Results obtained with large mass surface sensitive detectors Zaragoza -November 7, 2005 University of Insubria - Como, Italy INFN - Milano, Italy.

Slides:



Advertisements
Similar presentations
CBM Calorimeter System CBM collaboration meeting, October 2008 I.Korolko(ITEP, Moscow)
Advertisements

Surface Sensitive Bolometers (SSB): last development MARISA PEDRETTI INFN - Milano.
GEANT4 Simulations of TIGRESS
Study of plastic scintillators for fast neutron measurements
Stefano Pirro, IDEA Meeting –Milano November Status of the scintillating bolometer program Scintillating Bolometers Background rejection capabilities.
Activity for the Gerda-specific part Description of the Gerda setup including shielding (water tank, Cu tank, liquid Nitrogen), crystals array and kapton.
Present and future activities of the Garching group (E15)
From CUORICINO to CUORE: To probe the inverted hierarchy region On behalf of the CUORE collaboration DUSL Meeting, Washington DC November 2,-4, 2007 Frank.
Daniel Lenz, University of Wisconsin, Madison 11/05/ APS DNP Cryogenic search for neutrinoless double beta decay Daniel Lenz on behalf of the CUORE.
MQXF state of work and analysis of HQ experimental current decays with the QLASA model used for MQXF Vittorio Marinozzi 10/28/
On the Accuracy of Modal Parameters Identified from Exponentially Windowed, Noise Contaminated Impulse Responses for a System with a Large Range of Decay.
Proposal for high sensitive measurements of 238 U and 232 Th with NAA Ezio Previtali INFN Sez. Milano Milano-Bicocca University ILIAS: JRA1 3rd General.
LNGS Capelli Silvia on behalf of CUORE Collaboration
Stefano Pirro LRT-2004 Sudbury December 13, 2004 Cleanliness backgrounds and surface contaminations in Cuore Stefano Pirro INFN-Milano.
CUORICINO and CUORE Chiara Brofferio Università di Milano – Bicocca and INFN, Sez. di Milano NOW 2004 – Otranto 12 – 17 September 2004 On behalf of the.
First neutrinoless double beta decay results from CUORE-0
Performance test of STS demonstrators Anton Lymanets 15 th CBM collaboration meeting, April 12 th, 2010.
Underground Crystal Growth Natural division TeO 2 growth Ge growth A. Giuliani / J. Morales  For Ge, cosmogenics is very critical  For Te, role of cosmogenics.
LUCIFER a potentially background-free approach to the search for 0  Claudia Nones CSNSM/CNRS-Orsay NOW2010 – September 4 th - 11 th, 2010 – Conca Specchiulla,
From Cuoricino to CUORE: towards the inverted hierarchy region Andrea Giuliani On behalf of the CUORE collaboration University of Insubria (Como) and INFN.
Annual Modulation Study of Dark Matter Using CsI(Tl) Crystals In KIMS Experiment J.H. Choi (Seoul National University) SUSY2012, Beijing.
Double beta decay search with TeO 2 bolometers Andrea Giuliani on behalf of the CUORE collaboration University of Insubria (Como) and INFN Milano-Bicocca.
Stefano Pirro, IDEA Meeting -Zaragoza November 7, Nd Project High Temperature Thermistors News about NdGaO 3 Scintillating Bolometers Conclusions.
THE CUORE EXPERIMENT: A SEARCH FOR NEUTRINOLESS DOUBLE BETA DECAY Marco Andrea Carrettoni on behalf of the CUORE collaboration 2 nd International Conference.
Underground Crystal Growth Marisa Pedretti. Participants INFN (ITALY) LNGS Como Milano-Bicocca Contractor Lawrence Berkeley National Laboratory University.
JRA2 - IDEA Zaragoza, Andrea Giuliani University of Insubria (Como) and INFN - Milano.
Chapter 4 Electron Configurations. Early thoughts Much understanding of electron behavior comes from studies of how light interacts with matter. Early.
Acoustic Emission Testing. Activity of AE Sources in Structural Loading AE Sources Non-metallic inclusions Cracks Frequency range 100 – 500kHz Activity.
SNS neutron background measurements using a portable 3 He LPSD detector.
Present status of CUORE / CUORICINO Andrea Giuliani Università dell’Insubria and INFN Milano 3rd IDEA meeting, Orsay, April 14 – 15, 2005.
Mechanical Status of EUDET Module Marc Anduze – 05/04/07.
