1. 2 Contents The “Tsubame” Project Description of Hard X-ray Polarimeter (HXCP) Results of X-ray Beam Test Summary.

Slides:



Advertisements
Similar presentations
Compton integrating method Beam test summary PREX/Happex Collaboration Meeting Alexandre Camsonne.
Advertisements

RHESSI Studies of Solar Flare Hard X-Ray Polarization Mark L. McConnell 1, David M. Smith 2, A. Gordon Emslie 4, Martin Fivian 3, Gordon J. Hurford 3,
ASTROSAT LAXPC Biswajit Paul Raman Research Institute, Bangalore On behalf of the LAXPC Team.
Evolving X-ray Polarimetry towards high energy and solar science Sergio Fabiani Università degli Studi di Roma “Tor Vergata” INAF / IAPS I A P S Istituto.
1 T. Mizuno et al. August 23, 2014 HEAPA Symposium on Future T. Mizuno (Hiroshima Univ.) on behalf of the SGD team and Polarization team.
The PHENEX Experiment Results in 2006 and Future Plan S. Gunji* a, Y. Kishimoto a,H. Sakurai a, F. Tokanai a, M. Kanno a, Y. Ishikawa a, Hayashida b, N.
IEEE_2007Nov.ppt Tsunefumi Mizuno 1 High Sensitivity Balloon-Borne Hard X-Ray/Soft Gamma-Ray Polarimeter PoGOLite November 2 nd, 2007 IEEE Nuclear Science.
X-ray polarisation: Science
Statistical Properties of GRB Polarization
Space Applications of Geant4 Polarized Processes F.Longo + G.Depaola * + University of Ferrara and INFN (Italia) * National University of Córdoba (Argentina)
Terrestrial Gamma-ray Flashes. Gamma Ray Astronomy Beginning started as a small budget research program in 1959 monitoring compliance with the 1963 Partial.
RHESSI Studies of Solar Flare Hard X-Ray Polarization Mark L. McConnell 1, David M. Smith 2, A. Gordon Emslie 4, Martin Fivian 3, Gordon J. Hurford 3,
China’s Future Missions in Space High Energy Astrophysics Shuang Nan Zhang 张双南 Tsinghua University and Institute of High Energy Physics, Chinese Academy.
DOE Review (June 3, 2004) PoGO by T.Kamae 1 Large-Area Balloon-Borne Polarized Gamma Ray Observer (PoGO) DOE Review (June 3, 2004) Tune Kamae for the PoGO.
Science Specification Table 12 keV keV for neutral particles 40.5 cm 2 image plane Electronic Noise 3 keV FWHM Proton Dead Layer
PoGOandGlast_ ppt 1 Hard X-ray Polarimeter PoGO and GLAST mission ( 硬 X 線偏光観測 PoGO 計画と GLAST との連携 ) November 25, 2005, GLAST Science Workshop.
X-ray Polarimetry with gas proportional counters through rise-time K. Hayashida, T. Horikawa, Y. Nakashima, H. Tsunemi (Osaka University, Japan)
Past, present and future of hard X-ray/γ-ray measurements of GRB polarization P. Laurent P. Laurent CEA/DSM/IRFU/SAP & APC CEA/DSM/IRFU/SAP & APC June,
Radiation Detection and Measurement, JU, First Semester, (Saed Dababneh). 1 Spectrum if all energy is captured in detector. Allows identification.
INSTR-08, BINP, Novosibirsk 1 Belle calorimeter upgrade B.Shwartz, Budker Institute of Nuclear Physics Novosibirsk on behalf of BELLE calorimeter.
The PEPPo e - & e + polarization measurements E. Fanchini On behalf of the PEPPo collaboration POSIPOL 2012 Zeuthen 4-6 September E. Fanchini -Posipol.
1 Performance of multi-anode PMT employing an ultra bi-alkali photo-cathode and rugged dynodes Takahiro Toizumi Tokyo Institute of Technology S. Inagwa.
RELEC project (Relativistic ELECtrons). Unified platform “Karat” for small spacecraft 2 MICROSATELLITE KARAT FOR PLANETARY MISSIONS, ASTROPHYSICAL AND.
The Hard X-ray Modulation Telescope Mission
Data Acquisition System of the PoGOLite Balloon Experiment Hiromitsu TAKAHASHI (Hiroshima University) M. Matsuoka,
Gamma-Ray Burst Polarimeter – GAP – aboard the Solar Powered Sail Mission Gamma-Ray Burst Polarimeter – GAP – aboard the Solar Powered Sail Mission Daisuke.
© Daisuke YONETOKU (Kanazawa Univ.) Daisuke YONETOKU (Kanazawa Univ.) Toshio MURAKAMI (Kanazawa Univ.) Shuichi GUNJI ( Yamagata Univ. ) Tatehiro MIHARA.
DEPARTEMENT DE PHYSIQUE NUCLEAIRE ET CORPUSCULAIRE POLAR POLAR: A novel X-ray polarimeter Daniel Haas ISDC Versoix ECRS 2008 Kosice, Slovakia Outline GRBs.
1 Report on analysis of PoGO Beam Test at Spring-8 Tsunefumi Mizuno July 15, 2003.
Setup for hypernuclear gamma-ray spectroscopy at J-PARC K.Shirotori Tohoku Univ. Japan for the Hyperball-J collaboration J-PARC E13 hypernuclear  -ray.
CZT Imager for ASTROSAT CONFIGURATION. CZT Module.
Gamma-Ray Bursts observed with INTEGRAL and XMM- Newton Sinead McGlynn School of Physics University College Dublin.
Hard X and Gamma-ray Polarization: the ultimate dimension (ESA Cosmic Vision ) or the Compton Scattering polarimetery challenges Ezio Caroli,
