Presentation is loading. Please wait.

Presentation is loading. Please wait.

Engineering and Manufacturing Specialty HVAC Equipment since 1971

Similar presentations


Presentation on theme: "Engineering and Manufacturing Specialty HVAC Equipment since 1971"— Presentation transcript:

1 Engineering and Manufacturing Specialty HVAC Equipment since 1971
4500 Industrial Access Road Douglasville, GA ; P

2 Two adjacent manufacturing facilities.
Over 200,000 square feet of floor space 4500 Industrial Access Road Douglasville, GA ; P

3 150 to 200 dedicated employees
4500 Industrial Access Road Douglasville, GA ; P

4 Employee owned company
4500 Industrial Access Road Douglasville, GA ; P

5 Welded formed galvanized steel base
4500 Industrial Access Road Douglasville, GA ; P

6 Welded extruded aluminum base
4500 Industrial Access Road Douglasville, GA ; P

7 12 inch welded structural steel base
4500 Industrial Access Road Douglasville, GA ; P

8 1” 3lb. and 4” batt type insulation or sprayed with up to 6” inches of polyurethane foam insulation.
4500 Industrial Access Road Douglasville, GA ; P

9 Fiberglass insulation R value 4.3 inch
Polyurethane foam injected insulation R value 6.7 per inch 4500 Industrial Access Road Douglasville, GA ; P

10 Panels are insulated with 2”, 3” or 4” double wall fiberglass or polyurethane foam insulation.
4500 Industrial Access Road Douglasville, GA ; P

11 Seasons-4 units feature an aluminum casing that never needs painting and will not rust.
4500 Industrial Access Road Douglasville, GA ; P

12 Galvanized Steel and Stainless Steel casing are also available.
4500 Industrial Access Road Douglasville, GA ; P

13 Standard Available Colors
4500 Industrial Access Road Douglasville, GA ; P

14 Custom Colors Yellow Red
4500 Industrial Access Road Douglasville, GA ; P

15 Full-height access doors feature full-length continuous hinges, stainless steel hold-backs, rain gutters and single door handle with multiple point latches. 4500 Industrial Access Road Douglasville, GA ; P

16 Air Cooled Condensing Sections
4500 Industrial Access Road Douglasville, GA ; P

17 550 tons of air cooled packaged unit
4500 Industrial Access Road Douglasville, GA ; P

18 Air Cooled Condensing Sections with expanded aluminum guards
4500 Industrial Access Road Douglasville, GA ; P

19 Air Cooled Condensing Sections with sound attenuators & louvers
4500 Industrial Access Road Douglasville, GA ; P

20 EC motors Air Cooled Condensing Sections with:
4500 Industrial Access Road Douglasville, GA ; P

21 Evaporative-Cooled Condensing Sections
4500 Industrial Access Road Douglasville, GA ; P

22 Water-Cooled w/Shell & Tube Condensers
4500 Industrial Access Road Douglasville, GA ; P

23 Water-Cooled w/Plate-type Condensers

24 Chilled water, Hot water or Steam coils with copper fins or Electro-Fin coated.
4500 Industrial Access Road Douglasville, GA ; P

25 Copeland Scroll™ Digital Technology
10-100% Capacity Modulation Effective Way To Achieve Infinite Capacity Modulation Available in 4 to 15 HP Models Compressor Controller monitors the cooling demand by modulating the solenoid valve Diagnostics-7 codes indicating faults Protection against excessive discharge temperature, low flow conditions and operation under fault conditions. 4500 Industrial Access Road Douglasville, GA ; P

26 Seasons-4 uses Copeland semi-hermetic reciprocating compressors to deliver 5 to 300+ tons of cooling capacity. 4500 Industrial Access Road Douglasville, GA ; P

27 Hermetic screw compressors.
4500 Industrial Access Road Douglasville, GA ; P

28 Seasons-4 offers HCFC- free refrigerants
R-407c R-134a R-410a R-22 R-22 will be phased-out by 2010 in new equipments and production must end by 2020. 4500 Industrial Access Road Douglasville, GA ; P

29

30 High efficiency SWSI backward inclined, airfoil plenum belt driven or direct drive supply air blowers with premium efficiency motors, mounted on 2” deflection spring isolators. 4500 Industrial Access Road Douglasville, GA ; P

