FIGURE 7. 1 Morphology on Feeder Layers

Slides:



Advertisements
Similar presentations
PHT 381 Lab # 6. Bacterial population count Many bacteriological studies require that we are able to determine the number of m.o per unit volume of a.
Advertisements

Microbiological Methods
 The beaker is used to measure and pour “non-exact”, or approximate amounts of liquids. Liquids may also be heated in a beaker. The most common unit is.
Lab Equipment. Erlenmeyer Flask Erlenmeyer flasks hold solids or liquids that may release gases during a reaction or that are likely to splatter if stirred.
Lab Equipment. Erlenmeyer Flask Erlenmeyer flasks hold solids or liquids that may release gases during a reaction or that are likely to splatter if stirred.
ENUMERATION OF MICROORGANISMS
E. Coli What's in your water?. Have you ever wondered what is in your water?
How To Prepare, Sterilize, AND Test Culture Media
FIGURE 26.1 Large Stirrer Flask. Large stirrer flask (5 L) on a magnetic stirrer. Note the offset pendulum that makes an excursion in the annular depression.
FIGURE 24.1 Confluent Feeder Layers. Confluent feeder layers can be prepared by seeding cells at a high density or by allowing a normally contact inhibited.
Islamic University _Gaza Department of Biotechnology
An Erlenmeyer Flask is a cone- shaped container with neck, so you can hold the flask or attach a clamp or use a stopper. They are used to measure, mix,
Environmental conditions of animal cell culture part 5 By : Saib H Al Owini.
Lab Equipment Introduction. Beaker Function: Provides an approximate measurement of a liquid’s volume in liters (L) or millimeters (mL).
PHT 381 Lab # 6. Bacterial population count Many bacteriological studies require that we are able to determine the number of m.o per unit volume of a.
Introduction to Lab Ex. 19: Enumeration of Bacteria
Scaling up animal cell culture Chapter 9 from ‘The Basics’ = Chapter 26 from ‘Culture of Animal Cell Culture’
Comparing Raw & Pasteurized Milk and Testing Surfaces for Microbial Contamination Hands-on Module Food Safety Scientist Curriculum © 2014 Board of Regents,
Bacterial count.
FIGURE 4. 1 Laminar-Flow Hood
Lab Equipment.
FIGURE 11.1 Total Wet Weight and Yield of Cells per Mouse Embryo. (a) Total wet weight of embryo without placenta or membranes, mean standard deviation.
FIGURE Effect of Humidity on Temperature in Autoclave
Counting Bacteria Filename: CelCount.ppt Hugh B. Fackrell.
Anaerobic Culture Methods Reducing media –Contain chemicals (thioglycollate or oxyrase) that combine O 2 –Heated to drive off O 2.
FIGURE 14.1 Cell Separation by Density. (a) Cells are layered on to a preformed gradient (see Fig. 14.2) and the tube centrifuged. The tube is placed on.
FIGURE 13.1 Clonal Cell Yield. Relationship of the cell yield in a clone to the number of population doublings; for example, 20 doublings are required.
Culturing Yeast Cells on Media. Pre Lab Definitions: Petri Dish: A round, shallow dish used to grow bacteria. Culture: To grow living organisms in a prepared.
M ETHODS FOR GROWING CELLS. C ONDITIONS N ECESSARY FOR G ROWING C ELLS Appropriate nutrients (Media) Appropriate Environmental Conditions (pH, Temp) Adequate.
FIGURE 25.1 Effect of Cell Density on Expression of GFAP in C6 Cells. Flask cultures were grown to different densities, fixed, and stained by immunoperoxidase.
Cell Culture Looking for a perfect one
Bacterial Growth Curve
Growth of bacteria in culture
FIGURE 19.1 Freezing Curve. Record of the fall in temperature in an ampoule containing medium, clipped with five other ampoules on an aluminum cane, enclosed.
FIGURE 5.1 Probability of Contamination. The solid line in the top graph represents variability in technique against a scale of 100 (right-hand axis),
Minibioreactors -> Volumes below 100 ml Characterized by: -> area of application -> mass transfer -> mixing characteristics.
Microbial Count Aim: Count the number of bacterial cells in a provided sample Methods: Total count, Viable count I. Total count This technique involves.
CHAPTER 10 CELL GROWTH AND DIVISION Cell Growth.
Exp. 2 Cell Morphology and Counting
Ch6 Aseptic Technique “Contamination of microorganisms (bacteria, mycoplasma, yeast, fungus) remains a major problem in tissue culture” [see Table 19-1]
Lab Equipment. Beaker Container for stirring, mixing and heating liquids.
Essential Laboratory Equipment for Cell Culture Dr. Khalid Enan DFG-Sponsored Workshop, Assuit University, Egypt 10 Sep 2012.
Lab Equipment Introduction. Goggles & Apron SAFETY and PROTECTION!!!
MIC 303 INDUSTRIAL AND ENVIRONMENTAL MICROBIOLOGY CULTURE MAINTENANCE.
FIGURE 21.1 Clonogenic Assay for Adherent Cells. Cells are trypsinized, counted, and diluted as for monolayer dilution cloning (see Protocol 13.1). The.
Enumeration (determine the numbers of bacteria in a sample) Direct Measurement of Microbial Growth  Microscopic count - the microbes in a measured volume.
General Laboratory supplies
Microbiological Methods
Microbial Growth Growth in Batch Culture
Technology And Engineering
PHT 381 Lab # 6 Bacterial population count.
Tools in the lab Tools you need to know.
Bacterial Count.
Scaling Up Of Monolayer Cells
ACC PRESENTATION.
Lab procedures when handling micro-organisms
ANIMAL CELL CULTURE.
Increase in number of cells, not cell size Populations Colonies
Marine Biotechnology Lab
Science Equipment.
Learning Objectives i Understand the basic aseptic techniques used in culturing organisms. ii Understand the principles and techniques involved in culturing.
النمو والعد البكتيري Microbial growth النمو الجرثومي.
Kouichi Hasegawa, Jordan E. Pomeroy, Martin F. Pera  Cell Stem Cell 
Metode Manual (Bergeys manual of bacteriology) sni.
Lab procedures when handling micro-organisms
Hypertrophic Scar Cells Fail to Undergo a Form of Apoptosis Specific to Contractile Collagen—The Role of Tissue Transglutaminase  Claire Linge, Janette.
Marine Biotechnology Lab
Contribution of Src-FAK signaling to the induction of connective tissue growth factor in renal fibroblasts  A. Graness, I. Cicha, M. Goppelt-Struebe 
Jens Hasskarl, Palanivel Velupillai, Karl Münger 
Adult human endothelial cell enzymatic harvesting
Presentation transcript:

FIGURE 7. 1 Morphology on Feeder Layers FIGURE 7.1 Morphology on Feeder Layers. Morphological alteration in cells growing on feeder layers: Fibroblasts from human breast carcinoma (a) growing on plastic and (b) growing on a confluent feeder layer of fetal human intestinal cells (FHI). Epithelial cells from human breast carcinoma growing (c) on plastic and (d) on same confluent feeder layer as in (b).

FIGURE 7. 2 Cell Yield and Surface Area FIGURE 7.2 Cell Yield and Surface Area. Relationship of volume of medium and cell yield to the surface area of a culture vessel. The graph is plotted on the basis of the volume of the medium for each size of vessel and is nonlinear, as smaller vessels tend to be used with proportionally more medium than is used with larger vessels. The cell yield is based on the volume of the medium and is approximate.

FIGURE 7. 3 Multiwell Plates FIGURE 7.3 Multiwell Plates. Six-well, 24-well, and 96-well (microtitration) plates. Plates are available with a wide range in the number of wells, from 4 to 144 (see Table 7.2 for sizes and capacities).

FIGURE 7. 4 Petri Dishes. Dishes of 3. 5-, 5-, and 9-cm diameter FIGURE 7.4 Petri Dishes. Dishes of 3.5-, 5-, and 9-cm diameter. Square Petri dishes are also available, with dimensions 9 × 9 cm. A grid pattern can be provided to help in scanning the dish—for example, in counting colonies—but can interfere with automatic colony counting.

FIGURE 7.5 Plastic Flasks. Sizes illustrated are 10 and 25 cm2 (Falcon, BD Biosciences), 75 cm2 (Corning), and 185 cm2 (Nalge Nunc) (see Table 7.2 for representative sizes and capacities).

FIGURE 7. 6 Multisurface Flask FIGURE 7.6 Multisurface Flask. The Nunc Triple-Flask with three 80-cm2 growth surfaces that are seeded simultaneously. Although the growth surface is 240 cm2, the shelf space is equivalent to a regular 80-cm2 flask (See also Corning HyperFlask, Fig. 26.9). As the head space for gas phase is smaller, this flask is best used with a filter cap in a CO2 incubator (arrow). (Photograph courtesy of Nalge Nunc International.)

FIGURE 7.7 Stirrer Flasks. Four small stirrer flasks (Techne), 500-mL capacity, with 250 mL medium, on four-place stirrer rack (see also Figs. 12.5, 26.1, 26.2). (Courtesy of Sterilin.)

FIGURE 7. 8 Venting Petri Dishes and Flasks. (a) Vented Petri dish FIGURE 7.8 Venting Petri Dishes and Flasks. (a) Vented Petri dish. Small ridges, 120 apart, raise the lid from the base and prevent a thin film of liquid (e.g., condensate) from sealing the lid and reducing the rate of gas exchange. (b) Gas-permeable cap on 10-cm2 flask (Falcon, BD Biosciences). °

FIGURE 7. 9 Screw-Cap Vials and Flasks FIGURE 7.9 Screw-Cap Vials and Flasks. (a) Glass flasks are suitable for replicate cultures or storage of samples, particularly when plastic may not survive downstream processing. Screw caps are preferable to stoppers, as they are less likely to leak, and they protect the neck of the flask from contamination. (b) Scintillation vials are particularly useful for isotope incorporation studies but should not be reused for culture after containing scintillation fluid.

FIGURE 7. 10 Nonrandom Growth FIGURE 7.10 Nonrandom Growth. Examples of ridges seen in cultured monolayers in dishes and flasks, probably due to resonance in the incubator from fan motors or to opening and closing of the incubator doors. (Courtesy of Nunc.)

FIGURE 7. 11 Hollow Fiber Culture FIGURE 7.11 Hollow Fiber Culture. A bundle of hollow fibers of permeable plastic is enclosed in a transparent plastic outer chamber and is accessible via either of the two side arms for seeding cells and collecting high molecular weight product. During culture the chamber is perfused from a reservoir, via a gas exchanger and peristaltic pump, down the center of the hollow fibers through connections attached to either end of the chamber. (Courtesy of FiberCell, Inc.; see also Fig. 26.6; Plate 24.)