Update on the CNI polarimeter results for Run02 1.Bunch-by-bunch polarization study 2.Profiles of 0-pol bunches Osamu Jinnouchi.

Slides:



Advertisements
Similar presentations
2010 PREx Run – Dithering & Compton Polarimetry Chun-Min Jen on behalf of the Hall-A JLab. Institution: Syracuse University, NY, 13244,
Advertisements

AGS Status and Plans RHIC Spin Collaboration Meeting 2/4/11.
Beam direction and flux measured by MUMON K. Matsuoka (Kyoto) for the MUMON group Contents: 1.Beam stability (direction/flux) 2.Absolute  beam flux.
PHENIX local RUN9 RHIC meeting Manabu Togawa for the PHENIX 1.
APEX Report April 28-29, 2009 May 4, 2009 Fulvia Pilat Time Meeting, May
RHIC/AGS Polarimeter Study May 1, 2009 H. Huang, A. Zelesnki, B. Morozov.
Run 11 as run 3 Jan, Begin cool-down to 4.5K 8 Jan, Cool-down to 4.5K complete in both rings, preliminary setup begins 24 Jan, 1 week Ramp-up with 8 hr/night.
RUN 11 RHIC MACHINE/EXPERIMENTS MEETING 5 Apr 2011 Agenda: Open.
Run 12 RHIC Machine/Experiments Meeting 29 Jun 2012 Run 12 Summary Slides.
The polarized hydrogen jet target measurements at RHIC Andrei Poblaguev Brookhaven National Laboratory The RHIC/AGS Polarimetry Group: I. Alekseev, E.
Polarimetry of Proton Beams at RHIC A.Bazilevsky Summer Students Lectures June 17, 2010.
E.C. Aschenauer RSC-Meeting, January 21st T h e b e s t k e p t s e c r e t n u m b e r a t R H I C / B N L / U S A f o r s u r e n o t t o b e.
Time Meeting PHENIX Run-15 Status Douglas Fields PHENIX Run-15 Run Coordinator University of New Mexico.
Thomas Roser Snowmass 2001 June 30 - July 21, 2001 Polarized Proton Acceleration and Collisions Spin dynamics and Siberian Snakes Polarized proton acceleration.
October 4-5, Electron Lens Beam Physics Overview Yun Luo for RHIC e-lens team October 4-5, 2010 Electron Lens.
Run 8 Polarization measurements from STAR BBC Andrew Gordon September 12, 2008.
PHENIX Local Polarimeter PSTP 2007 at BNL September 11, 2007 Yuji Goto (RIKEN/RBRC)
Systematic Errors Studies in the RHIC/AGS Proton-Carbon CNI Polarimeters Andrei Poblaguev Brookhaven National Laboratory The RHIC/AGS Polarimetry Group:
Polarized beam in RHIC in Run Polarimetry at RHIC A.Zelenski, BNL PSTP 2011, September 13, St.Petersburg.
October 14, 2004 Single Spin Asymmetries 1 Single Spin Asymmetries for charged pions. Overview  One physics slide  What is measured, kinematic variables.
K.O. Eyser --- Absolute Polarization Measurement at RHIC in the Coulomb Nuclear Interference Region -1- Absolute Polarization Measurement at RHIC in the.
Relative Polarization Measurements of Proton Beams Using Thin Carbon Targets at RHIC Grant Webb Brookhaven National Laboratory Sept 14, 2015PSTP20151 for.
Polarization Measurements of RHIC-pp RUN05 Using CNI pC-Polarimeter Itaru Nakagawa (RIKEN/RBRC) On behalf of CNI Polarimeter Group I.G.Alekseev A A.Bravar.
Stephen Trentalange UCLA DIS04 1 Inclusive Jet Asymmetries from STAR Analysis Update Stephen Trentalange for the STAR Collaboration.
» Absolute Polarimetry of Proton Beams at RHIC« Oleg Eyser for the RHIC Polarimetry Group International Workshop on Polarized Sources, Targets and Polarimetry.
RUN 11 RHIC MACHINE/EXPERIMENTS MEETING 12 Apr 2011 Agenda: Open.
» RHIC Polarimetry « Oleg Eyser for the RHIC Polarimetry Group 2014 RHIC Retreat, August 14.
RUN 11 RHIC MACHINE/EXPERIMENTS MEETING 14 Mar 2011 Agenda: Status – cryo/budget Experiment priorities.
1 RHIC Machine/Detector Planning Meeting 29 Jan 08 Agenda –Run 8 end game issues, if any Planning Meeting Web Site:
Proton Polarimetry at RHIC K. Oleg Eyser for the CNI polarimeter group Newport News, VA, October 25, 2013.
RHIC Run11 Summary May 6, 2011 RSC Meeting Haixin Huang Luminosity Availability Polarization RHIC setup issues.
A. Zelenski a, G. Atoian a *, A. Bogdanov b, D.Raparia a, M.Runtso b, D. Steski a, V. Zajic a a Brookhaven National Laboratory, Upton, NY, 11973, USA b.