31 High efficiency DWDI backward inclined, airfoil housed blowers
4500 Industrial Access Road Douglasville, GA ; P

32 Axial fans with roll-out carts
4500 Industrial Access Road Douglasville, GA ; P

33 Multiple fan arrangements
4500 Industrial Access Road Douglasville, GA ; P

34 Indirect natural gas or propane gas tubular duct furnaces with stainless steel heat exchangers
4500 Industrial Access Road Douglasville, GA ; P

35 Indirect natural gas or propane gas power burners with stainless steel drum and tube heat exchangers
4500 Industrial Access Road Douglasville, GA ; P

36 Seasons-4 Energy Recovery Systems
Energy recovery can substantially reduce mechanical heating and cooling requirements associated with conditioning ventilation air in most buildings, specially buildings require 100% outside air at high ventilation rates. Seasons-4 offers the most commonly used energy recovery systems. 1- Energy Recovery Wheels a) Enthalpy Wheels b) Sensible Wheels c) Desiccant Wheels 3- Heat Pipes 4- Run-Around Loops 2- Air to Air fixed flat Heat Exchangers 1

37 Energy Recovery Wheels:
Energy recovery wheels are the most efficient energy recovery devices, effectiveness ranging from 50% to 80%. The wheels require routine maintenance of the belt and the motor and good filtration. Exhaust Air Fresh Air Supply Air Return Air

38 Heat pipe

39 Energy Recovery units with an Enthalpy wheel and a Sensible wheel in each unit.

40 FIXED-FLAT HEAT EXCHANGERS
Plate heat exchanger are the second most efficient energy recovery systems, effectiveness ranging from 50% to 75%. Their most distinct advantage is that they have no moving parts. Return Air Supply Air Fresh Air Exhaust Air

41

42

43

44

45 Heat Pipe Heat Exchangers:
Heat pipe heat exchangers have the appearance of ordinary finned coils with specific amount of refrigerant . Effectiveness between 50% to 65%. Because they lack moving parts, Heat Pipes are low maintenance and very rarely fail. Supply Air Return Air Exhaust Air Fresh Air

46 Flat Heat pipe

47 Wrap around Heat pipe

48 Run-Around Loops: Run-Around Loops, also known as coil energy recovery loops, use a coil placed in each air stream that are connected by pipes filled with a heat transfer fluid, generally a glycol Solution. Effectiveness ranging from 50% to 65%. Coil Fan Supply air Fresh Air Coil Fan Exhaust Air Pump Tank Return Air 2

49 Walk in Service Vestibule
4500 Industrial Access Road Douglasville, GA ; P

50 Walk in Service Corridors
4500 Industrial Access Road Douglasville, GA ; P

51 Walk in Service Corridors
4500 Industrial Access Road Douglasville, GA ; P

52 Network Integration You’re Covered. The Bottom Line,
no matter what BAS… Modbus N2 Bus BACnet LonWorks Network Interface card required You’re Covered. a Division of Automated Logic Corp.

53 Low Temperature Applications
Seasons-4 also offers DX units to deliver 39°Fdp discharge air for critical food processing and dehumidification applications. 4500 Industrial Access Road Douglasville, GA ; P

54 Dual Path Systems For Absolute dehumidification
Outside air Outside air coil 95/78 deg F. 55/54 deg F. LAT Reheat coil Return air Return air coil 75/63 deg F 55/54 deg F. LAT 4500 Industrial Access Road Douglasville, GA ; P

55 Multi-zone Triple Deck Systems
Constant volume or VAV . HOT DECK HOT DECK COLD DECK COLD DECK 4500 Industrial Access Road Douglasville, GA ; P

56 Multi-zone Triple Deck Systems
Constant volume or VAV . HOT DECK SA BLOWER BYPASS COLD DECK 4500 Industrial Access Road Douglasville, GA ; P

57 Modified portable container with energy wheel and air cooled condensing section
4500 Industrial Access Road Douglasville, GA ; P

58

59

60

61

62

63

64

65

66 8-Hour Installation Leader in Direct replacement of Multi-zone, Single zone, Rooftop and Indoor units Lennox AAF ECS Nesbitt Trane Dunham Bush Carrier York Acme Mammoth Governaire Schemenauer McQuay Webster Pace Air-Dyne Marlo Miller Picking Tjernlnd Des Champs Jackson & Church …and many more 4500 Industrial Access Road Douglasville, GA ; P