2000/11/101 X-ray polarimetry experiment with balloon borne gas proportional counters K.Hayashida, H. Tsunemi, T. Koike, T. Horikawa (Osaka University),
PoGO_G4_ ppt1 Study on Key Properties of PoGO by Geant4 Simulator January 28, 2004 Tsunefumi Mizuno History of changes:
We report the result of a beam test on a prototype of Astronomical hard X-ray/soft gamma-ray Polarimeter, PoGO (Polarized Gamma-ray Observer). PoGO is.
1 Report on analysis of PoGO Beam Test at Spring-8 Tsunefumi Mizuno July 15, 2003 July 21, 2003 revised August 1, 2003 updated.
Hard X-ray Polarimeter for Small Satellite Design, Feasibility Study, and Ground Experiments K. Hayashida (Osaka University), T. Mihara (RIKEN), S. Gunji,
X-ray Polarimetry with gas proportional counters through rise-time
Electron Detection for Compton Polarimetry Michael McDonald Outline -Compton Effect -Polarimetry -Detectors -Diamond Results.
Monte Carlo Simulation Study of In-orbit Background for the Soft Gamma-ray Detector onboard ASTRO-H Mizuno T., Hiragi K., Fukazawa Y., Umeki Y. (Hiroshima.
Nov Beam Catcher in KOPIO (H. Mikata Kaon mini worksyop1 Beam Catcher in the KOPIO experiment Hideki Morii (Kyoto Univ.) for the KOPIO.
Polarization Characteristic of Multi-layer Mirror for Hard X-ray Observation of Astrophysical Objects T. Mizuno 1, J. Katsuta 2, H. Yoshida 1, H. Takahashi.
A. Zelenski a, G. Atoian a *, A. Bogdanov b, D.Raparia a, M.Runtso b, D. Steski a, V. Zajic a a Brookhaven National Laboratory, Upton, NY, 11973, USA b.
? At Yangyang beach, looking for something in the swamp of particles and waves. 1 The recent results from KIMS Seung Cheon Kim (Seoul National University)
A Prototype Diamond Detector for the Compton Polarimeter in Jefferson lab, Hall C Medium Energy Physics Group Amrendra.
PoGO_collimator_ ppt1 Study of PoGO background dependence on the collimator material/slow scintillator threshold April 21, 2004 Tsunefumi Mizuno.
1 First Results of the SLD Cerenkov Polarimeter at the DESY test beam Oleg Eyser Daniela K äfer, Christian Helebrant, Jenny List, Ulrich Velte*
MPI Semiconductor Laboratory, The XEUS Instrument Working Group, PNSensor The X-ray Evolving-Universe Spectroscopy (XEUS) mission is under study by the.
PoGO_G4_ ppt1 Study of optimized fast scintillator length for the astronomical hard X- ray/soft gamma-ray polarimeter PoGO November 1, 2004 Tsunefumi.
PoGO_G4_ ppt1 Study of BGO/Collimator Optimization for PoGO August 8th, 2005 Tsunefumi Mizuno, Hiroshima University/SLAC
PoGOLiteMC_ ppt 1 Updated MC Study of PoGOLite Trigger Rate/BG January 30, 2007 Tsunefumi Mizuno (Hiroshima Univ.)
ArgonneResult_ ppt1 Comparison of data and simulation of Argonne Beam Test July 10, 2004 Tsunefumi Mizuno
2001/9/111 X-ray polarimetry with balloon borne gas proportional counters K.Hayashida, H. Tsunemi, T. Horikawa, Y. Nakashima (Osaka University, Japan),
Development of the X-ray Detectors for XTP Cao Xue-lei Institute of High Energy Physics, CAS IHEP, Beijing.
ArgonneResult_ ppt1 Results of PoGO Argonne Beam Test PoGO Collaboration meeting at SLAC, February 7, 2004 Tsunefumi Mizuno
1 Report on analysis of PoGO Beam Test at Spring-8 Tsunefumi Mizuno July 15, 2003 July 21, 2003 revised.
O Tsunefumi Mizuno, Tuneyoshi Kamae, Jonny Ng, Hiroyasu Tajima (SLAC), John W. Mitchell, Robert Streitmatter (NASA GSFC), Richard C. Fernholz, Edward Groth.
For the 11th IACHEC meeting , Pune, India POLAR status and beam test with ESRF in 2015 Bobing WU Institute of High Energy Physics, CAS On behalf.
X-ray Polarimeter - POLIX: Design and development status
POLAR: a Gamma-Ray Burst Polarimeter onboard the Chinese Spacelab
Dark Matter Search With an Ultra-low Threshold Germanium Detector proposed by Tsinghua University Seoul National University Academia Sinica Qian Yue.
June 1, 2004 Tsunefumi Mizuno Expected Modulation Factor of PoGO calculated with Geant4 Simulator with PoGO-fix June 1, 2004 Tsunefumi.
WPOL Wide field camera with POLarimetry
Development of Hard X-ray Detector with GEM
ScECAL+AHCAL+TCMT Combined Beam FNAL
Detector R&D in KAPAC Outline Compton Camera SOI detector
Gamma Ray Satellites Simulations with Geant4
Background Reduction for Quantitative Gamma-ray Imaging with the Electron-Tracking Compton Camera in High Dose Areas May 26th, PS10A-10 T. Mizumoto,
First demonstration of portable Compton camera to visualize 223-Ra concentration for radionuclide therapy Kazuya Fujieda (Waseda University) J. Kataoka,
Presentation transcript:

1

2 Contents The “Tsubame” Project Description of Hard X-ray Polarimeter (HXCP) Results of X-ray Beam Test Summary

3 Tsubame is the 4 th very small satellite in Tokyo Tech. Cube-Sat Project in Tokyo Tech We have been working on cube sat projects since 2001~ CUTE I(2003) Cute1.7+APD(2006) Cute1.7+APD II (2008) Tsubame Re-Entered In Operation ・ Dimension: 50 x 50 x 50 cm 3 ・ Total Mass: 50 kg ・ Attitude Control: 4 CMGs (6 degrees/s) ・ Launch: Early 2013~ Now Developing

4 Observation Sequence 1.Trigger and Localization 2. High Speed Pointing 3. Observation (<15 s after the trigger) Hard X-ray Compton Polarimeter Wide-field Burst Monitor Science Instruments of the Tsubame For “Real time” and “Automatic” polarimetry, Two detector systems are onboard. Wide-field Burst Monitor (FoV: 2π str) → Detection and Localization Hard X-ray Compton Polarimeter → Polarimetry at keV energy band

5 Hard X-ray Compton Polarimeter Plastic scintillator CsI(Tl) scintillator ・ Detection principle : anisotropy of the Compton scattering ・ Performance Effective area : 7 cm 100 keV ( Physical area: 36cm 2 ) Modulation Factor: 47.8 ±0.9 % Minimum Detectable Pol.(3σ): 6.2 % (3.2x10 -5 erg/cm 2 MAPMT APD η Polarized direction

6 Development of prototype polarimeter ・ Two types of ASIC ・ ADCs triggered by coincidence Plastic array MAPMT IFC APD CsI array ASIC for PMT ADC Plastic array CsI array MAPMTAPD trigger data hold ASIC for PMT ASIC for APD Interface Card(IFC) Prototype polarimeter for beam test ・ Plastic 16 units, CsI 16 units (Partial model of 1 PMT + 16 APDs) CsI array APD ASIC for APD Geometry of the Detector plastic CsI ~20 cm ASIC for APD Data bus (outside)

7 Polarized Beam ・ 2009/Dec/20th ~ Dec/24th ・ Tsukuba, Japan) Photon Factory (PF) BL 14A Polarimeter Equatorial mount 90 % polarized 82.5 keV X-ray beam Attenuator (Tungsten-foil) Setup Image Polarized X-ray beam Rotated per 45 degree Polarized direction

8 Obtained Spectra Spectrum of the recoil electrons detected by Plastic (PMT) Spectrum of Scattered photons detected by CsI(Tl) (APD) Deposit Energy [keV] Total energy (keV) Compton event Deposit Energy (keV) Total energy (keV) Extracting Compton events Photon Energy [keV] Coutns Compton Photo- electric abs. noise 10 1

9 Making the modulation curve of polarization Beam test MF = 72.3 ± 5.4 % The beam test result seems consistent with the simulation Azimuth Angle [deg] Counts Simulation MF = 68.7 ± 1.2 % Polarized direction 0° All data are combined Reducing systematic error

10 Plastic CsI APD Data processing boards HV module Passive Shield PMT We are now developing Engineering Model ASIC for APDs Passive Shield ( W, Sn, Pb ) HV module Data processing boards Lighter ( ~ 4 kg/unit)

11 Summary We are now developing the small satellite Tsubame to be launched after 2013 To measure the polarization of GRBs Expecting significant detection of X-ray polarization for 6 GRBs/yr. Evaluation of the performance of the polarimeter by irradiating polarized X-ray The results are consistent with the simulation Manufacturing the EM of polarimeter based on prototype