Surface events suppression in the germanium bolometers EDELWEISS experiment Xavier-François Navick (CEA Dapnia) TAUP Sendai September 07.
Design Optimization of Toroidal Fusion Shield  Fusion Theory [BLAHBLAHBLAH] Fusion energy production is based on the collision nuclei in a deuterium and.
JRA2 - IDEA Prague, 20/04/2006 Andrea Giuliani University of Insubria (Como) and INFN - Milano.
Status of Surface Sensitive Bolometers University of Insubria – Como, Italy INFN – Milano, Italy Prague, Chiara Salvioni.
The CUORE experiment Thomas Bloxham Lawrence Berkeley National Lab PHENO 2011 May 9th 2011.
Víctor M. Castillo-Vallejo 1,2, Virendra Gupta 1, Julián Félix 2 1 Cinvestav-IPN, Unidad Mérida 2 Instituto de Física, Universidad de Guanajuato 2 Instituto.
BES-III Workshop Oct.2001,Beijing The BESIII Luminosity Monitor High Energy Physics Group Dept. of Modern Physics,USTC P.O.Box 4 Hefei,
Half Day IoP Meeting: Neutrinoless Double Beta Decay, University College London, Great Britain The GERDA Experiment at Gran Sasso Grzegorz Zuzel.
Results from particle beam tests of the ATLAS liquid argon endcap calorimeters Beam test setup Signal reconstruction Response to electrons  Electromagnetic.
Véronique SANGLARD Université de Lyon, UCBL1 CNRS/IN2P3/IPNLyon Status of EDELWEISS-II.
Muon and Neutron Backgrounds at Yangyang underground lab Muju Workshop Kwak, Jungwon Seoul National University 1.External Backgrounds 2.Muon.
Stefano Pirro – NuMass 2010 Stefano Pirro Double beta decay searches with enriched and scintillating bolometers - Milano - Bicocca The Future of Neutrino.
BACKGROUND REJECTION AND SENSITIVITY FOR NEW GENERATION Ge DETECTORS EXPERIMENTS. Héctor Gómez Maluenda University of Zaragoza (SPAIN)
00 Cooler CSB Direct or Extra Photons in d+d  0 Andrew Bacher for the CSB Cooler Collaboration ECT Trento, June 2005.
Claudia Nones CEA/IRFU/SPP GDR Neutrino Meeting – Saclay – 4/11/15 The bolometric way towards the inverted hierarchy of the neutrino mass: CUORE-0 → CUORE.
The COBRA Experiment Jeanne Wilson University of Sussex, UK On behalf of the COBRA Collaboration TAUP 2007, Sendai, Japan.
GERDA – a Search for Neutrinoless Double Beta Decay MPI für Physik, München Neutrinoless double beta decay and the GERDA experimentThe detector array and.
Initial Results from the Scintillator Fast Lost Ion Probe D. Darrow NSTX Physics Meeting February 28, 2005.
SrCl 2 crystal for EC/  + search Presented by J.H. So (KNU)
A Simple Monte Carlo to understand Cerenkov photons propagation and light collection in a single crystal equipped with two PMs Alessandro Cardini / INFN.
1 CRESST Cryogenic Rare Event Search with Superconducting Thermometers Jens Schmaler for the CRESST group at MPI MPI Project Review December 14, 2009.
Chapter 4 Electron Configurations. Waves Today scientists recognize light has properties of waves and particles Waves: light is electromagnetic radiation.
Scintillating Bolometers – Rejection of background due to standard two-neutrino double beta decay D.M. Chernyak 1,2, F.A. Danevich 2, A. Giuliani 1, M.
SIMULATION OF BACKGROUND REDUCTION TECHNIQUES FOR Ge DBD DETECTORS Héctor Gómez Maluenda. University of Zaragoza. GERDA/Majorana MC Meeting.
Marc Anduze – EUDET Meeting – PARIS 08/10/07 Mechanical R&D for EUDET module.
A Study of Reverse MC and Space Charge Effect Simulation with Geant4
From Edelweiss I to Edelweiss II
Status of ULE-HPGe Experiment for WIMP Search in YangYang
ArchPbMoO4 scintillating bolometers as detectors to search for neutrinoless double beta decay of 100Mo Serge Nagorny INFN – Gran Sasso Science Institute,
The COBRA Experiment: Future Prospects
The CUORE experiment Marisa Pedretti INFN Milano Bicocca.
Idee per lo sviluppo del Charge Identifier
From Cuoricino to CUORE: approaching the inverted hierarchy region
Measurement of surface radioactivity by Alpha/Beta detection
Scintillating Bolometers for Double Beta Decay
Serge Nagorny – GSSI-INFN
Sr-84 0n EC/b+ decay search with SrCl2 crystal
CsI Compton Veto Detector for A low Mass WIMP Experiment
Quantum Theory.
Presentation transcript:

Results obtained with large mass surface sensitive detectors Zaragoza -November 7, 2005 University of Insubria - Como, Italy INFN - Milano, Italy

Surface background in CUORE Surface background in CUORE CUORE –  of 130 Te Q  = keV Cuoricino background analysis and Monte Carlo simulations allow to make predictions on the future background expected for CUORE… From what we know until now, experimental data and simulations suggest that the main contribute expected for CUORE background in the DBD region could be:  and degraded particles emitted by 238 U and 232 Th surface contaminations on the Cu frame BKG = 0.18±0.01 c/(keV kg y) T 1/2  > 2× % C.L.  130 Te

Surface background reduction Surface background reduction There are three possible ways to reduce the background due to surface Cu contaminations: Minimizing the amount of Cu surface facing the detectors Improving the quality of surface treatment for Cu components Creating new types of detectors able to recognize surface events This can be done by shielding a bolometer with layers of different materials. Each layer is an auxiliary bolometer… …thermally coupled to a “classical” bolometer. This detector is a Surface Sensitive Bolometer (SSB)

Dynamic behaviour of SSBs Dynamic behaviour of SSBs TeO 2 main bolometer Active shield Classic pulse Fast and high pulse Event originating inside the main bolometer (DBD event) Event originating outside the main bolometer (degraded ) The origin of events can be determined. The addition of active shields alters the dynamic behaviour of the bolometer, leading to pulses different in both amplitude and shape. An -surface event gives distinct pulses on the thermistors of the SSB. Particles releasing energy in the detector heat up each element of this composite bolometer:

Identification of surface events – Amplitude (1) Identification of surface events – Amplitude (1) Surface events may be identified comparing pulse amplitudes read simultaneously by the thermistor on the main absorber and on the active shield. The main tool is a graph reporting the pulse height from the shield sensor vs the pulse height from the main sensor. SCATTER PLOT Amplitude on active shield sensor [mV] Amplitude on main absorber sensor [mV] A DBD event occurring inside the absorber gives an equal amplitude pulse on both sensors An  particle coming from outside the detector gives a higher amplitude pulse on the shield sensor than on the main sensor

Various materials for active shields were tested on small size detectors (main absorbers 2×2×2 - 2×2×0.5 cm 3 ) Surface events TeO 2 shields Pros Low cost Cons Low purity Notes IET Si slabs (Polish) gave good results IRST Si slabs (Italian) gave some unexplained results Pros Thermal contractions with main absorber Known material Cons Frailty Thermal coupling with thermistors SSB Como SSB Como Ge shieldsSi shields Pros Excellent results High purity Cons High cost Surface events Parallel readout!

