Presentation is loading. Please wait.

Presentation is loading. Please wait.

RS3-FIM series Migration Don't let wiring costs prevent you from upgrading an RS3 FIM series system to a DeltaV system This document is the property of.

Similar presentations


Presentation on theme: "RS3-FIM series Migration Don't let wiring costs prevent you from upgrading an RS3 FIM series system to a DeltaV system This document is the property of."— Presentation transcript:

1 RS3-FIM series Migration Don't let wiring costs prevent you from upgrading an RS3 FIM series system to a DeltaV system This document is the property of Firelec. No copy, even partial, allowed without prior writen authorization.

2 RS3-FIM series Migration Using RIAs (RS3 Interface Adapters) : Keeping existing I/O panels Keeping I/O termination panels and associated process I/Os Installing RIAs (RS3 Interface Adapters) on existing FIM series termination panels This document is the property of Firelec. No copy, even partial, allowed without prior writen authorization.

3 RS3-FIM series Migration FIM electronic module to be removedRIA to be plugged in place of existing FIM module Using RIAs

4 This document is the property of Firelec. No copy, even partial, allowed without prior writen authorization. RS3-FIM series Migration RS3 ControlFile Primary PeerWay Secondary PeerWay Using RIAs Communication Termination Panel Process I/Os FIMFIM FIMFIM Existing RS3 architecture

5 This document is the property of Firelec. No copy, even partial, allowed without prior writen authorization. RS3-FIM series Migration RS3 ControlFile Primary PeerWay Secondary PeerWay PeerWay to be removed Using RIAs Communication Termination Panel To be removed Process I/Os FIMFIM FIM to be replaced by the RIA Process I/Os FIMFIM FIM to be replaced by the RIA Devices to be removed

6 This document is the property of Firelec. No copy, even partial, allowed without prior writen authorization. RS3-FIM series Migration Using RIAs I/O termination panels and associated I/Os are kept in place in the existing cabinets Process I/Os Devices to be kept

7 This document is the property of Firelec. No copy, even partial, allowed without prior writen authorization. RS3-FIM series Migration Using RIAs Process I/Os New DeltaV architecture Secondary DeltaV Highway Cntrl PS I/O1 I/O2 I/O3 I/O4 I/O5 I/O6I/O7 I/O8 Primary DeltaV Highway

8 RS3-FIM series Migration The End


Download ppt "RS3-FIM series Migration Don't let wiring costs prevent you from upgrading an RS3 FIM series system to a DeltaV system This document is the property of."