67 A factory specialist measures the existing unit length, width, zones and utilities locations.
4500 Industrial Access Road Douglasville, GA ; P

68 The existing unit is removed
4500 Industrial Access Road Douglasville, GA ; P

69 The existing unit curb is cleaned and covered with factory provided gasket.
4500 Industrial Access Road Douglasville, GA ; P

70 Existing curb and utility connections are prepared for the new unit.
4500 Industrial Access Road Douglasville, GA ; P

71 Units are built, factory tested and shipped…….
4500 Industrial Access Road Douglasville, GA ; P

72 The new direct replacement unit is rigged onto the existing curb.
4500 Industrial Access Road Douglasville, GA ; P

73 The end panel is removed to match the existing zones.
4500 Industrial Access Road Douglasville, GA ; P

74 The utility connections and all the zones are matched and the unit is ready for start up.
4500 Industrial Access Road Douglasville, GA ; P

75 The utility connections and all the zones are matched and the unit is ready for start up.
4500 Industrial Access Road Douglasville, GA ; P

76 Leader in direct replacements of Multi-zone or Single zone units.
Existing Lennox unit Seasons-4 Direct Replacement 4500 Industrial Access Road Douglasville, GA ; P

77 Existing York unit Seasons-4 Direct Replacement
Leader in Direct Replacements of Multi-zone or Single zone units. Existing York unit Seasons-4 Direct Replacement 4500 Industrial Access Road Douglasville, GA ; P

78 Carrier Single zone unit Seasons-4 Direct Replacement
Leader in Direct Replacement of Multi-zone or Single zone units Carrier Single zone unit Seasons-4 Direct Replacement 4500 Industrial Access Road Douglasville, GA ; P

79 McQuay Single zone unit Seasons-4 Direct Replacement
Leader in Direct Replacement of Multi-zone or Single zone units McQuay Single zone unit Seasons-4 Direct Replacement with curb adaptor 4500 Industrial Access Road Douglasville, GA ; P

80 Existing roof built unit Seasons-4 Direct Replacement
Leader in Direct Replacement of Multi-zone or Single zone units Existing roof built unit Seasons-4 Direct Replacement 4500 Industrial Access Road Douglasville, GA ; P

81 Leader in Direct Replacement of Multi-zone or Single zone units
We can help you replace a “roof-made” unit with a custom designed, factory manufactured and tested Seasons-4 unit. 4500 Industrial Access Road Douglasville, GA ; P

82 Leader in Direct Replacement of Multi-zone or Single zone units
We can help you replace a “man-made” unit with a custom designed, factory manufactured and tested Seasons-4 unit. 4500 Industrial Access Road Douglasville, GA ; P

83 Leader in Direct Replacement of Multi-zone or Single zone units
1 3 2 Precise engineering, job site delivery, rigging assistance and supervision of start up are provided by Seasons-4. 4500 Industrial Access Road Douglasville, GA ; P

84 Custom designed air cooled condensing sections
4500 Industrial Access Road Douglasville, GA ; P

85 A Custom replacement unit is positioned carefully into place, saving
the owner money and the contractor valuable time. SEASONS-4’s Custom HVAC Unit Engineering and Manufacturing help customers get their job done on time. 4500 Industrial Access Road Douglasville, GA ; P

86 Every Seasons-4 unit is run-tested at our factory prior to shipment and delivered to the job site at the requested date and time. Seasons-4 provides factory rigging and start-up assistance. 4500 Industrial Access Road Douglasville, GA ; P

87 Seasons-4 is the primary manufacturer for
Los Angeles Unified School District (L.A.U.S.D) 10 years. Hacienda La Puente Unified School District, LA County. San Diego City USD. New York City School Construction Authority (NYCSA). Fairfax County School District in Virginia,. P.S. Business Office Buildings, Maryland. Department Of Motor Vehicles , California. Brandywine Realty, New Jersey . Cherry Creek School District, Colorado. Supermarkets: Food City, Safeway, Stater Brothers, HY VEE, Whole Foods, Wal Mart Super centers, Target Super Centers, SHAWS, Weis Market, Stop & Shop, Giant Eagle, Giant Foods, SAMS, Harris Teeters, Martins, Dierbergs, Redners, Wild Oats, Woodmans 4500 Industrial Access Road Douglasville, GA ; P


Download ppt "Engineering and Manufacturing Specialty HVAC Equipment since 1971"

Similar presentations