E Ethernet C CAN bus P Profibus HV HV cables LV LV cables (+busbar) S Serial (RS232) Signal cable Other/Unknown Liquid or Gas Cable and/or Bus PCI-XYZ.

Similar presentations


Presentation on theme: "E Ethernet C CAN bus P Profibus HV HV cables LV LV cables (+busbar) S Serial (RS232) Signal cable Other/Unknown Liquid or Gas Cable and/or Bus PCI-XYZ."— Presentation transcript:

1 E Ethernet C CAN bus P Profibus HV HV cables LV LV cables (+busbar) S Serial (RS232) Signal cable Other/Unknown Liquid or Gas Cable and/or Bus PCI-XYZ XYZ OPCserver PVSS II OPC client The interface to the equipment (e.g. CAN or Profibus interface). [ethernet interfaces are not indicated] The software interface to the equipment (e.g. commercial OPC server) The software interface at the client side (e.g. OPC client in PVSSII) This depicts a task on a PC, each box does not necessarily correspond to a single PC ISEG 1 This depicts equipment to be controlled. This indicates the number of units (usually crates) This depicts the communication media or type of cable (see table) C 3 This indicates the number of busses or cables Alice Control Room (ACR) Counting Rooms in PX25 (CR1 – CR4) and Plug Cavern, outside L3 magnet Cavern, inside L3 magnet Areas at ALICE Detector HV This depicts the cable from the equipment to the hardware (see table) 3 This indicates the number of cables or channels This depicts the hardware connected Explanation of the detector drawings, field layer

2 CAEN OPCserver PVSS II Wiener OPCserver Ethernet User interface Database(s) OPC client DIM client PVSS II Schneider OPCserver PVSS II OPC client PVSS II OPC client [FSM?] DIMserver This depicts a task on one or more PC’s, there is no one-to- one correspondence between boxes and PC’s User interface; main console for detector operation Main PVSS tasks; interface to field layer, Finite State Machine, … Database tasks (reading and writing). Field layer, with field layer processes “Generic” architecture for the DCS “back end”

3 Detector CAEN PVSS II Ethernet Database(s) OPC client DIM client 1561 High Voltage User interface PVSS II HV V0 Control room (ACR) [FSM?] 28/02/03 Crate Control CAEN OPC server PVSS II OPC client DIMserver ? FEE Front End electronics ? PCI-CAN Wiener OPCserver PVSS II OPC client C VME (wiener?) 4 ?? E PMT Optical fibers

4 V0 (no URD) High Voltage Power supplies : CAEN SY1527 (13 boards A1733N) 1500 – 2000V, 156 channels (144 in use + 12 spares) HV cable : 156 cables : type SHV Cables do not enter the magnet ; PMT located in the same rack that the HV supply. FEE Control discriminators setup and delay ⇒ ~ 900 parameters Access through a VME master ? Crate/Equipment Control (?) VME crates - exact number and type to be decided Any other system (calibration, alignment, …)? Calibration using LED or laser (system and procedure to be defined) Racks : 2 racks have been allocated (one at each side of magnet) : see C. Gregory Optical fibers path inside the magnet : 4 rails of fibers (section of 50 x 30 mm each) for each side : see C. Gregory for exact path

5 V0 – Localisation

6 V0 - Front End Electronics Control of the discriminators (threshold and width) Control of various delays Choice between different trigger configurations (pp or AA channels) x 144 x 2 x 12 x 2 ⇒ ~ 900 parameters