Run 12 RHIC Machine/Experiments Meeting 17 Apr 2012 Agenda: Status reports Polarization issues update (E. Aschenauer) Other business With 17 April update.
Run6 CNI Analysis: Concluding Remarks and Summary of Systematic Uncertainties A.Bazilevsky For RHIC CNI group RHIC Spin Collaboration Meeting November.
POLARIZATION MEASUREMENTS AND ABSOLUTE POLARIZATION VALUES EVOLUTION DURING PROTON BEAM ACCELERATION IN THE RHIC ACCELERATOR COMPLEX A.Zelenski, T.Roser,
N. Poljak, FPD++ N. Poljak, U. of Zagreb.
IHEP/Protvino for FP420 R&D Collaboration 1 IHEP/Protvino Group: Igor Azhgirey Igor Bayshev Igor Kurochkin + one post-graduate student Tools:
Jin Huang M.I.T. For Transversity Collaboration Meeting Jan 29, JLab.
Orbit related issues of the spin tune control at RHIC V.Ptitsyn, M.Bai, W.MacKay, T.Roser.
E.C. Aschenauer STAR Spin PWG 2012/03/222  Known complications:  100 GeV: o noise due to pickup especially at injection less significant at flat top.
RHIC CNI Polarimeter status RHIC CNI Group February 26, 2008.
versus Proton spin vector Double-spin helicity asymmetry: N ++ / L ++  N +  / L +  N ++ / L ++ + N +  / L +  1 P1P2P1P2P1P2P1P2 A LL  Single-spin.
P-Carbon CNI polarimeter upgrades. Vacuum system. Target drives. Targets. Polarimetry Workshop, July 31, 2009 A.Zelenski for polarimetry group.
Thomas Roser Snowmass 2001 June 30 - July 21, 2001 Proton Polarimetry Proton polarimeter reactions RHIC polarimeters.
Absolute Polarization Measurement at RHIC in the Coulomb Nuclear Interference Region September 30, 2006 RHIC Spin Collaboration Meeting RIKEN, Wako, Japan.
October 22, 2004 Single Spin Asymmetries at RHIC 1 F.Videbaek Physics Department, Brookhaven National.
Polarized Proton at RHIC: Status and Future Plan Mei Bai Collider Accelerator Dept. BNL A Special Beam Physics Symposium in Honor of Yaroslav Derbenev's.
Inclusive cross section and single transverse-spin asymmetry of very forward neutron production at PHENIX Spin2012 in Dubna September 17 th, 2012 Yuji.
RHIC Polarimetery A.Bazilevsky for RHIC Polarimetry group RHIC Spin Collaboration Metting April 10 (Friday), 2009.
RHIC pC polarimeter what has been achieved and what needs to be done Osamu Jinnouchi RBRC 2/10/05 RSC meeting.
RUN 11 RHIC MACHINE/EXPERIMENTS MEETING 7 Jun 2011 Agenda: √s = 200 GeV AuAu progress 27 GeV Run (or other)
RUN 11 RHIC MACHINE/EXPERIMENTS MEETING 31 May 2011 Agenda: √s = 200 GeV AuAu progress Update on 250 GeV integrated Lumi.
RHIC pC Polarimeters in Run9: Performance and Issues A.Bazilevsky for the RHIC CNI Group Polarimetry Worshop BNL, July 31, 2009.
CNI polarizations in Run09: Summary A.Bazilevsky For the RHIC CNI Group March 26, 2010 RSC meeting.
RUN 11 RHIC MACHINE/EXPERIMENTS MEETING 14 Jun 2011 Agenda: √s = 200 GeV AuAu progress ZDC Calibration for AnDY – the plan Request from AnDY √s = 27 GeV.
AGS FY11 Summary RHIC Spin Collaboration Meeting 5/6/11.
RUN 11 RHIC MACHINE/EXPERIMENTS MEETING 29 Mar 2011 Agenda: Open.
RUN 11 RHIC MACHINE/EXPERIMENTS MEETING 22 Mar 2011 Agenda: Open.
1 Local Polarimetry for Proton Beams with the STAR Beam Beam Counters Joanna Kiryluk Massachusetts Institute of Technology for the STAR Collaboration SPIN2004.
Possible Run 10 plan based on 25 Nov Revised Plan Run10, 25 cryo-weeks (my guesses after Jan 12) – Dec. 1, Begin cool down to 4.5K – Dec. 4, Cooldown to.
1 Single spin asymmetry of forward neutron at PHENIX. 2005/06/02 RBRC workshop "Single-Spin Asymmetries" Manabu Togawa Kyoto-University, RIKEN.
RHIC pC Polarimeter status A.Bazilevsky For RHIC CNI Group February 26, 2008.
Kieran Boyle (Stony Brook University) for the PHENIX Collaboration
Yuxi Pan University of California, Los Angeles
2006 Relative Luminosity Tai Sakuma MIT 4/5/2007
2006 Relative Luminosity Tai Sakuma MIT 3/19/2007.
ILC Baseline Design: Physics with Polarized Positrons
The Fill Pattern for 2006 Tai Sakuma
Run5 Analysis of RHIC-pC Polarimeter
p0 ALL analysis in PHENIX
Presentation transcript:

Update on the CNI polarimeter results for Run02 1.Bunch-by-bunch polarization study 2.Profiles of 0-pol bunches Osamu Jinnouchi

5/22/2002RHIC Spin Collaboration Meeting2 1. Bunch by bunch polarization study  Interests for spin physics analysis  Luminosity weighted polarization info (bunch per bunch polarization) is needed  Each detector sees different bunch combinations (clockwise,anti-clockwise) STAR (i,i+20) 6 o ’ clock PHENIX,pp2pp,BRAHMS (i,i+40) 2 or 8 o ’ clock PHOBOS (i,i) 10 o ’ clock for machine physicists  Bunch profile Is there any weird bunches? Polarization profile within 55-bunches

5/22/2002RHIC Spin Collaboration Meeting3 Polarimeter dedicated run  10 successive measurements at the end of store for both rings (fill ID :2301 Jan. 23th, 02)  The data can be summed up to gain statistics  0-pol bunches are available (3-bunches 1 st,21 st,41 st ) 2min x 10 = 20min measurement

5/22/2002RHIC Spin Collaboration Meeting4 Bunch by bunch asymmetry  Good statistics  Used square-root formula  The values are averages of X90 and X45 1.Origin of gaps 2.Separation of Plus spin and Minus spin  can we trust 0-pol bunches ? Naive calculation shows terrible distributions BLUE YELLOW BUNCH ID Asymmetry x Spin pattern(+1,-1,0) gap separation Up-spin Dn-spin 0-pol

5/22/2002RHIC Spin Collaboration Meeting5 Origin of gaps  Location of the gaps are corresponding to small population bunches  There are hits on the empty bunches (56-60th)  Found out that several strips are noisy 1.Noisy strips can be excluded from calculation 2.How about other normal fills? BLUE BUNCH ID Asymmetry x Spin pattern(+1,-1,0) gap Dedicated run (fill:2301) BUNCH ID Bunch luminosity at RHIC polarimeter Up-spin Dn-spin

5/22/2002RHIC Spin Collaboration Meeting6 Consistency between 0-pol bunches  Triplets turned out to be identical twins (2 nd – 3 rd pair)  Y components are rather large (vertical target)  Generating false asymmetries of comparable size 1.How about other fills? BLUEYELLOW st -2 nd 2 nd -3 rd 3 rd -1 st 1 st -2 nd 2 nd -3 rd 3 rd -1 st X90 X45 Y45 Square-root asymmetries Dedicated run (fill:2301)

5/22/2002RHIC Spin Collaboration Meeting7 Luminosity ratio  Typical run (fill ID:2277)  Supposed to be flat if two bunches are identical  Fit with horizontal line and yield reduced chi-square Si-1 Si-2 Si-3 Si-4 Si-5 Si-6 #1 #2 #3 #4 #5 #6 1 st /2 nd 2 nd /3 rd 3 rd /1 st Count ratio for each detector

5/22/2002RHIC Spin Collaboration Meeting8 Luminosity ratio (cont ’ d)  Reduced Chi-square dists. for all the fills including 0-pol bunches (fill id: 2277~ last)  Generally 1 st 0-pol bunch is strange 1 st /2 nd 2 nd /3 rd 3 rd /1 st

5/22/2002RHIC Spin Collaboration Meeting9 Bunch profile (fill id:2277 last measurement at 100GeV)  Similar analysis applied for polarized bunches  Fitting with Sin function instead of flat constant 1.Luminosity ratio is getting worse at low populated bunches, which would result in false asymmetry 2.Adjacent bunches are also affected 3.Need a criteria to throw away those weird bunches Luminosity of RHIC polarimeter Wall Current Monitor Typical Run

5/22/2002RHIC Spin Collaboration Meeting10 Improved bunch by bunch asymmetry  Exclude noisy strips Gaps disappeared  Use combined 0-pol (2 nd and 3 rd ) Separation disappeared 1.Still some bunches behave strange low populated bunches introduce false asymmetries 2.Tendency up drops and down grows in yellow Need further study Up-spin Dn-spin BLUE YELLOW BUNCH ID Asymmetry x Spin pattern(+1,-1,0) 0-pol Dedicated run (fill:2301)

5/22/2002RHIC Spin Collaboration Meeting11 Summary  1 st 0-pol bunch is strange Tail effect of the kicker field?  Low populated bunches will create false asymmetries Need certain criteria to throw them away (fitting   is a good candidate)