Identification of surface events – Rise time (2) Identification of surface events – Rise time (2) Not just pulse amplitude discrimination But also pulse shape discrimination Counts Rise time on active shield thermistor [ms] Surface events correspond to pulses with shorter rise times on the shield sensor Two classes of events Rise time discrimination is a powerful tool to isolate outer events

Preparation for the large mass test Preparation for the large mass test After testing a great deal of SSB prototypes, a test with CUORE real size crystals was organized. TeO 2 crystals, size 5×5×5 cm 3, m=750 g Main absorber Si slabs produced by IRST, size 5×5×0.3 cm 3, resistivity 20kΩ (floating zone crystal with < atoms/cm 3 of P) Active shields Initial idea for the active shields: TeO 2. However, the producer could not deliver slabs in time for the beginning of assembly. Therefore… Four SSBs with these characteristics were assembled. Slab sensors connected in parallel configuration Signal readout Moreover, in order to reduce the number of necessary channels…

LNGS – Single SSB LNGS – Single SSB Two configurations - 3 detectors type A, 1 detector type B Type AType B Very different from both a thermal and a mechanical point of view Slabs thermally coupled to absorbers through Ge stand-offs; teflon holders keeping crystals attached to the Cu frame.

LNGS – Four detectors module LNGS – Four detectors module The four SSB module (Cu frame and PTFE holders)… …and the whole structure mounted in the cryostat (along with other eight nude crystals for an assembly test).

LNGS - Problems LNGS - Problems Only two crystals were firmly held. Crystals with unequal heights The fully covered crystal (even if its height was increased by PTFE holding it through the slabs) was not securely fixed. The last one was not held at all. Slabs not fully realiable Si slabs by IRST had previously lead to results whose physical origin has yet to be determined. Difficult assembly Because of very different thermal contractions between Si and TeO 2, slabs must be glued only close to the center of the TeO 2 crystal face. Many slabs detached during assembly and had to be provisionally attached with vacuum grease. Lost signals During the test, we lost contact with a set of slab sensors in parallel: signals from one SSB could not be acquired. A lot of problems, but in spite of them… The two firmly held crystals worked properly and one of them had readable slabs, from which we gathered data.

LNGS – Scatter plot LNGS – Scatter plot The scatter plot is coherent with the expected behaviour. Surface events Bulk events Mixed events However, there are some problems. For example… There is a considerable contamination ( in the slabs or close to them. This is probably a slab with a bad thermal coupling to the absorber. While surface events may be identified, the parallel configuration seems to confuse the physical understanding of each element in the plot.

LNGS – Rise time distribution on shields LNGS – Rise time distribution on shields Again as expected, we can recognize various classes of events from the rise time distribution on the parallel slabs channel. Rise time vs amplitude plot on slab sensors:

Surface events & decay time on main crystal Surface events & decay time on main crystal Surprise: there is another way to distinguish surface events from bulk events. Decay time – amplitude relation on main absorber sensor Detector with no slabsDetector with slabs

Identification of surface events – Decay time (3) Identification of surface events – Decay time (3) Bulk events are well isolated by a cut in the decay time – amplitude plot on the main sensor

Shields as pulse shape modifiers Shields as pulse shape modifiers Shields act as pulse shape modifiers – behaviour to be investigated in the future. We found a similar feature in the previous tests at Como. Important feature… Is it possible to get rid of the slab sensors? In this way, slabs could be a very promising option for CUORE.

Background reduction Background reduction Cutting on the DT distribution allows to isolate a great deal of unwanted events. Quantitatively – background obtained region) E [MeV] ± ± ± ± ± 0.08 Bkg (no slabs) [c/kg keV y] Bkg (slabs) [c/kg keV y] 0.44 ± 0.06 The  region shows a considerable improvement: the obtained value is very similar to the Cuoricino value. Important result: even though the test was not performed in extremely clean conditions, the background is comparable to that obtained with accurately cleaned detectors… Rejection by slabs works

Conclusions & future investigations Conclusions & future investigations Not complete efficiency of the SSB rejection (high contamination, not working slabs) Next test at LNGS Four detectors with TeO 2 slabs (problem of thermistor coupling to be solved) Careful cleaning of all the detectors Single readout of the slab sensors of two detectors (instead of parallel) “Passive” slabs for the other two detectors (can we use just the main absorber sensor?) Origin of the decay time distribution on the main absorber sensor and reproducibility of surface events identification with this parameter Topics to be cleared by analysis & future tests Motivation for the background value (~ 0.2 c/kg keV y): SSBs are proving themselves to be very helpful in understanding the nature of the background.