A Satisfy CISPR requirements. As EMCIS’ own unique function, LISN has the two different mode selection, Test mode(L1 & L2) and Analysis mode (Common-Mode & Differential-Mode). Test mode is for same application as conventional LISN and Analysis mode is for application combined with EA-2100, DM and CM mode noise separation. LN2 – 100T Specification Frequency Range 150kHz~30MHz In/Out Connector Terminal-type Supply Line 2 Network Impedance CM:150Ω±20Ω, DM:100Ω±20Ω Phase 0°±40° Insertion Loss > 20dB (EUT~AE) LCL > 26dB Voltage Division Factor 20dB±2dB Max Current 100A Max Voltage DC1500V Mode Selector L1, L2, CM, DM RF Output N-type Dimension W355 D143 H320 (mm) Weight 10.5 kg

9 FILTER ANALYZER FA-300 CISPR17 and/or MIL-STD-220B Measurement
Analysis of EMI Filter Characteristics(Auto) CISPR17 and/or MIL-STD-220B Measurement Spectrum Analyzer installed Frequency Range : 9kHz – 300MHz Characteristics Specification EMI Filter Characteristics Analysis Filter Spec and Quality Control Measure and Analyze CM and DM mode function Attenuation Capabilities Check Satisfy CISPR17 and MIL-STD-200B measurement Data Load/Upload/Edit function Test Report Saving Easy and simple design in operation process – Wide Display & Touch Screen Extended application for components measurement Mostly powerful instruments for Filter Manufacturer Display screen Filter Test Specification subjects to change without notice

10 Characteristics of Differential-mode Filter
Filter Analyzer FA-2100 EMI Filter Characteristics Analysis CISPR17 and/or MIL-STD-220B Measurement Frequency range 10kHz ~ 300MHz Characteristics Specification EMI Filter Characteristics Analysis - Filter spec and quality control Measuring and analyzing DM and CM mode function and attenuation capabilities of EMI filters. Analyze attenuation characteristics of each components like Inductors, Choke Coil, X-Capacitors, Y-Capacitors Using combined with Network Analyzer and/orSpectrum analyzer equipped Tracking Generator CISPR17 and/or MIL-STD-220B Measurement Frequency range from 10kHz to 300MHz Easy and simple design in operation process –front display panel and push-button Frequency Range 10kHz ~ 300MHz Mode Selector CISPR17 .MIL-STD-220B Test Mode Differential , Common Signal loss 10kHz~30MHz < 3dB 30MHz~300MHz < 5dB CM/DM Separation 10kHz~30MHz < 40dB 30MHz~300MHz < 30dB Input sensitivity -97dBm (10dBuV) Max RF Input 23dBm (130dBuV) Filter Input / Output 2 SMA Connector Display Front panel VFD display Front panel control 4 Button control Input impedance 50Ω Input Dynamic Range 120dB Connector BNC 50Ω Test Table (FA-001) Slide Door Input Voltage AC100V~ 240V 50/60Hz 10W Dimension W365 D330 H150 (mm) Test Table - Specifications subjects to change without notices Characteristics of Differential-mode Filter

11 Conducted Reference Source
CRS-1530 Providing reference source Avoiding measurement errors Comparing measurement site circumstance (EMC Lab ) Characteristics Reference Signal Provides Reference sources to measuring instruments checking set-up defaults conditions of LISN, cables, etc. Avoids, in advance, any uncertainty in measurements, causing measurement errors Usable without changing of set-up condition on EMI measurement Application * Authorized EMC Lab * Private EMC Lab * Research Lab/institutes * University/Colleges * Industries * Others Specification Frequency Range 150kHz~30MHz Power DC 12V Battery Output Level 50dBuV ±3dBuV Frequency stability Quartz drive Low Voltage Detection Buzzer Power Indicator LED Operating Temp range 15℃ ~ 55℃ Dimension W65 D65 H120 (mm) Weight 300 g Connection Spectrum Analyzer or EMI Receiver CRS-1530 LISN - Specifications subjects to change without notices

12 Multi Power Line Interference Probe
MP-930 Usable on both power source, AC/DC Easy measurements on power line and the path noises Characteristics Specification Capable to measure noise level at each line-end. Capable to use on standard 440V 3Ph AC line, max 275VAC(rms) between line and ground, both AC/DC. Measurable from 9kHzto 30MHz, without RF Amp Useful when EUT is required high current ; when the measuring circumstance is not easy to use LISN Usable with Spectrum analyzer Minimizing the possible tolerance in low frequency noises, by adopting HPF(High Pass Filter). Frequency Range 9kHz ~ 30MHz Input voltage AC220V 50/60Hz, DC380V Input current 63mA AC50Hz(nom) 0.8mA DC max Input dynamic range 70dB Insertion loss 100kHz~30MHz 2dB Output connector BNC Test Voltage DC1500V Temperature range -5°C to 55°C Relative humidity 20% to 80% Dimension W38 D23 H9 (mm) Test Table 2.6 kg System Set-up With EMI Analyzer MP-930 EMI Analyzer (EA-2100) Spectrum Analyzer L1 GND L2 Insertion Loss Capable to analyze/measure Total, DM, CM noises and their levels. With Spectrum Analyzer/ Receiver MP-930 Spectrum Analyzer L1 GND L2 Connecting with Line1, Line 2 and measure total noise level – only possible to measure total noise - Specifications subjects to change without notices

13 DC Bias Source DCS - 50D Characteristics Specification
Analysis of Inductor and/or Transformer functional characteristics Digital control from 0~20A, at 10mA step Optional extended range from 10kHz~30MHz. Use with Impedance Analyzer or LCR Meter. Attenuation measurement (Max. 100MHz) Suitable Inductor and/or Transformer design. Useful in quality control. MODEL DBS-50D Frequency Range L , Z : 10kHz~30MHz Attenuation : 10kHz~100MHz Current Range 0~50A Steps of 10mA Measured L , Z Attenuation Power Supply AC 220V 60Hz Coupling Capacitor 0~35°C Dimension W530 D539 H215(mm) Weight 58 kg Accessories DBS-03CB, SMA-MM-400, DBS-03CL (10kHz ~ 5MHz) DBS-03EB, N20-MM-600, DBS-03EL (10kHz ~ 30MHz) DBS-003A : Attenuation measurement (10kHz ~ 100MHz) BNC-MM-1000 : BNC to BNC Cable (1m) DBS-Terminal : Terminal type DBS-SMD : SMD measurement Note : - L, Z measurement : using with LCR Meter , Impedance Analyzer - Attenuation : Spectrum Analyzer ,Network Analyzer System configuration LCR Meter or Impedance Analyzer DC Bias Source Adaptor DUT - 13 -

14 DC Bias Source DBS-20D/50D System Configuration Accessories LCR Meter
Impedance Analyzer Accessories DBS-03CB 400mm DBS-03CL 10kHz~5MHz Measurement Accessories DBS-03EB N20-MM-600 DBS-03EL 10kHz~30MHz Measurement Accessories DBS-003A (Attenualtion) BNC-MM (1m) DBS-Terminal, DBS-SMD - 14 -

15 EMI Filter Excellent filtering characteristics
EMCIS designs and supplies the Accurate filters what customers want, using EMCIS’ own measuring Instruments and software. No limit on application ; Industrial, Telecommunication, Military, Automotive DC~AC 440V 1Ph, 3Ph, 1A~400A , 10KHz~ 10GHz


Download ppt "EMI Analysis & Debugging Solution"

Similar presentations